Tip-Apex Distance as a Predictor of Failure Following Cephalo-Medullary Fixation for Unstable Fractures of the Proximal Femur

被引:0
|
作者
Michael J. Walton
Andrew J. Barnett
Mark Jackson
机构
[1] Bristol Royal Infirmary,
[2] Trauma and Orthopedics,undefined
[3] Bristol Royal Infirmary,undefined
关键词
Fractures of the proximal femur; Hip fracture; Intramedullary nailing of long bones;
D O I
暂无
中图分类号
学科分类号
摘要
Current research has been unable to confirm that intramedullary fixation provides greater stability for unstable fracture configurations of the proximal femur than extra-medullary devices. We present a retrospective analysis of the outcome of proximal femoral fractures treated with the Proximal Femoral Nail (PFN, Synthes) with particular reference to implant position and adequacy of reduction. Between May 2002 and October 2004, 61 patients with low-energy unstable proximal femoral fractures underwent surgery at a mean 2.4 days. Mean age was 78 years, 74% were female. Four (6.9%) implants failed secondary to proximal cut out of the hip screw. All of the failures occurred in patients who had sustained AO/OTA type 31. A3 fractures. In patients with A3 fracture patterns, there is a significant relationship between increasing Tip-Apex distance (p = 0.023), varus mal-reduction (p = 0.038) and failure; 46% patients died within 12 months of surgery. The PFN is a satisfactory implant in the management of unstable proximal femoral fractures, however accurate reduction and implant position are essential to provide the best conditions for union and to prevent implant failure.
引用
下载
收藏
页码:273 / 276
页数:3
相关论文
共 28 条
  • [21] Tip-neck distance ratio as a novel predictor for failure in cephalomedullary nailing of unstable trochanteric fractures (UTF)
    Cepni, Sahin
    Subasi, Izzet Ozay
    Sahin, Ali
    Bozkurt, Ibrahim
    Firat, Ahmet
    Kilicarslan, Kasim
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (10) : 2619 - 2626
  • [22] Tip-to-apex distance does not predict fixation failure regardless of reduction quality in intra-capsular neck of femur fractures treated with femoral neck system
    Leung, Hiu Yan
    Wong, Janus Siu Him
    Fang, Christian
    Tsoi, Calvin
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2024, 31 (01) : 55 - 59
  • [23] Standardized Tip-Apex Distance (STAD): a modified individualized measurement of cephalic fixator position based on its own femoral head diameter in geriatric intertrochanteric fractures with internal fixation
    Yang, Yun-fa
    Huang, Jian-wen
    Gao, Xiao-sheng
    Xu, Zhong-he
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [24] Trochanteric fractures treated by internal fixation using short intramedullary nails: Does the visual intraoperative estimation of the Tip-Apex Distance (TAD) concur with its digital postoperative measurement?
    Drouinaud, Adrien
    Alain, Armand
    Caudron, Sebastien
    Cunique, Thibaut
    Auditeau, Emilie
    Marcheix, Pierre-Sylvain
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (06)
  • [25] Standardized Tip-Apex Distance (STAD): a modified individualized measurement of cephalic fixator position based on its own femoral head diameter in geriatric intertrochanteric fractures with internal fixation
    Yun-fa Yang
    Jian-wen Huang
    Xiao-sheng Gao
    Zhong-he Xu
    BMC Musculoskeletal Disorders, 24
  • [26] Fixation failure of the LCP proximal femoral plate 4.5/5.0 in patients with missing posteromedial support in unstable per-, inter-, and subtrochanteric fractures of the proximal femur
    Wieser, Karl
    Babst, Reto
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (10) : 1281 - 1287
  • [27] Fixation failure of the LCP proximal femoral plate 4.5/5.0 in patients with missing posteromedial support in unstable per-, inter-, and subtrochanteric fractures of the proximal femur
    Karl Wieser
    Reto Babst
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 1281 - 1287
  • [28] Greater rate of cephalic screw mobilisation following proximal femoral nailing in hip fractures with a tip–apex distance (TAD) and a calcar referenced TAD greater than 25 mm
    Rocco Aicale
    Nicola Maffulli
    Journal of Orthopaedic Surgery and Research, 13