Intelligent telemetric stent for wireless monitoring of intravascular pressure and its in vivo testing

被引:0
|
作者
Xing Chen
Daniel Brox
Babak Assadsangabi
York Hsiang
Kenichi Takahata
机构
[1] University of British Columbia,Department of Electrical and Computer Engineering
[2] University of British Columbia,Department of Surgery, Vancouver General Hospital
来源
Biomedical Microdevices | 2014年 / 16卷
关键词
Stents; Restenosis; Wireless sensing; Radio-frequency antennas; Pressure sensors; Micro-electro-mechanical systems; Stainless steels;
D O I
暂无
中图分类号
学科分类号
摘要
This paper reports a sensor-integrated telemetric stent targeted at wireless detection and monitoring of restenosis, a common vascular complication induced by stent implantation. The developed “smart” stent incorporates the design and fabrication approaches that raise the practicality of the device, being tested in an in vivo study that validates its operating principle. The stent is produced to have a gold-coated helical-like structure that serves as a high-performance inductor/antenna and integrated with a novel capacitive pressure sensor chip, all based on medical-grade stainless steel. The stent device forms an inductor-capacitor resonant tank that enables radio-frequency (RF) wireless pressure sensing in an operating frequency range of 30–80 MHz. With an overall length of 20 mm, the device is designed to be compatible with standard balloon catheters and necessary crimping process. The balloon-expanded devices are characterized in saline and blood to determine selective coating of passivation layer, Parylene C, with tailored thicknesses in order to maximize both RF and sensing abilities. In vitro testing of the devices reveals a frequency sensitivity up to 146 ppm/mmHg over a pressure range of 250 mmHg. Tests in pig models show wireless detection of device’s resonance and frequency response to variations in local blood pressure, the targeted function of the device.
引用
收藏
页码:745 / 759
页数:14
相关论文
共 46 条
  • [21] Long-term Intravascular Blood-Pressure Monitoring with a Novel, Wireless Sensor System - Results from Chronic In-vivo Studies
    Cleven, Nina
    Woitok, Anna
    Isfort, Peter
    Penzkofer, Tobias
    Goertz, Michael
    Goettsche, Thorsten
    Steinseifer, Ulrich
    Schmitz-Rode, Thomas
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B33 - B33
  • [22] MEMS-ENABLED WIRELESS URETERAL STENT WITH INTEGRATED ANTENNA FOR LOCAL PRESSURE MONITORING
    Darestani, Mohammad Reza Yousefi
    Shalabi, Nabil
    Lange, Dirk
    Chew, Ben H.
    Takahata, Kenichi
    [J]. 2021 21ST INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2021, : 345 - 348
  • [23] Wireless Bioelectronics for In Vivo Pressure Monitoring with Mechanically-Compliant Hydrogel Biointerfaces
    Lin, Jingsen
    Chen, Xingmei
    Zhang, Pei
    Xue, Yu
    Feng, Yinghui
    Ni, Zhipeng
    Tao, Yue
    Wang, Yafei
    Liu, Ji
    [J]. ADVANCED MATERIALS, 2024, 36 (26)
  • [24] Continuous monitoring of cardiovascular function with a smart stent incorporating a flexible and stretchable wireless pressure sensor
    Oyunbaatar, Nomin-Erdene
    Shanmugasundaram, Arunkumar
    Kwon, Kyeongha
    Lee, Dong-Weon
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2023, 33 (11)
  • [25] Monitoring In Vivo Absorption of a Drug-Eluting Bioabsorbable Stent With Intravascular Ultrasound-Derived Parameters A Feasibility Study
    Bruining, Nico
    de Winter, Sebastiaan
    Roelandt, Jos R. T. C.
    Regar, Evelyn
    Heller, Iddo
    van Domburg, Ron T.
    Hamers, Ronald
    Onuma, Yoshinobu
    Dudek, Darius
    Webster, Mark W. I.
    Thuesen, Leif
    Ormiston, John A.
    Cheong, Wai-Fung
    Miguel-Hebert, Karine
    Veldhof, Susan
    Serruys, Patrick W.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (04) : 449 - 456
  • [26] Graphene-Based Wireless Tube-Shaped Pressure Sensor for In Vivo Blood Pressure Monitoring
    Inoue, Nagisa
    Koya, Yoshihiko
    Miki, Norihisa
    Onoe, Hiroaki
    [J]. MICROMACHINES, 2019, 10 (02)
  • [27] A Wireless Power-Free Pressure Sensor for Real-Time In Vivo Gastrointestinal Pressure Monitoring
    Shi, Qiang
    Chen, Deyong
    Wang, Junbo
    Bao, Kaikai
    Liu, Lijuan
    [J]. MICRO-NANO TECHNOLOGY XV, 2014, 609-610 : 993 - 996
  • [28] Self-rollable Polymer Stent Integrated with Wireless Pressure Sensor for Real-time Monitoring of Cardiovascular Pressure
    Oyunbaatar, Nomin-Erdene
    Kim, Dong-Su
    Prasad, Gajula
    Jeong, Yun-Jin
    Lee, Dong-Weon
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2022, 346
  • [29] Design of a wireless telemetric backpack device for real-time in vivo measurement of pressure-volume loops in conscious ambulatory rats
    Raghavan, Karthik
    Kottam, Anil T. G.
    Valvano, Jonathan W.
    Pearce, John A.
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 993 - +
  • [30] In Vitro and In Vivo characterization of wireless and passive micro system enabling gastrointestinal pressure monitoring
    Qiang Shi
    Junbo Wang
    Deyong Chen
    Jian Chen
    Jing Li
    Kaikai Bao
    [J]. Biomedical Microdevices, 2014, 16 : 859 - 868