Study of Ablation of Arc Contacts and Dynamic Contact Resistance in High Current Breaker

被引:1
|
作者
Licheng Xing
Xiaodong Zhang
Qingbin Tong
Gaoqi Xing
机构
[1] Beijing Jiaotong University,School of Electrical Engineering
[2] State Grid Shandong Power Company,undefined
关键词
Arc ablation; Arcing time; Breaking arc; Contacting resistance; Mass loss;
D O I
暂无
中图分类号
学科分类号
摘要
The fault of power circuit breaker (PCB) can lead very serious problems, especially in high voltage–power grid. The structure of contacts may be composed of main contacts and arc contacts, and this structure can avoid ablation of main contacts efficiently. It is necessary to study the eroded state of the arc contacts and the dynamic contact resistance of arc contacts to estimate the operating state of the PCB. The wear of contacts contains arc ablation and mechanical wear through the characteristics of contacts. The arc ablation is caused by the high temperature of the arc and the mechanical wear is caused by the mechanical friction of static and movable contacts. Some experiments have been done under different size of contacts and different current through them. The results show that the mechanical wear increases, sometimes heavier, with the increase of the size of fixed contacts and the decrease of the size of movable ones because the force between fixed and movable contacts becomes larger. The results also show that the ablation of arc contacts increases with the increase of current, especially when the current is up to 20 kA. With the high temperature of arc reaching the hardness point of copper, the arc ablation and mechanical erosion are increasing obviously since the contacts become soft and easy to wear. Another result of the study shows it is important to choose the material of contacts and the force between movable and fixed contacts. The harder and less resistance the material of contacts, the better the operating situation. To monitor the operating situation of the breaker, the dynamic contact resistance was measured 25 times. As a result, the dynamic contact resistance is sensitive to the current and increasing with the increase of continuous experiment time because of the increasing of metal ions. Furthermore, if the SF6 in the PCB is changes, the dynamic contact resistance would be changed. The dynamic contact resistance in this experiment varies substantially within the range of 80–250 μΩ at the current of 20 kA.
引用
收藏
页码:1015 / 1023
页数:8
相关论文
共 50 条
  • [1] Study of Ablation of Arc Contacts and Dynamic Contact Resistance in High Current Breaker
    Xing, Licheng
    Zhang, Xiaodong
    Tong, Qingbin
    Xing, Gaoqi
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (03) : 1015 - 1023
  • [2] Application of dynamic resistance measurement in the contact ablation assessment of high voltage SF6 circuit breaker
    Yang, Jing-Gang
    Liu, Ya-Kui
    Gao, Shan
    Zhao, Ke
    Li, Hong-Tao
    Zhang, Guo-Gang
    [J]. PROCEEDINGS OF THE 2ND ANNUAL INTERNATIONAL CONFERENCE ON ELECTRONICS, ELECTRICAL ENGINEERING AND INFORMATION SCIENCE (EEEIS 2016), 2016, 117 : 135 - 140
  • [3] Erosion characteristics of SF6 circuit breaker contacts based on dynamic contact resistance measurement
    Lan L.
    Chen G.
    Wen X.
    Wu Y.
    [J]. Chen, Gong (gongchen714@163.com), 1731, Science Press (42): : 1731 - 1738
  • [4] Study of an ablation-dominated arc in a model circuit breaker
    Eichhoff, D.
    Kurz, A.
    Kozakov, R.
    Goett, G.
    Uhrlandt, D.
    Schnettler, A.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2012, 45 (30)
  • [5] Experimental study on arc ablation occurring in a contact strip rubbing against a contact wire with electrical current
    Chen, G. X.
    Yang, H. J.
    Zhang, W. H.
    Wang, X.
    Zhang, S. D.
    Zhou, Z. R.
    [J]. TRIBOLOGY INTERNATIONAL, 2013, 61 : 88 - 94
  • [6] Analysis of contact ablation of circuit breaker after short circuit current breaking
    Mao, Xiaopo
    Ye, Jianfeng
    Xiong, Yu
    Tian, Ze
    Hu, Kuan
    Wang, Jiaqiang
    Feng, Hongwu
    [J]. AIP ADVANCES, 2023, 13 (10)
  • [7] Influence of Arc Discharge on Contact Resistance of AgNi Contacts for Electromagnetic Contactors
    Yoshida, Kiyoshi
    Sawa, Koichiro
    Suzuki, Kenji
    Watanabe, Masaaki
    [J]. IEICE TRANSACTIONS ON ELECTRONICS, 2012, E95C (09) : 1531 - 1534
  • [8] Arc and contact resistance characteristics of Ag and Pd contacts in dielectric liquids
    Hayakawa, T
    Sawa, K
    [J]. IEICE TRANSACTIONS ON ELECTRONICS, 1998, E81C (03) : 392 - 398
  • [9] Arc Contact Ablation: High Speed Camera Visualization
    Masquere, Mathieu
    Hernandez, Karina
    Freton, Pierre
    Gonzalez, Jean-Jacques
    Razafinimanana, Manitra
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2014, 42 (10) : 2380 - 2381
  • [10] Dynamic Resistance Measurement Based on the Whole Lifetime of Breaker Arcing Contact
    Chen, Gong
    Ma, Lingteng
    Zhu, Zheng
    Lu, Xiaojun
    Li, Mengbo
    Zeng, Weiwen
    [J]. 2021 POWER SYSTEM AND GREEN ENERGY CONFERENCE (PSGEC), 2021, : 687 - 692