Harmonisation of nanoparticle concentration measurements using GRIMM and TSI scanning mobility particle sizers

被引:0
|
作者
Manish Joshi
B. K. Sapra
Arshad Khan
S. N. Tripathi
P. M. Shamjad
Tarun Gupta
Y. S. Mayya
机构
[1] Bhabha Atomic Research Centre,Radiological Physics and Advisory Division
[2] Indian Institute of Technology,Department of Civil Engineering
来源
关键词
Nanoparticles; Harmonisation; SMPS; TSI; GRIMM; Sheath air dryer;
D O I
暂无
中图分类号
学科分类号
摘要
Regional studies focusing on the role of atmospheric nanoparticles in climate change have gained impetus in the last decade. Several multi-institutional studies involving measurement of nanoparticles with several kinds of instruments are on the rise. It is important to harmonize these measurements as the instruments may work on different techniques or principles and are developed by different manufacturers. Scanning mobility particle sizers (SMPS) are often used to measure size distribution of nanoparticles in the airborne phase. Two such commercially available instruments namely, GRIMM and TSI-SMPS have been compared for ambient and laboratory generated conditions. A stand-alone condensation particle counter (CPC) of TSI make was used as a reference for particle concentration measurements. The consistency of the results in terms of mean size and geometric standard deviation was seen to be excellent for both the SMPSs, with GRIMM always showing slightly (approximately 10 %) lower mean size. The integrated number concentration from GRIMM-SMPS was seen to be closer to stand-alone reference CPC compared to TSI-SMPS, for an ambient overnight comparison. However, a concentration-dependent response, i.e. the variations between the two instruments increasing with the concentration, was observed and possible reasons for this have been suggested. A separate experiment was performed for studying the modifying effect of diffusion dryer and sheath air dryer on the measured aerosol size spectra. A significant hygroscopic growth was noted when diffusion dryer was attached to one of the SMPS. The introduction of sheath air dryer in GRIMM-SMPS produced a significant shift towards lower mean size. These results have been compared and discussed with the recent inter-comparison results to strengthen and harmonize the measurement protocols.
引用
收藏
相关论文
共 50 条
  • [21] Investigation of Particle Formation of Electrospray Flame Pyrolysis Using a Scanning Mobility Particle Sizer
    Bierwirth, Malte
    Olszok, Vinzent
    Ganesan, Varun Aiyar
    Poostforooshan, Jalal
    Weber, Alfred P.
    [J]. CHEMIE INGENIEUR TECHNIK, 2021, 93 (08) : 1307 - 1315
  • [22] Nanoparticles in cigarette smoke; real-time undiluted measurements by a scanning mobility particle sizer
    Wouter D. van Dijk
    Simone Gopal
    Paul T. J. Scheepers
    [J]. Analytical and Bioanalytical Chemistry, 2011, 399 : 3573 - 3578
  • [23] Nanoparticles in cigarette smoke; real-time undiluted measurements by a scanning mobility particle sizer
    van Dijk, Wouter D.
    Gopal, Simone
    Scheepers, Paul T. J.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (10) : 3573 - 3578
  • [24] Nanoparticle aggregate volume determination byelectrical mobility analysis: Test of idealized aggregate theory using aerosol particle mass analyzer measurements
    Lall, Anshuman Amit
    Rong, Weizhi
    Madler, Lutz
    Friedlander, Sheldon K.
    [J]. JOURNAL OF AEROSOL SCIENCE, 2008, 39 (05) : 403 - 417
  • [25] Mass-Mobility Measurements Using a Centrifugal Particle Mass Analyzer and Differential Mobility Spectrometer
    Johnson, Tyler J.
    Symonds, Jonathan P. R.
    Olfert, Jason S.
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2013, 47 (11) : 1215 - 1225
  • [26] Absolute Quantification of Bionanoparticles by Electrospray Differential Mobility Analysis: An Application to Lipoprotein Particle Concentration Measurements
    Clouet-Foraison, Noemie
    Gaie-Levrel, Francois
    Coquelin, Loic
    Ebrard, Geraldine
    Gillery, Philippe
    Delatour, Vincent
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (04) : 2242 - 2249
  • [27] On the measurements of magnetic nanoparticle concentration in a biological medium using a superconducting quantum magnetometer
    Bondarenko, S.I.
    Avrunin, O.G.
    Bondarenko, I.S.
    Krevsun, A.V.
    Koverya, V.P.
    Rakhimova, M.V.
    [J]. Fizika Nizkikh Temperatur, 2020, 46 (11): : 1287 - 1291
  • [28] On the measurements of magnetic nanoparticle concentration in a biological medium using a superconducting quantum magnetometer
    Bondarenko, S., I
    Avrunin, O. G.
    Bondarenko, I. S.
    Krevsun, A., V
    Koverya, V. P.
    Rakhimova, M., V
    [J]. LOW TEMPERATURE PHYSICS, 2020, 46 (11) : 1094 - 1097
  • [29] Accurate nanoparticle size determination using electrical mobility measurements in the step and scan modes
    Duelge, Kaleb
    Mulholland, George
    Zachariah, Michael
    Hackley, Vincent A.
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2022, 56 (12) : 1096 - 1113
  • [30] Aerosol particle number concentration measurements in five European cities using TSI-3022 condensation particle counter over a three-year period during health effects pollution on susceptible subpopulations
    Aalto, P
    Hämeri, K
    Paatero, P
    Kulmala, M
    Bellander, T
    Berglind, N
    Bouso, L
    Castano-Vinyals, G
    Sunyer, J
    Cattani, G
    Marconi, A
    Cyrys, J
    von Klot, S
    Peters, A
    Zetzsche, K
    Lanki, T
    Pekkanen, J
    Nyberg, F
    Sjövall, B
    Forastiere, F
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2005, 55 (08) : 1064 - 1076