Outcome prediction of cardiac arrest with automatically computed gray-white matter ratio on computed tomography images

被引:1
|
作者
Tsai, Hsinhan [1 ]
Chi, Chien-Yu [2 ]
Wang, Liang-Wei [2 ]
Su, Yu-Jen [2 ]
Chen, Ya-Fang [3 ]
Tsai, Min-Shan [2 ]
Wang, Chih-Hung [2 ]
Hsu, Cheyu [4 ]
Huang, Chien-Hua [2 ]
Wang, Weichung [5 ]
机构
[1] Natl Taiwan Univ, Dept Comp Sci & Informat Engn, Taipei 106216, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Emergency Med, Taipei 100225, Taiwan
[3] Natl Taiwan Univ Hosp, Dept Med Imaging, Taipei 100225, Taiwan
[4] Natl Taiwan Univ Hosp, Dept Oncol, Taipei 100225, Taiwan
[5] Natl Taiwan Univ, Inst Appl Math Sci, Taipei 106216, Taiwan
关键词
CT scan; Gray-white matter ratio; Hypoxic-ischemic encephalopathy; Out-of-hospital cardiac arrest; Prognosis; Return of spontaneous circulation; Clinical decision making; COMATOSE PATIENTS; CARDIOPULMONARY-RESUSCITATION; AUTOMATED ASSESSMENT; PROGNOSTIC VALUES; CLINICAL PAPER; CT; ASSOCIATION; PERFORMANCE; GUIDELINES; EDEMA;
D O I
10.1186/s13054-024-04895-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background This study aimed to develop an automated method to measure the gray-white matter ratio (GWR) from brain computed tomography (CT) scans of patients with out-of-hospital cardiac arrest (OHCA) and assess its significance in predicting early-stage neurological outcomes.Methods Patients with OHCA who underwent brain CT imaging within 12 h of return of spontaneous circulation were enrolled in this retrospective study. The primary outcome endpoint measure was a favorable neurological outcome, defined as cerebral performance category 1 or 2 at hospital discharge. We proposed an automated method comprising image registration, K-means segmentation, segmentation refinement, and GWR calculation to measure the GWR for each CT scan. The K-means segmentation and segmentation refinement was employed to refine the segmentations within regions of interest (ROIs), consequently enhancing GWR calculation accuracy through more precise segmentations.Results Overall, 443 patients were divided into derivation N=265, 60% and validation N=178, 40% sets, based on age and sex. The ROI Hounsfield unit values derived from the automated method showed a strong correlation with those obtained from the manual method. Regarding outcome prediction, the automated method significantly outperformed the manual method in GWR calculation (AUC 0.79 vs. 0.70) across the entire dataset. The automated method also demonstrated superior performance across sensitivity, specificity, and positive and negative predictive values using the cutoff value determined from the derivation set. Moreover, GWR was an independent predictor of outcomes in logistic regression analysis. Incorporating the GWR with other clinical and resuscitation variables significantly enhanced the performance of prediction models compared to those without the GWR.Conclusions Automated measurement of the GWR from non-contrast brain CT images offers valuable insights for predicting neurological outcomes during the early post-cardiac arrest period.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] COMPUTED TOMOGRAPHY OF SHEARING INJURIES OF CEREBRAL WHITE MATTER
    ZIMMERMAN, RA
    BILANIUK, LT
    GENNERALLI, T
    RADIOLOGY, 1978, 127 (02) : 393 - 396
  • [42] COMPUTED-TOMOGRAPHY IN WHITE MATTER DISEASES - REPLY
    FARRELL, K
    CHUANG, S
    BECKER, LE
    ANNALS OF NEUROLOGY, 1985, 17 (03) : 315 - 315
  • [43] Predicting Clinical Outcome in Comatose Cardiac Arrest Patients Using Early Noncontrast Computed Tomography
    Wu, Ona
    Batista, Leonardo M.
    Lima, Fabricio O.
    Vangel, Mark G.
    Furie, Karen L.
    Greer, David M.
    STROKE, 2011, 42 (04) : 985 - 992
  • [44] The effect of skull volume and density on differentiating gray and white matter on routine computed tomography scans of the head
    Craddock, Carter
    Chen, Michael Y.
    Dixon, Robert L.
    Schlarb, Christopher A.
    Williams, Daniel W., III
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (05) : 734 - 738
  • [45] Gray Matter-White Matter De-Differentiation on Brain Computed Tomography Predicts Brain Death Occurrence
    Vigneron, C.
    Labeye, V.
    Cour, M.
    Hannoun, S.
    Grember, A.
    Rampon, F.
    Cotton, F.
    TRANSPLANTATION PROCEEDINGS, 2016, 48 (06) : 1893 - 1897
  • [46] Sudden cardiac arrest during computed tomography examination: Clinical findings and "Dense abdominal veins" on computed tomography
    Ko, SF
    Ng, SH
    Chen, MC
    Lee, TY
    Huang, CC
    Wan, YL
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (01) : 93 - 97
  • [47] Brain Computed Tomography After In-Hospital Cardiac Arrest
    Ratay, Cecelia R.
    Callaway, Clifton W.
    Elmer, Jonathan
    Flickinger, Kate
    Coppler, Patrick J.
    CIRCULATION, 2022, 146
  • [48] Evaluating severity of white matter lesions from computed tomography images with convolutional neural network
    Pitkanen, Johanna
    Koikkalainen, Juha
    Nieminen, Tuomas
    Marinkovic, Ivan
    Curtze, Sami
    Sibolt, Gerli
    Jokinen, Hanna
    Rueckert, Daniel
    Barkhof, Frederik
    Schmidt, Reinhold
    Pantoni, Leonardo
    Scheltens, Philip
    Wahlund, Lars-Olof
    Korvenoja, Antti
    Lotjonen, Jyrki
    Erkinjuntti, Timo
    Melkas, Susanna
    NEURORADIOLOGY, 2020, 62 (10) : 1257 - 1263
  • [49] Evaluating severity of white matter lesions from computed tomography images with convolutional neural network
    Johanna Pitkänen
    Juha Koikkalainen
    Tuomas Nieminen
    Ivan Marinkovic
    Sami Curtze
    Gerli Sibolt
    Hanna Jokinen
    Daniel Rueckert
    Frederik Barkhof
    Reinhold Schmidt
    Leonardo Pantoni
    Philip Scheltens
    Lars-Olof Wahlund
    Antti Korvenoja
    Jyrki Lötjönen
    Timo Erkinjuntti
    Susanna Melkas
    Neuroradiology, 2020, 62 : 1257 - 1263
  • [50] A prognostic scoring system for operated acute epidural hematoma based on gray-white matter ratio
    Luo, Yunxing
    He, Xiwu
    Yang, Mingfei
    Du, Chaonan
    Jin, Xiaoqing
    MEDICINE, 2021, 100 (33)