Standardized Tip-Apex Distance (STAD): a modified individualized measurement of cephalic fixator position based on its own femoral head diameter in geriatric intertrochanteric fractures with internal fixation

被引:1
|
作者
Yang, Yun-fa [1 ]
Huang, Jian-wen [1 ]
Gao, Xiao-sheng [1 ]
Xu, Zhong-he [1 ]
机构
[1] South China Univ Technol, Affiliated Hosp 2, Guangzhou Peoples Hosp 1, Sch Med,Dept Orthopaed Surg, 1 Panfu Rd, Guangzhou 510180, Guangdong, Peoples R China
关键词
Standardized tip-apex Distance; Intertrochanteric fracture; Internal fixation; Cut-out; The elderly; SLIDING HIP SCREW; RETROSPECTIVE ANALYSIS; CUTOUT; PREDICTORS; FAILURE; FEMUR; INTRAMEDULLARY; COMPLICATIONS; ANTIROTATION;
D O I
10.1186/s12891-023-06286-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveTo design a standardized Tip-Apex Distance (STAD) and analyze the clinical significance of STAD in predicting cut-out in geriatric intertrochanteric fractures with internal fixation.MethodsFirstly, we designed STAD according to the rule of TAD. We measured the STAD individually based on its own femoral head diameter (iFHD) instead of the known diameter of the lag screw in calculating TAD, resulting in that the STAD is simply the relative quantitation relationship of iFHD (the times of iFHD). In this study, we assumed that all the iFHD was 6D (1iFHD = 6D, or 1D = 1/6 of iFHD) in order for complete match of the Cleveland zone system, easy comparison of the STAD, and convenient identification for artificial intelligence. Secondly, we calculated and recorded all the STAD of cephalic fixator in 123 eligible ITF patients. Thirdly, we grouped all the ITF patients into the Failure and Non-failure groups according to whether cut-out or not, and analyzed the correlation between the cut-out and the STAD.ResultsCleveland zone, Parker's ratio (AP), TAD, and STAD were associated with the cut-out in univariate analysis. However, only STAD was the independent predictor of the cut-out by multivariate analysis. No cut-out was observed when STAD <= 2D (1/3 of iFHD). The Receiver Operating Characteristic (ROC) curve indicated that STAD was a reliable predictor of cut-out, and the best cut-off value of STAD was 2.92D. Cut-out rate increased dramatically when STAD increased, especially when STAD > 3D (1/2 of iFHD).ConclusionEssentially, the STAD is a relative quantitation relationship of iFHD. The STAD is a reliable measurement of cephalic fixator position in predicting cut-out in geriatric ITF patients with single-screw cephalomedullary nail fixations. For avoiding cut-out, the STAD should be no more than a half of iFHD.
引用
收藏
页数:10
相关论文
共 6 条
  • [1] Standardized Tip-Apex Distance (STAD): a modified individualized measurement of cephalic fixator position based on its own femoral head diameter in geriatric intertrochanteric fractures with internal fixation
    Yun-fa Yang
    Jian-wen Huang
    Xiao-sheng Gao
    Zhong-he Xu
    BMC Musculoskeletal Disorders, 24
  • [2] The correlation between cutout and eccentric distance (ED) of the cephalic fixator tip in geriatric intertrochanteric fractures with internal fixation
    Yun-fa Yang
    Jian-wen Huang
    Xiao-sheng Gao
    Zhong-he Xu
    Journal of Orthopaedic Surgery and Research, 17
  • [3] The correlation between cutout and eccentric distance (ED) of the cephalic fixator tip in geriatric intertrochanteric fractures with internal fixation
    Yang, Yun-fa
    Huang, Jian-wen
    Gao, Xiao-sheng
    Xu, Zhong-he
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [4] Impact of tip-apex distance and femoral head lag screw position on treatment outcomes of unstable intertrochanteric fractures using cephalomedullary nails
    Lee, Cheng-Hung
    Su, Kuo-Chih
    Chen, Kun-Hui
    Pan, Chien-Chou
    Wu, Yun-Che
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (06) : 2128 - 2140
  • [5] Eccentric distance zone analysis system: New regional evaluation of cephalic fixator tip location for predicting cut-out in geriatric intertrochanteric fractures with internal fixation
    Yang, Yun-fa
    Huang, Jian-wen
    Gao, Xiao-sheng
    Xu, Zhong-he
    FRONTIERS IN SURGERY, 2022, 9
  • [6] Trochanteric fractures treated by internal fixation using short intramedullary nails: Does the visual intraoperative estimation of the Tip-Apex Distance (TAD) concur with its digital postoperative measurement?
    Drouinaud, Adrien
    Alain, Armand
    Caudron, Sebastien
    Cunique, Thibaut
    Auditeau, Emilie
    Marcheix, Pierre-Sylvain
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (06)