Experimental Validation of a Numerical Model of an Axial Circulatory Assist Blood Pump

被引:0
|
作者
A. M. Gouskov
F. D. Sorokin
E. P. Banin
A. E. Krupnin
S. V. Skoryukov
机构
[1] Bauman Moscow State Technical University,
[2] Mechanical Engineering Research Institute of the Russian Academy of Sciences,undefined
[3] National Research Center “Kurchatov Institute”,undefined
来源
Biomedical Engineering | 2019年 / 53卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This study continues our systematic exploration of the design of an axial circulatory assist blood pump with a rotor on magnetic bearings. The work reported here addresses experimental validation of a numerical model of flow in the flow part of the axial blood pump. The study focuses on design of the test rig, design of experiments, and modeling of blood flow in the flow part of the pump using computational fluid dynamics. The working fluid was distilled water. The flow-pressure characteristics obtained experimentally were compared with those from mathematical modeling. A satisfactory agreement between the results was obtained, such that the mathematical model can be used for future simulation of the operation of the pump and further optimization of the main components.
引用
收藏
页码:77 / 81
页数:4
相关论文
共 50 条
  • [21] Numerical investigation on flow field and biocompatibility of an axial blood pump
    Zhu, Xianran
    Zhang, Mingyuan
    Liu, Haonan
    Zhang, Genguang
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2006, 40 (11): : 1290 - 1294
  • [22] NUMERICAL DESIGN OF A PARTIAL-SUPPORT AXIAL BLOOD PUMP
    Liu, Guangmao
    Jin, Donghai
    Wang, Mengyu
    Gui, Xingmin
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2019, VOL 3B, 2019,
  • [23] Numerical and Experimental Analysis of Vortex Pump with Various Axial Clearances
    Zhou, Ling
    Zhou, Chuan
    Bai, Ling
    Agarwal, Ramesh
    WATER, 2024, 16 (11)
  • [24] THE EXPERIMENTAL MODEL OF DISC-PUMP FOR MECHANICAL CIRCULATORY SUPPORT
    Chernyavskiy, A. M.
    Ruzmatov, T. M.
    Fomichev, A. V.
    Medvedev, A. E.
    Prikhodko, Y. M.
    Fomin, V. M.
    Fomichev, V. P.
    Chekhov, V. P.
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2016, 18 (04): : 93 - 101
  • [25] Interaction of an Idealized Cavopulmonary Circulation With Mechanical Circulatory Assist Using an Intravascular Rotary Blood Pump
    Bhavsar, Sonya S.
    Moskowitz, William B.
    Throckmorton, Amy L.
    ARTIFICIAL ORGANS, 2010, 34 (10) : 816 - 827
  • [26] An Experimental Study of Newtonian and Non-Newtonian Flow Dynamics in an Axial Blood Pump Model
    Hu, Qi-Hui
    Li, Jing-Yin
    Zhang, Ming-Yuan
    Zhu, Xian-Ran
    ARTIFICIAL ORGANS, 2012, 36 (04) : 429 - 433
  • [27] Progress in the development of a transcutaneously powered axial flow blood pump ventricular assist system
    Parnis, SM
    Conger, JL
    Fuqua, JM
    Jarvik, RK
    Inman, RW
    Tamez, D
    Macris, MP
    Moore, S
    Jacobs, G
    Sweeney, MJ
    Frazier, OH
    ASAIO JOURNAL, 1997, 43 (05) : M576 - M580
  • [28] An Experimental Validation of Numerical Model for Top-Hat Tubular Structure Subjected to Axial Crush
    Abdulqadir, Samer Fakhri
    Tarlochan, Faris
    APPLIED SCIENCES-BASEL, 2021, 11 (11):
  • [29] Numerical investigation on hydrodynamics and biocompatibility of a magnetically suspended axial blood pump
    Zhu, Xianran
    Zhang, Mingyuan
    Zhang, Genguang
    Liu, Haonan
    ASAIO JOURNAL, 2006, 52 (06) : 624 - 629
  • [30] NUMERICAL STUDIES OF AN AXIAL FLOW BLOOD PUMP WITH DIFFERENT DIFFUSER DESIGNS
    Su, Boyang
    Chua, Leok Poh
    Zhong, Liang
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2013, 13 (03)