Determination of the Asymmetry Parameter and Scattering Coefficient of Turbid Media from Spatially Resolved Reflectance Measurements

被引:0
|
作者
Matthew R. Jones
Yukio Yamada
机构
[1] Department of Aerospace & Mechanical Engineering,
[2] University of Arizona,undefined
[3] Biomechanics Division,undefined
[4] Mechanical Engineering Laboratory,undefined
[5] AIST-MITI,undefined
[6] Namiki,undefined
来源
Optical Review | 1998年 / 5卷
关键词
turbid media; optical properties; reflectance measurements; Monte Carlo;
D O I
暂无
中图分类号
学科分类号
摘要
We present a technique for determining the asymmetry parameter and scattering coefficient of turbid media from spatially resolved reflectance measurements. This technique will contribute to the development of medical applications in which it is necessary to predict the distribution and propagation of light in tissue. Based on Monte Carlo simulations, we derived correlations which relate the reduced scattering coefficient and the asymmetry parameter to the relative reflectance curve. Initial estimates of the optical properties are obtained from these correlations. Final values are obtained by adjusting the optical parameters and repeating the Monte Carlo simulations until the simulated reflectance pattern matches the measured reflectance pattern. Preliminary experimental results indicate that this technique can be used to determine the asymmetry parameter to within 10% and the reduced scattering coefficient to within 5%.
引用
收藏
页码:72 / 76
页数:4
相关论文
共 50 条
  • [31] Reliable determination of tissue optical properties from spatially resolved reflectance
    Gladytz, Thomas
    Hoppe, Alexander
    Cantow, Kathleen
    Pohlmann, Andreas
    Flemming, Bert
    Niendorf, Thoralf
    Seeliger, Erdmann
    Grosenick, Dirk
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES X, 2017, 10056
  • [32] Spatially Resolved Lateral Transmission Measurements to Characterize Changes in the Scattering Coefficient and the Anisotropy Factor
    Stocker, Sabrina
    Foschum, Florian
    Kienle, Alwin
    APPLIED SPECTROSCOPY, 2018, 72 (05) : 757 - 764
  • [33] Estimation of optical properties of turbid media using spatially resolved diffuse reflectance combined with LSTM-attention network
    Sun, Danni
    Wang, Xin
    Huang, Min
    Zhu, Qibing
    Qin, Jianwei
    OPTICS EXPRESS, 2023, 31 (06) : 10260 - 10272
  • [34] Localization of an absorber in a turbid semi-infinite medium by spatially resolved continuous-wave diffuse reflectance measurements
    Aksel, Ertugrul Burtecin
    Turkoglu, Ahu Nur
    Ercan, Ayse Ece
    Akin, Ata
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (08)
  • [35] Quantification of the reduced scattering coefficient and phase-function-dependent parameter γ of turbid media using multidiameter single fiber reflectance spectroscopy: experimental validation
    Gamm, U. A.
    Kanick, S. C.
    Sterenborg, H. J. C. M.
    Robinson, D. J.
    Amelink, A.
    OPTICS LETTERS, 2012, 37 (11) : 1838 - 1840
  • [36] Fast method of retrieving the asymmetry factor and scattering albedo from the maximum time-resolved reflectance of participating media
    Qi, Hong
    Ren, Ya-Tao
    Chen, Qin
    Ruan, Li-Ming
    APPLIED OPTICS, 2015, 54 (16) : 5234 - 5242
  • [37] Measuring the scattering coefficient of turbid media from two-photon microscopy
    Sevrain, David
    Dubreuil, Matthieu
    Leray, Aymeric
    Odin, Christophe
    Le Grand, Yann
    OPTICS EXPRESS, 2013, 21 (21): : 25221 - 25235
  • [38] Determination of chromophore concentrations from spatially resolved skin measurements
    Andree, Stefan
    Helfmann, Juergen
    Gersonde, Ingo
    CLINICAL AND BIOMEDICAL SPECTROSCOPY AND IMAGING II, 2011, 8087
  • [39] Determination of three optical properties from subdiffusive spatially resolved reflectance calculations
    Krauter, Philipp
    Reitzle, Dominik
    Geiger, Simeon
    Kienle, Alwin
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (07)
  • [40] Determination of tissue optical properties from spatially resolved relative diffuse reflectance
    Chen, YQ
    Lin, L
    Li, G
    Ye, WY
    Yu, QL
    ALT'03 INTERNATIONAL CONFERENCE ON ADVANCED LASER TECHNOLOGIES: BIOMEDICAL OPTICS, 2003, 5486 : 85 - 92