Synchrophasors-Based Transmission Line Protection in the Presence of STATCOM

被引:7
|
作者
Ghorbani A. [1 ]
Ghorbani M. [2 ]
Ebrahimi S.Y. [3 ]
机构
[1] Department of Electrical Engineering, Abhar Branch, Islamic Azad University, Abhar
[2] Department of Electrical, Biomedical and Mechatronics Engineering, Qazvin Branch, Islamic Azad University, Qazvin
[3] Department of Electrical Engineering, Hidaj Branch, Islamic Azad University, Hidaj
关键词
Flexible AC transmission system (FACTS) controllers; Ground distance relay; Phasor measurement units (PMUs); Static synchronous compensator (STATCOM);
D O I
10.1007/s40313-016-0288-5
中图分类号
学科分类号
摘要
Distance relay identifies the type and location of fault by measuring the transmission line impedance. However, any other factors that cause miscalculating the measured impedance make the relay detect the fault in incorrect location or do not detect the fault at all. One of the important factors which directly increases the measured impedance by the relay is fault resistance. Another factor that indirectly changes the impedance of the transmission line is static synchronous compensator (STATCOM). When a fault occurs, measured signals by the relay change due to the variation of current injected by the STATCOM and it makes the calculated impedance to be incorrect. This paper provides a method based on the combination of distance and differential protection. At first, faulty transmission line is detected according to the current data of buses. After that the fault location is calculated using the proposed algorithm on the transmission line. This algorithm is based on active power calculation of the buses. Fault resistance is calculated from the active powers, and its effect will be deducted from calculated impedance by the algorithm. Furthermore, by choosing the appropriate data bus, the effect of STATCOM is eliminated and fault location will be detected. © 2016, Brazilian Society for Automatics--SBA.
引用
收藏
页码:147 / 157
页数:10
相关论文
共 50 条
  • [31] Performance comparison of PI & ANN based STATCOM for 132 KV transmission line
    Shinde, Sagar U.
    Sharmila, M.
    Patil, Roopali S.
    Malkhede, Dinesh V.
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 2730 - 2734
  • [32] A DWT Based Differential Relaying STATCOM Integrated Wind Fed Transmission Line
    Mishra, S. K.
    Tripathy, L. N.
    Swain, S. C.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2018, 8 (01): : 476 - 487
  • [33] System Integrity Protection Schems for Future Power Transmission System Using Synchrophasors
    Skok, Srdjan
    Ivankovic, Igor
    2019 INTERNATIONAL CONFERENCE ON SMART GRID SYNCHRONIZED MEASUREMENTS AND ANALYTICS (SGSMA), 2019,
  • [34] A New Adaptive Impedance-Based LOE Protection of Synchronous Generator in the Presence of STATCOM
    Yaghobi, Hamid
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (06) : 2489 - 2499
  • [35] Transmission line protection
    Horowitz, Stanley H.
    Power System Stability and Control, Third Edition, 2017, : 3 - 1
  • [36] Considerations on Distance Relay Setting for Transmission Line with STATCOM
    Zhang, Wen-Hao
    Lee, Seung-Jae
    Choi, Myeon-Song
    Oda, Shigeto
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [37] Setting Considerations of Distance Relay for Transmission Line with STATCOM
    Zhang, Wen-Hao
    Lee, Seung-Jae
    Choi, Myeon-Song
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2010, 5 (04) : 522 - 529
  • [38] Relay protection system of transmission line based on AI
    Zheng, Xiangyu
    Jia, Rong
    Gong, Linling
    Aisikaer
    Ma, Xiping
    Dang, Jian
    Lv, Zhihan
    PLOS ONE, 2021, 16 (04):
  • [39] A Protection Scheme of Transmission Line Based on Nature Frequency
    Wang, X. G.
    Huang, S. F.
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 79 - 83
  • [40] Transmission line distance protection based on wavelet transform
    Osman, AH
    Malik, OP
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (02) : 515 - 523