Experimental Validation of a Numerical Model of an Axial Circulatory Assist Blood Pump

被引:0
|
作者
A. M. Gouskov
F. D. Sorokin
E. P. Banin
A. E. Krupnin
S. V. Skoryukov
机构
[1] Bauman Moscow State Technical University,
[2] Mechanical Engineering Research Institute of the Russian Academy of Sciences,undefined
[3] National Research Center “Kurchatov Institute”,undefined
来源
Biomedical Engineering | 2019年 / 53卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This study continues our systematic exploration of the design of an axial circulatory assist blood pump with a rotor on magnetic bearings. The work reported here addresses experimental validation of a numerical model of flow in the flow part of the axial blood pump. The study focuses on design of the test rig, design of experiments, and modeling of blood flow in the flow part of the pump using computational fluid dynamics. The working fluid was distilled water. The flow-pressure characteristics obtained experimentally were compared with those from mathematical modeling. A satisfactory agreement between the results was obtained, such that the mathematical model can be used for future simulation of the operation of the pump and further optimization of the main components.
引用
收藏
页码:77 / 81
页数:4
相关论文
共 50 条
  • [1] Experimental Validation of a Numerical Model of an Axial Circulatory Assist Blood Pump
    Gouskov, A. M.
    Sorokin, F. D.
    Banin, E. P.
    Krupnin, A. E.
    Skoryukov, S., V
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2019, 53 (02): : 77 - 81
  • [2] Experimental and Numerical Investigation of an Axial Rotary Blood Pump
    Schuele, Chan Yong
    Thamsen, Bente
    Bluemel, Bastian
    Lommel, Michael
    Karakaya, Tamer
    Paschereit, Christian Oliver
    Affeld, Klaus
    Kertzscher, Ulrich
    ARTIFICIAL ORGANS, 2016, 40 (11) : E192 - E202
  • [3] Development of an implantable centrifugal blood pump for circulatory assist
    Wakisaka, Y
    Taenaka, Y
    Chikanari, K
    Okuzono, Y
    Endo, S
    Takano, H
    ASAIO JOURNAL, 1997, 43 (05) : M608 - M614
  • [4] COMPARISON AND EXPERIMENTAL VALIDATION OF TURBULENCE MODELS FOR AN AXIAL FLOW BLOOD PUMP
    Wang, Shuai
    Tan, Jianping
    Yu, Zheqin
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (08)
  • [5] Numerical simulation of an axial blood pump
    Chua, Leok Poh
    Su, Boyang
    Lim, Tau Meng
    Zhou, Tongming
    ARTIFICIAL ORGANS, 2007, 31 (07) : 560 - 570
  • [6] Pivot wear of a centrifugal blood pump developed for circulatory assist
    Takashi Yamane
    Katsunobu Nonaka
    Hisashi Miyoshi
    Osamu Maruyama
    Masahiro Nishida
    Ryo Kosaka
    Yoshiyuki Sankai
    Tatsuo Tsutsui
    Journal of Artificial Organs, 2008, 11 : 232 - 237
  • [7] Pivot wear of a centrifugal blood pump developed for circulatory assist
    Yamane, Takashi
    Nonaka, Katsunobu
    Miyoshi, Hisashi
    Maruyama, Osamu
    Nishida, Masahiro
    Kosaka, Ryo
    Sankai, Yoshiyuki
    Tsutsui, Tatsuo
    JOURNAL OF ARTIFICIAL ORGANS, 2008, 11 (04) : 232 - 237
  • [8] EXPERIMENTAL VALIDATION OF FLUID DYNAMIC NUMERICAL MODELS IN BLOOD PUMP SIMULATION
    Zhang, Jiafeng
    Zhang, Pei
    Fraser, Kate
    Griffith, Bartley P.
    Wu, Zhongjun J.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 575 - 576
  • [9] Intrathoracic and intraabdominal wall implantation of a centrifugal blood pump for circulatory assist
    Wakisaka, Y
    Taenaka, Y
    Chikanari, K
    Okuzono, Y
    Nishimura, T
    Endo, S
    Nakatani, T
    Takano, H
    ARTIFICIAL ORGANS, 1998, 22 (06) : 493 - 497
  • [10] Assessment of Hemolysis in a Ventricular Assist Axial Flow Blood Pump
    Gouskov A.M.
    Lomakin V.O.
    Banin E.P.
    Kuleshova M.S.
    Biomedical Engineering, 2016, 50 (4) : 233 - 236