MicroSEC filters sequence errors for formalin-fixed and paraffin-embedded samples

被引:0
|
作者
Masachika Ikegami
Shinji Kohsaka
Takeshi Hirose
Toshihide Ueno
Satoshi Inoue
Naoki Kanomata
Hideko Yamauchi
Taisuke Mori
Shigeki Sekine
Yoshihiro Inamoto
Yasushi Yatabe
Hiroshi Kobayashi
Sakae Tanaka
Hiroyuki Mano
机构
[1] National Cancer Center Research Institute,Division of Cellular Signaling
[2] The University of Tokyo,Department of Orthopaedic Surgery, Faculty of Medicine
[3] Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital,Department of Musculoskeletal Oncology
[4] Kyushu University,Department of Orthopaedic Surgery, Graduate School of Medical Sciences
[5] St Luke’s International Hospital,Department of Pathology
[6] St Luke’s International Hospital,Department of Breast Surgical Oncology
[7] National Cancer Center Research Institute,Division of Molecular Pathology
[8] National Cancer Center Hospital,Department of Hematopoietic Stem Cell Transplantation
[9] National Cancer Center Research Institute,Department of Biobank and Tissue Resources
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The clinical sequencing of tumors is usually performed on formalin-fixed, paraffin-embedded samples and results in many sequencing errors. We identified that most of these errors are detected in chimeric reads caused by single-strand DNA molecules with microhomology. During the end-repair step of library preparation, mutations are introduced by the mis-annealing of two single-strand DNA molecules comprising homologous sequences. The mutated bases are distributed unevenly near the ends in the individual reads. Our filtering pipeline, MicroSEC, focuses on the uneven distribution of mutations in each read and removes the sequencing errors in formalin-fixed, paraffin-embedded samples without over-eliminating the mutations detected also in fresh frozen samples. Amplicon-based sequencing using 97 mutations confirmed that the sensitivity and specificity of MicroSEC were 97% (95% confidence interval: 82–100%) and 96% (95% confidence interval: 88–99%), respectively. Our pipeline will increase the reliability of the clinical sequencing and advance the cancer research using formalin-fixed, paraffin-embedded samples.
引用
收藏
相关论文
共 50 条
  • [21] The quality of DNA isolated from autopsy formalin-fixed and formalin-fixed paraffin-embedded tissues: study of 1662 samples
    Vitosevic, Katarina
    Todorovic, Danijela
    Slovic, Zivana
    Varljen, Tatjana
    Radakovic, Ivana
    Radojevic, Dusan
    Canovic, Vanja
    Todorovic, Milos
    MOLECULAR BIOLOGY REPORTS, 2023, 50 (08) : 6323 - 6336
  • [22] Preparation of Formalin-fixed Paraffin-embedded Tissue for Immunohistochemistry
    Canene-Adams, Kirstie
    LABORATORY METHODS IN ENZYMOLOGY: CELL, LIPID AND CARBOHYDRATE, 2013, 533 : 225 - 233
  • [23] The characterisation of formalin-fixed paraffin-embedded sarcomas using sequence detection assays
    Lewis, FA
    Longfellow, M
    Merchant, W
    Raja, U
    Quirke, P
    JOURNAL OF PATHOLOGY, 2000, 190 : 32A - 32A
  • [24] Proteomic analysis of formalin-fixed, paraffin-embedded melanoma
    Murphy, Michael J.
    Rezaul, Karim
    Phelps, Amanda
    Han, David K.
    JOURNAL OF CUTANEOUS PATHOLOGY, 2012, 39 (04) : 464 - 466
  • [25] Sequence analysis of PCR-amplifications in formalin-fixed paraffin-embedded tissues
    Labeit, D
    Friese, K
    GYNAKOLOGISCH-GEBURTSHILFLICHE RUNDSCHAU, 1995, 35 : 148 - 151
  • [26] Development of an immunohistochemical assay for the detection of babesiosis in formalin-fixed, paraffin-embedded tissue samples
    Torres-Vélez, FJ
    Nace, EK
    Won, KY
    Bartlett, J
    Eberhard, M
    Guarner, J
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 120 (06) : 833 - 838
  • [27] A SIMPLE METHOD FOR ISOLATION OF DNA FROM FORMALIN-FIXED PARAFFIN-EMBEDDED SAMPLES FOR PCR
    KALLIO, P
    SYRJANEN, S
    TERVAHAUTA, A
    SYRJANEN, K
    JOURNAL OF VIROLOGICAL METHODS, 1991, 35 (01) : 39 - 47
  • [28] Oligonucleotide array outperforms SNP array on formalin-fixed paraffin-embedded clinical samples
    Nasri, Soroush
    Anjomshoaa, Ahmad
    Song, Sarah
    Guilford, Parry
    McNoe, Les
    Black, Michael
    Phillips, Vicky
    Reeve, Anthony
    Humar, Bostjan
    CANCER GENETICS AND CYTOGENETICS, 2010, 198 (01) : 1 - 6
  • [29] Semiconductor-Based Sequencing of Formalin-Fixed, Paraffin-Embedded Colorectal Cancer Samples
    Stenzinger, Albrecht
    Pfarr, Nicole
    Penzel, Roland
    Wolf, Thomas
    Schirmacher, Peter
    Endris, Volker
    Weichert, Wilko
    ONCOLOGIST, 2015, 20 (05): : E10 - E11
  • [30] Deamination Effects in Formalin-Fixed, Paraffin-Embedded Tissue Samples in the Era of Precision Medicine
    Kim, Seokhwi
    Park, Charny
    Ji, Yongick
    Kim, Deok G.
    Bae, Hyunsik
    van Vrancken, Michael
    Kim, Duk-Hwan
    Kim, Kyoung-Mee
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2017, 19 (01): : 137 - 146