A Novel Amperometric Glutamate Biosensor Based on Glutamate Oxidase Adsorbed on Silicalite

被引:0
|
作者
O. V. Soldatkina
O. O. Soldatkin
B. Ozansoy Kasap
D. Yu. Kucherenko
I. S. Kucherenko
B. Akata Kurc
S. V. Dzyadevych
机构
[1] Taras Shevchenko National University of Kyiv,Institute of High Technologies
[2] Institute of Molecular Biology and Genetics of NAS of Ukraine,Micro and Nanotechnology Department
[3] Middle East Technical University,Central Laboratory
[4] Middle East Technical University,undefined
来源
关键词
Silicalite; Enzyme; Biosensor; Glutamate oxidase; Amperometry;
D O I
暂无
中图分类号
学科分类号
摘要
In this work, we developed a new amperometric biosensor for glutamate detection using a typical method of glutamate oxidase (GlOx) immobilization via adsorption on silicalite particles. The disc platinum electrode (d = 0.4 mm) was used as the amperometric sensor. The procedure of biosensor preparation was optimized. The main parameters of modifying amperometric transducers with a silicalite layer were determined along with the procedure of GlOx adsorption on this layer. The biosensors based on GlOx adsorbed on silicalite demonstrated high sensitivity to glutamate. The linear range of detection was from 2.5 to 450 μM, and the limit of glutamate detection was 1 μM. It was shown that the proposed biosensors were characterized by good response reproducibility during hours of continuous work and operational stability for several days. The developed biosensors could be applied for determination of glutamate in real samples.
引用
收藏
相关论文
共 50 条
  • [31] Amperometric and impedimetric characterization of a glutamate biosensor based on Nafion® and a methyl viologen modified glassy carbon electrode
    Maalouf, Rita
    Chebib, Hanna
    Saikali, Youssef
    Vittori, Olivier
    Sigaud, Monique
    Jaffrezic-Renault, Nicole
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11): : 2682 - 2688
  • [32] Amperometric biosensor for glutamate using Prussian Blue-based "artificial peroxldase" as a transducer for hydrogen peroxide
    Karyakin, AA
    Karyakina, EE
    Gorton, L
    ANALYTICAL CHEMISTRY, 2000, 72 (07) : 1720 - 1723
  • [33] Capillary biosensor for glutamate
    Cosford, RJO
    Kuhr, WG
    ANALYTICAL CHEMISTRY, 1996, 68 (13) : 2164 - 2169
  • [34] Amperometric biosensor based on glycerol oxidase for glycerol determination
    Goriushkina, T. B.
    Shkotova, L. V.
    Gayda, G. Z.
    Klepach, H. M.
    Gonchar, M. V.
    Soldatkin, A. P.
    Dzyadevych, S. V.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 144 (02) : 361 - 367
  • [35] L-Glutamate biosensor based on L-glutamate oxidase immobilized onto ZnO nanorods/polypyrrole modified pencil graphite electrode
    Batra, Bhawna
    Yadav, Monika
    Pundir, Chandra Shekhar
    BIOCHEMICAL ENGINEERING JOURNAL, 2016, 105 : 428 - 436
  • [36] Development of a novel reagentless, screen-printed amperometric biosensor based on glutamate dehydrogenase and NAD+, integrated with multi-walled carbon nanotubes for the determination of glutamate in food and clinical applications
    Hughes, G.
    Pemberton, R. M.
    Fielden, P. R.
    Hart, J. P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 : 614 - 621
  • [37] A Novel Conductometric Urea Biosensor with Improved Analytical Characteristic Based on Recombinant Urease Adsorbed on Nanoparticle of Silicalite
    Velychko, T. P.
    Soldatkin, O. O.
    Melnyk, V. G.
    Marchenko, S. V.
    Kirdeciler, S. K.
    Akata, B.
    Soldatkin, A. P.
    El'skaya, A. V.
    Dzyadevych, S. V.
    NANOSCALE RESEARCH LETTERS, 2016, 11 : 1 - 6
  • [38] Evaluation of a thermophile enzyme for a carbon paste amperometric biosensor: L-glutamate dehydrogenase
    Jeffries, C
    Pasco, N
    Baronian, K
    Gorton, L
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (03): : 225 - 232
  • [39] A Novel Conductometric Urea Biosensor with Improved Analytical Characteristic Based on Recombinant Urease Adsorbed on Nanoparticle of Silicalite
    T. P. Velychko
    О. О. Soldatkin
    V. G. Melnyk
    S. V. Marchenko
    S. K. Kirdeciler
    B. Akata
    A. P. Soldatkin
    A. V. El’skaya
    S. V. Dzyadevych
    Nanoscale Research Letters, 2016, 11
  • [40] Evaluation of a thermophile enzyme for a carbon paste amperometric biosensor: L-glutamate dehydrogenase
    Jeffries, Cy
    Pasco, Neil
    Baronian, Keith
    Gorton, Lo
    Biosensors and Bioelectronics, 1997, 12 (03): : 225 - 232