Kinetic characterization of Prussian Blue-modified graphite electrodes for amperometric detection of hydrogen peroxide

被引:0
|
作者
Raluca C. Cretu
Delia M. Gligor
Laura Muresan
Ionel Catalin Popescu
Liana M. Muresan
机构
[1] Babes-Bolyai University,Department of Physical Chemistry
来源
关键词
amperometric sensors; hydrogen peroxide; modified graphite electrodes; Prussian Blue;
D O I
暂无
中图分类号
学科分类号
摘要
Prussian Blue-modified graphite electrodes (G/PB) with electrocatalytic activity toward H2O2 reduction were obtained by PB potentiostatic electrodeposition from a mixture containing 2.5 mm FeCl3 + 2.5 mm K3[Fe(CN)6] +  0.1 m KCl + 0.1 m HCl. From cyclic voltammetric measurements, performed in KCl aqueous solutions of different concentrations (5 × 10−2–1 m), the rate constant for the heterogeneous electron transfer (ks) was estimated by using the Laviron treatment. The highest ks value (10.7 s−1) was found for 1 m KCl solution. The differences between the electrochemical parameters of the voltammetric response, as well as the shift of the formal potential, observed in the presence of Cl− and NO3− compared to those observed in the presence of SO42− ions, points to the involvement of anions in the redox reactions of PB. The G/PB electrodes showed a good electrochemical stability proved by a low deactivation rate constant (0.8 × 10−12 mol cm2 s−1). The electrocatalytic efficiency, estimated as the ratio \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$(I_{cat})_{H_2 O_2 } /(I_{cat})$$\end{document}, was found to be 3.6 (at an applied potential of 0 mV vs. SCE; Γ = 5 × 10−8 mol cm−2) for a H2O2 concentration of 5 mm, thus indicating G/PB electrodes as possible H2O2 sensors.
引用
收藏
页码:1327 / 1332
页数:5
相关论文
共 50 条
  • [41] Amperometric detection of hydrazine utilizing synergistic action of prussian blue @ silver nanoparticles/graphite felt modified electrode
    Zhao, Jihua
    Liu, Jianxin
    Tricard, Simon
    Wang, Lei
    Liang, Yanling
    Cao, Linghua
    Fang, Jian
    Shen, Weiguo
    ELECTROCHIMICA ACTA, 2015, 171 : 121 - 127
  • [42] Amperometric biosensor based on Prussian Blue-modified screen-printed electrode for lipase activity and triacylglycerol determination
    Rejeb, Ines Ben
    Arduini, Fabiana
    Amine, Aziz
    Gargouri, Mohamed
    Palleschi, Giuseppe
    ANALYTICA CHIMICA ACTA, 2007, 594 (01) : 1 - 8
  • [43] Inkjet Printed Prussian Blue Films for Hydrogen Peroxide Detection
    Hu, Jun-Yu
    Lin, Yu-Ping
    Liao, Ying-Chih
    ANALYTICAL SCIENCES, 2012, 28 (02) : 135 - 140
  • [44] A Prussian blue-based amperometric sensor for the determination of hydrogen peroxide residues in milk
    Jianfeng Ping
    Xiuling Mao
    Kai Fan
    Dongyang Li
    Shiping Ru
    Jian Wu
    Yibin Ying
    Ionics, 2010, 16 : 523 - 527
  • [45] Inkjet Printed Prussian Blue Films for Hydrogen Peroxide Detection
    Jun-Yu Hu
    Yu-Ping Lin
    Ying-Chih Liao
    Analytical Sciences, 2012, 28 : 135 - 140
  • [46] Application of Prussian Blue modified carbon electrodes for amperometric detection of amyloid-β peptides by flow injection analysis
    Suprun, Elena V. V.
    Daboss, Elena V. V.
    Pleshakov, Vladislav M. M.
    Radko, Sergey P. P.
    Karyakin, Arkady A. A.
    Kozin, Sergey A. A.
    Makarov, Alexander A. A.
    Mitkevich, Vladimir A. A.
    Vokhmyanina, Darya V.
    ELECTROCHIMICA ACTA, 2022, 406
  • [47] PRUSSIAN BLUE/REDUCED GRAPHENE OXIDE COMPOSITE FOR THE AMPEROMETRIC DETERMINATION OF DOPAMINE AND HYDROGEN PEROXIDE
    Li, Jinchun
    Jiang, Yuzhou
    Zhai, Yunyun
    Liu, Haiqing
    Li, Lei
    ANALYTICAL LETTERS, 2015, 48 (17) : 2786 - 2798
  • [48] A Prussian blue-based amperometric sensor for the determination of hydrogen peroxide residues in milk
    Ping, Jianfeng
    Mao, Xiuling
    Fan, Kai
    Li, Dongyang
    Ru, Shiping
    Wu, Jian
    Ying, Yibin
    IONICS, 2010, 16 (06) : 523 - 527
  • [49] Green synthesized Au–Ag bimetallic nanoparticles modified electrodes for the amperometric detection of hydrogen peroxide
    Tsung-Hsuan Tsai
    Soundappan Thiagarajan
    Shen-Ming Chen
    Journal of Applied Electrochemistry, 2010, 40 : 2071 - 2076
  • [50] PHOTOELECTROCHEMICAL PROPERTIES OF PRUSSIAN BLUE-MODIFIED GLASSY-CARBON
    UPADHYAY, DN
    GOMATHI, H
    RAO, GP