Kinetic characterization of Prussian Blue-modified graphite electrodes for amperometric detection of hydrogen peroxide

被引:0
|
作者
Raluca C. Cretu
Delia M. Gligor
Laura Muresan
Ionel Catalin Popescu
Liana M. Muresan
机构
[1] Babes-Bolyai University,Department of Physical Chemistry
来源
关键词
amperometric sensors; hydrogen peroxide; modified graphite electrodes; Prussian Blue;
D O I
暂无
中图分类号
学科分类号
摘要
Prussian Blue-modified graphite electrodes (G/PB) with electrocatalytic activity toward H2O2 reduction were obtained by PB potentiostatic electrodeposition from a mixture containing 2.5 mm FeCl3 + 2.5 mm K3[Fe(CN)6] +  0.1 m KCl + 0.1 m HCl. From cyclic voltammetric measurements, performed in KCl aqueous solutions of different concentrations (5 × 10−2–1 m), the rate constant for the heterogeneous electron transfer (ks) was estimated by using the Laviron treatment. The highest ks value (10.7 s−1) was found for 1 m KCl solution. The differences between the electrochemical parameters of the voltammetric response, as well as the shift of the formal potential, observed in the presence of Cl− and NO3− compared to those observed in the presence of SO42− ions, points to the involvement of anions in the redox reactions of PB. The G/PB electrodes showed a good electrochemical stability proved by a low deactivation rate constant (0.8 × 10−12 mol cm2 s−1). The electrocatalytic efficiency, estimated as the ratio \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$(I_{cat})_{H_2 O_2 } /(I_{cat})$$\end{document}, was found to be 3.6 (at an applied potential of 0 mV vs. SCE; Γ = 5 × 10−8 mol cm−2) for a H2O2 concentration of 5 mm, thus indicating G/PB electrodes as possible H2O2 sensors.
引用
收藏
页码:1327 / 1332
页数:5
相关论文
共 50 条
  • [21] PHOTOELECTROCHROMIC BEHAVIOR OF PRUSSIAN BLUE-MODIFIED TIO2 ELECTRODES
    DEBERRY, DW
    VIEHBECK, A
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1983, 130 (01) : 249 - 251
  • [22] Porous anodic alumina electrode modified with a thin film of Prussian blue: Application to amperometric detection of hydrogen peroxide
    Xu, Guorong
    Ren, Fenglian
    Si, Shihui
    Yi, Qingfeng
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2006, 51 (05): : 234 - 243
  • [23] Electrocatalytic reduction of hydrogen peroxide at Prussian blue modified electrodes: a RDE study
    R. Araminaitė
    R. Garjonytė
    A. Malinauskas
    Journal of Solid State Electrochemistry, 2010, 14 : 149 - 155
  • [24] Electrocatalytic reduction of hydrogen peroxide at Prussian blue modified electrodes: a RDE study
    Araminaite, R.
    Garjonyte, R.
    Malinauskas, A.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (01) : 149 - 155
  • [25] Rhodium-Prussian Blue modified carbon paste electrode (Rh-PBMCPE) for amperometric detection of hydrogen peroxide
    Ivama, VM
    Serrano, SHP
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2003, 14 (04) : 551 - 555
  • [26] Prussian blue @ platinum nanoparticles/graphite felt nanocomposite electrodes: Application as hydrogen peroxide sensor
    Han, Lijuan
    Tricard, Simon
    Fang, Jian
    Zhao, Jihua
    Shen, Weiguo
    BIOSENSORS & BIOELECTRONICS, 2013, 43 : 120 - 124
  • [27] Hydrogen peroxide detection using a polypyrrole/Prussian blue nanowire modified electrode
    Lin, Meng
    Yang, Jiao
    Cho, Misuk
    Lee, Youngkwan
    MACROMOLECULAR RESEARCH, 2011, 19 (07) : 673 - 678
  • [28] Hydrogen peroxide detection using a polypyrrole/Prussian blue nanowire modified electrode
    Meng Lin
    Jiao Yang
    Misuk Cho
    Youngkwan Lee
    Macromolecular Research, 2011, 19 : 673 - 678
  • [29] Amperometric biosensor for the detection of hydrogen peroxide using catalase modified electrodes in polyacrylamide
    Varma, S
    Mattiasson, B
    JOURNAL OF BIOTECHNOLOGY, 2005, 119 (02) : 172 - 180
  • [30] Current control by electrode coatings formed by polymerization of dopamine at prussian blue-modified electrodes
    Gao, Bowen
    Su, Lei
    Yang, Hankun
    Shu, Tong
    Zhang, Xueji
    ANALYST, 2016, 141 (06) : 2067 - 2071