Outcome prediction of cardiac arrest with automatically computed gray-white matter ratio on computed tomography images

被引:1
|
作者
Tsai, Hsinhan [1 ]
Chi, Chien-Yu [2 ]
Wang, Liang-Wei [2 ]
Su, Yu-Jen [2 ]
Chen, Ya-Fang [3 ]
Tsai, Min-Shan [2 ]
Wang, Chih-Hung [2 ]
Hsu, Cheyu [4 ]
Huang, Chien-Hua [2 ]
Wang, Weichung [5 ]
机构
[1] Natl Taiwan Univ, Dept Comp Sci & Informat Engn, Taipei 106216, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Emergency Med, Taipei 100225, Taiwan
[3] Natl Taiwan Univ Hosp, Dept Med Imaging, Taipei 100225, Taiwan
[4] Natl Taiwan Univ Hosp, Dept Oncol, Taipei 100225, Taiwan
[5] Natl Taiwan Univ, Inst Appl Math Sci, Taipei 106216, Taiwan
关键词
CT scan; Gray-white matter ratio; Hypoxic-ischemic encephalopathy; Out-of-hospital cardiac arrest; Prognosis; Return of spontaneous circulation; Clinical decision making; COMATOSE PATIENTS; CARDIOPULMONARY-RESUSCITATION; AUTOMATED ASSESSMENT; PROGNOSTIC VALUES; CLINICAL PAPER; CT; ASSOCIATION; PERFORMANCE; GUIDELINES; EDEMA;
D O I
10.1186/s13054-024-04895-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background This study aimed to develop an automated method to measure the gray-white matter ratio (GWR) from brain computed tomography (CT) scans of patients with out-of-hospital cardiac arrest (OHCA) and assess its significance in predicting early-stage neurological outcomes.Methods Patients with OHCA who underwent brain CT imaging within 12 h of return of spontaneous circulation were enrolled in this retrospective study. The primary outcome endpoint measure was a favorable neurological outcome, defined as cerebral performance category 1 or 2 at hospital discharge. We proposed an automated method comprising image registration, K-means segmentation, segmentation refinement, and GWR calculation to measure the GWR for each CT scan. The K-means segmentation and segmentation refinement was employed to refine the segmentations within regions of interest (ROIs), consequently enhancing GWR calculation accuracy through more precise segmentations.Results Overall, 443 patients were divided into derivation N=265, 60% and validation N=178, 40% sets, based on age and sex. The ROI Hounsfield unit values derived from the automated method showed a strong correlation with those obtained from the manual method. Regarding outcome prediction, the automated method significantly outperformed the manual method in GWR calculation (AUC 0.79 vs. 0.70) across the entire dataset. The automated method also demonstrated superior performance across sensitivity, specificity, and positive and negative predictive values using the cutoff value determined from the derivation set. Moreover, GWR was an independent predictor of outcomes in logistic regression analysis. Incorporating the GWR with other clinical and resuscitation variables significantly enhanced the performance of prediction models compared to those without the GWR.Conclusions Automated measurement of the GWR from non-contrast brain CT images offers valuable insights for predicting neurological outcomes during the early post-cardiac arrest period.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Cranial computed tomography in the resuscitated patient with cardiac arrest
    Naples, Robin
    Ellison, Elizabeth
    Brady, William J.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2009, 27 (01): : 63 - 67
  • [32] Cardiac arrest: radiological findings in abdominal computed tomography
    Fatahi Bandpey, M. L.
    Sanchez Santos, P. J.
    RADIOLOGIA, 2013, 55 (03): : 271 - 273
  • [33] Head computed tomography scan following cardiac arrest
    Joellene R. Mitchell
    Paul Jefferson
    David R. Ball
    Dean D. Bell
    Peter G. Brindley
    Osama Al Muslim
    David Zygun
    Canadian Journal of Anesthesia, 2005, 52 (8): : 892 - 893
  • [34] Head computed tomography scan following cardiac arrest
    Mitchell, JR
    Jefferson, P
    Ball, DR
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2005, 52 (08): : 892 - 892
  • [35] Brain Swelling and Loss of Gray and White Matter Differentiation in Human Postmortem Cases by Computed Tomography
    Shirota, Go
    Gonoi, Wataru
    Ishida, Masanori
    Okuma, Hidemi
    Shintani, Yukako
    Abe, Hiroyuki
    Takazawa, Yutaka
    Ikemura, Masako
    Fukayama, Masashi
    Ohtomo, Kuni
    PLOS ONE, 2015, 10 (11):
  • [36] STATISTICAL-METHOD FOR DETERMINING THE PROPORTIONS OF GRAY-MATTER, WHITE MATTER, AND CSF USING COMPUTED TOMOGRAPHY
    THALER, HT
    FERBER, PW
    ROTTENBERG, DA
    NEURORADIOLOGY, 1978, 16 : 133 - 135
  • [37] White Matter and Gray Matter Segmentation in 4D Computed Tomography (vol 7, 119, 2017)
    Manniesing, Rashindra
    Oei, Marcel T. H.
    Oostveen, Luuk J.
    Melendez, Jaime
    Smit, Ewoud J.
    Platel, Bram
    Sanchez, Clara I.
    Meijer, Frederick J. A.
    Prokop, Mathias
    van Ginneken, Bram
    SCIENTIFIC REPORTS, 2018, 8
  • [38] The role of the gray-to-white matter ratio to predict the prognosis of cardiac arrest treated with ECMO
    Lopez-Herce, Jesus
    Del Castillo, Jimena
    JOURNAL OF THORACIC DISEASE, 2016, 8 (05) : 757 - 761
  • [39] The prognostic value of gray-white-matter ratio in cardiac arrest patients treated with hypothermia
    Michael Scheel
    Christian Storm
    Andre Gentsch
    Jens Nee
    Fridolin Luckenbach
    Christoph J Ploner
    Christoph Leithner
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 21
  • [40] The prognostic value of gray-white-matter ratio in cardiac arrest patients treated with hypothermia
    Scheel, Michael
    Storm, Christian
    Gentsch, Andre
    Nee, Jens
    Luckenbach, Fridolin
    Ploner, Christoph J.
    Leithner, Christoph
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2013, 21