A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography

被引:0
|
作者
Michael T. Hirschmann
Farhad Iranpour
Praveen Konala
Anna Kerner
Helmut Rasch
Justin P. Cobb
Niklaus F. Friederich
机构
[1] Kantonsspital Bruderholz,Department of Orthopaedic Surgery and Traumatology
[2] Imperial College,Department of Musculoskeletal Surgery
[3] Kantonsspital Bruderholz,Institute for Radiology and Nuclear Medicine
关键词
Knee; SPECT/CT; Replacement; Painful total knee arthroplasty; Localization scheme;
D O I
暂无
中图分类号
学科分类号
摘要
SPECT/CT is a promising diagnostic modality in patients with painful total knee arthroplasty (TKA). The purpose of this study is to introduce a novel standardized SPECT/CT algorithm and evaluate its clinical application and reliability. A novel SPECT/CT localization scheme consisting of 9 tibial, 9 femoral and 4 patellar regions on standardized axial, coronal and sagittal slices is proposed. It was piloted in 18 consecutive patients with post TKA pain. The tracer activity on SPECT/CT was recorded using a color-coded scale (0–10). The inter- and intra-observer reliability was assessed for localization and tracer activity. The prosthetic component position was assessed in the CT images after 3D reconstruction using standardized frames of reference. The median inter- and intra-observer differences and ranges of the measured angles were calculated along with the ICC values for inter- and intra-observer reliability. The localization scheme showed very high inter- and intra-observer reliabilities for all regions. The measurement of component position was highly reliable in all cases with sufficient visibility of anatomical landmarks. The median inter-observer difference between alignment measurements for tibial and femoral components was less than 3° (range 0°–6°). The median intra-observer variability for these was less than 2° (range 0°–5°). The SPECT/CT algorithm presented is both reliable and useful in the management of patients with painful TKA. It combines biomechanical and metabolic data (tracer localization) providing an extra dimension to the understanding of this difficult condition. The clinical value of SPECT/CT in patients with unexplained pain following TKA should be further investigated.
引用
收藏
页码:939 / 944
页数:5
相关论文
共 50 条
  • [41] PERIPROSTHETIC BONE TURNOVER AFTER PRIMARY TOTAL HIP ARTHROPLASTY MEASURED BY SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY
    Venesmaa, P.
    Vanninen, E.
    Miettinen, H.
    Kroger, H.
    SCANDINAVIAN JOURNAL OF SURGERY, 2012, 101 (04) : 241 - 248
  • [42] OPIATE DEPENDENCE AND WITHDRAWAL - PRELIMINARY ASSESSMENT USING SINGLE-PHOTON EMISSION COMPUTERIZED-TOMOGRAPHY (SPECT)
    KRYSTAL, JH
    WOODS, SW
    KOSTEN, TR
    ROSEN, MI
    SEIBYL, JP
    VANDYCK, CC
    PRICE, LH
    ZUBAL, IG
    HOFFER, PB
    CHARNEY, DS
    AMERICAN JOURNAL OF DRUG AND ALCOHOL ABUSE, 1995, 21 (01): : 47 - 63
  • [43] Bone mineral density and single photon emission computed tomography changes after total knee arthroplasty:: a 2-year follow-up study
    Soininvaara, Tarja
    Nikola, Tua
    Vanninen, Esko
    Miettinen, Hannu
    Kroger, Heikki
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2008, 28 (02) : 101 - 106
  • [44] A novel standardized algorithm using SPECT/CT evaluating unhappy patients after unicondylar knee arthroplasty- a combined analysis of tracer uptake distribution and component position
    Suter, Basil
    Testa, Enrique
    Stämpfli, Patrick
    Konala, Praveen
    Rasch, Helmut
    Friederich, Niklaus F.
    Hirschmann, Michael T.
    BMC MEDICAL IMAGING, 2015, 15 : 1
  • [45] Quantitative liver-spleen scan using single photon emission computerized tomography (SPECT) for assessment of hepatic function in cirrhotic patients
    Zuckerman, E
    Slobodin, G
    Sabo, E
    Yeshurun, D
    Naschitz, JE
    Groshar, D
    JOURNAL OF HEPATOLOGY, 2003, 39 (03) : 326 - 332
  • [46] Correlation of Uptake Patterns on Single-Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) and Treatment Response in Patients with Knee Pain
    Koh G.
    Hwang K.H.
    Lee H.
    Kim S.G.
    Lee B.K.
    Nuclear Medicine and Molecular Imaging, 2016, 50 (2) : 137 - 143
  • [47] SINGLE PHOTON-EMISSION COMPUTERIZED-TOMOGRAPHY (SPECT) - A NOVEL TECHNIQUE FOR IMAGING INFLAMMATORY BOWEL-DISEASE USING TC HMPAO
    WELDON, MJ
    MASOOMI, AM
    JOSEPH, AEA
    MAXWELL, JD
    GUT, 1992, 33 (02) : S3 - S3
  • [48] Quantitative Bone Single Photon Emission Computed Tomography/Computed Tomography for Evaluating Response to Bisphosphonate Treatment in Patients with Paget's Disease of Bone
    Kitajima, Kazuhiro
    Futani, Hiroyuki
    Tsuchitani, Tatsuya
    Takahashi, Yoshiyuki
    Yamakado, Koichiro
    CASE REPORTS IN ONCOLOGY, 2020, 13 (02): : 829 - 834
  • [49] Estimating center of rotation of single-photon emission computerized tomography projection images using MATLAB for standardization and calibration
    Pandey, Anil Kumar
    Chaudhary, Jagrati
    Kaur, Gagandeep
    Yadav, Priya
    Sharma, Param Dev
    Patel, Chetan
    Kumar, Rakesh
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2023, 38 (01): : 23 - 33
  • [50] Validation of topographic hybrid single-photon emission computerized tomography with computerized tomography scan in patients with and without nonspecific chronic low back pain. A prospective comparative study
    Van de Kelft, Erik
    Verleye, Gino
    Van de Kelft, An-Sofie
    Melis, Koen
    Van Goethem, Johan
    SPINE JOURNAL, 2017, 17 (10): : 1457 - 1463