A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography

被引:0
|
作者
Michael T. Hirschmann
Farhad Iranpour
Praveen Konala
Anna Kerner
Helmut Rasch
Justin P. Cobb
Niklaus F. Friederich
机构
[1] Kantonsspital Bruderholz,Department of Orthopaedic Surgery and Traumatology
[2] Imperial College,Department of Musculoskeletal Surgery
[3] Kantonsspital Bruderholz,Institute for Radiology and Nuclear Medicine
关键词
Knee; SPECT/CT; Replacement; Painful total knee arthroplasty; Localization scheme;
D O I
暂无
中图分类号
学科分类号
摘要
SPECT/CT is a promising diagnostic modality in patients with painful total knee arthroplasty (TKA). The purpose of this study is to introduce a novel standardized SPECT/CT algorithm and evaluate its clinical application and reliability. A novel SPECT/CT localization scheme consisting of 9 tibial, 9 femoral and 4 patellar regions on standardized axial, coronal and sagittal slices is proposed. It was piloted in 18 consecutive patients with post TKA pain. The tracer activity on SPECT/CT was recorded using a color-coded scale (0–10). The inter- and intra-observer reliability was assessed for localization and tracer activity. The prosthetic component position was assessed in the CT images after 3D reconstruction using standardized frames of reference. The median inter- and intra-observer differences and ranges of the measured angles were calculated along with the ICC values for inter- and intra-observer reliability. The localization scheme showed very high inter- and intra-observer reliabilities for all regions. The measurement of component position was highly reliable in all cases with sufficient visibility of anatomical landmarks. The median inter-observer difference between alignment measurements for tibial and femoral components was less than 3° (range 0°–6°). The median intra-observer variability for these was less than 2° (range 0°–5°). The SPECT/CT algorithm presented is both reliable and useful in the management of patients with painful TKA. It combines biomechanical and metabolic data (tracer localization) providing an extra dimension to the understanding of this difficult condition. The clinical value of SPECT/CT in patients with unexplained pain following TKA should be further investigated.
引用
收藏
页码:939 / 944
页数:5
相关论文
共 50 条
  • [31] Imaging of the dopaminergic neurotransmission system using single-photon emission tomography and positron emission tomography in patients with parkinsonism
    Jan Booij
    Gerrit Tissingh
    Ania Winogrodzka
    Eric A. van Royen
    European Journal of Nuclear Medicine, 1999, 26 : 171 - 182
  • [32] A novel standardized algorithm using SPECT/CT evaluating patients after unicondylar knee arthroplasty-a combined analysis of tracer uptake distribution and com
    Testa, Enrique Adrian
    Suter, Basil
    Friederich, Niklaus
    Stampfli, Patrick
    Konala, Praveen
    Rasch, Helmut
    Hirschmann, Michael Tobias
    SWISS MEDICAL WEEKLY, 2014, 144 : 48S - 48S
  • [33] Correlation of Single-Photon Emission Computed Tomography Results With Clinical and Intraoperative Findings in Painful Total Ankle Replacement
    Gurbani, Ajay
    Demetracopoulos, Constantine
    O'Malley, Martin
    Deland, Jonathan
    Cody, Elizabeth
    Sofka, Carolyn
    Scharf, Stephen
    Ellis, Scott
    FOOT & ANKLE INTERNATIONAL, 2020, 41 (06) : 639 - 646
  • [34] A STUDY OF DEPRESSION IN OLD-AGE USING SINGLE-PHOTON EMISSION COMPUTERIZED-TOMOGRAPHY
    UPADHYAYA, AK
    ABOUSALEH, MT
    WILSON, K
    GRIME, SJ
    CRITCHLEY, M
    BRITISH JOURNAL OF PSYCHIATRY, 1990, 157 : 76 - 81
  • [35] Determination of kidney volume using single-photon emission computerized tomography and Tc-99m-DMSA: Comparison with transmission computerized tomography (TCT).
    Groshar, D
    Odeh, M
    Moskovitz, B
    Issaq, E
    Nativ, O
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 16P - 16P
  • [36] A novel standardized algorithm using SPECT/CT evaluating unhappy patients after unicondylar knee arthroplasty– a combined analysis of tracer uptake distribution and component position
    Basil Suter
    Enrique Testa
    Patrick Stämpfli
    Praveen Konala
    Helmut Rasch
    Niklaus F Friederich
    Michael T Hirschmann
    BMC Medical Imaging, 15
  • [37] Single photon emission tomography combined with computer tomography (SPECT/CT) for assessment of COPD patients for lung volume reduction surgery
    Lardinois, D.
    Rasch, H.
    Kneifel, S.
    Gambazzi, F.
    Tamm, M.
    Stolz, D.
    SWISS MEDICAL WEEKLY, 2008, 138 : 31S - 31S
  • [38] Magnetic resonance imaging (MRI) versus single photon emission computed tomography (SPECT/CT) in painful total hip arthroplasty: a comparative multi-institutional analysis
    Baecker, Henrik C.
    Steurer-Dober, Isabelle
    Beck, Martin
    Agten, Christoph A.
    Decking, Jens
    Herzog, Richard F.
    Geller, Jeffrey A.
    Bhure, Ujwal
    Roos, Justus E.
    Strobel, Klaus
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1105):
  • [39] EVALUATION OF THE EFFECTS OF TOTAL SLEEP-DEPRIVATION ON CEREBRAL BLOOD-FLOW USING SINGLE PHOTON-EMISSION COMPUTERIZED-TOMOGRAPHY
    VOLK, S
    KAENDLER, SH
    WEBER, R
    GEORGI, K
    MAUL, F
    HERTEL, A
    PFLUG, B
    HOR, G
    ACTA PSYCHIATRICA SCANDINAVICA, 1992, 86 (06) : 478 - 483
  • [40] Diagnostic criteria for temporomandibular joint osteoarthritis using standardized uptake value in single-photon emission computed tomography-computed tomography
    Kim, Jae-Young
    Lee, Chaeyeon
    Park, Young Long
    Lee, Jae-Hoon
    Ryu, Young Hoon
    Huh, Jong-Ki
    SCIENTIFIC REPORTS, 2024, 14 (01):