Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigation

被引:5
|
作者
Ahmad Faizan
Vijay K. Goel
Steven R. Garfin
Christopher M. Bono
Hassan Serhan
Ashok Biyani
Hossein Elgafy
Manoj Krishna
Tai Friesem
机构
[1] University of Toledo,Engineering Center for Orthopaedic Research Excellence (E
[2] University of California,CORE), Departments of Bioengineering and Orthopaedic Surgery, 5046 NI, MS 303, Colleges of Engineering and Medicine
[3] San Diego,Department of Orthopaedics
[4] Harvard Medical School,Brigham and Women’s Hospital
[5] DePuy Spine,undefined
[6] The University Hospital of North Tees,undefined
来源
European Spine Journal | 2012年 / 21卷
关键词
Cervical; Disc replacement; Finite element; Biomechanics; Design variation;
D O I
暂无
中图分类号
学科分类号
摘要
Various ball and socket-type designs of cervical artificial discs are in use or under investigation. Many artificial disc designs claim to restore the normal kinematics of the cervical spine. What differentiates one type of design from another design is currently not well understood. In this study, authors examined various clinically relevant parameters using a finite element model of C3–C7 cervical spine to study the effects of variations of ball and socket disc designs. Four variations of ball and socket-type artificial disc were placed at the C5–C6 level in an experimentally validated finite element model. Biomechanical effects of the shape (oval vs. spherical ball) and location (inferior vs. superior ball) were studied in detail. Range of motion, facet loading, implant stresses and capsule ligament strains were computed to investigate the influence of disc designs on resulting biomechanics. Motions at the implant level tended to increase following disc replacement. No major kinematic differences were observed among the disc designs tested. However, implant stresses were substantially higher in the spherical designs when compared to the oval designs. For both spherical and oval designs, the facet loads were lower for the designs with an inferior ball component. The capsule ligament strains were lower for the oval design with an inferior ball component. Overall, the oval design with an inferior ball component, produced motion, facet loads, implant stresses and capsule ligament strains closest to the intact spine, which may be key to long-term implant survival.
引用
收藏
页码:653 / 662
页数:9
相关论文
共 50 条
  • [21] Influence of assigned material combination in a simulated total cervical disc replacement design on kinematics of a model of the full cervical spine: A finite element analysis study
    Qi, Yuxin
    Lewis, Gladius
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2016, 27 (06) : 633 - 646
  • [22] Cervical spine morphology and ligament property variations: A finite element study of their influence on sagittal bending characteristics
    John, Jobin D.
    Kumar, Gurunathan Saravana
    Yoganandan, Narayan
    JOURNAL OF BIOMECHANICS, 2019, 85 : 18 - 26
  • [23] Biomechanical Analysis of the Cervical Spine Following Disc Degeneration, Disc Fusion, and Disc Replacement: A Finite Element Study
    Gandhi, Anup A.
    Grosland, Nicole M.
    Kallemeyn, Nicole A.
    Kode, Swathi
    Fredericks, Douglas C.
    Smucker, Joseph D.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2019, 13 (06): : 491 - 500
  • [24] Parameters that effect spine biomechanics following cervical disc replacement
    Goel, Vijay K.
    Faizan, Ahmad
    Palepu, Vivek
    Bhattacharya, Sanghita
    EUROPEAN SPINE JOURNAL, 2012, 21 : S688 - S699
  • [25] Parameters that effect spine biomechanics following cervical disc replacement
    Vijay K. Goel
    Ahmad Faizan
    Vivek Palepu
    Sanghita Bhattacharya
    European Spine Journal, 2012, 21 : 688 - 699
  • [26] Investigation of the influence of interbody fusion on biomechanics of the cervical spine using a computer model
    Lehner, Stefan
    Schreiber, Ulrich
    ADVANCES IN MEDICAL ENGINEERING, 2007, 114 : 279 - +
  • [27] Locations of initial failure in the lower cervical spine: a finite element investigation
    Mabe, Isaac
    Weiss, Chelsea
    Goswami, Tarun
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (02):
  • [28] FINITE ELEMENT ANALYSIS OF CERVICAL SPINE WITH DIFFERENT CONSTRAINED TYPES OF TOTAL DISC REPLACEMENT
    Lin, Chien-Yu
    Chuang, Shih-Youeng
    Chiang, Chang-Jung
    Tsuang, Yang-Hwei
    Chen, Weng-Pin
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2014, 14 (03)
  • [29] Finite element analysis of a new intervertebral disc prosthesis developed for the canine cervical spine
    Tertuliano Marinho, Paulo Vinicius
    Macedo, Ana Paula
    de Sampaio, Claudio Pereira
    Shimano, Antonio Carlos
    Zani Marinho, Carolina Camargo
    Bahr Arias, Monica Vicky
    CIENCIA RURAL, 2023, 53 (06):
  • [30] Use of prestige® LP artificial cervical disc in the spine
    Traynelis, Vincent C.
    Treharne, Richard W.
    EXPERT REVIEW OF MEDICAL DEVICES, 2007, 4 (04) : 437 - 440