MR-guided biopsies with a newly designed cordless coil in an open low-field system: Initial findings

被引:0
|
作者
Stephan Zangos
Theodor Vetter
Frank Huebner
Montu Tuwari
Florian Mayer
Katrin Eichler
M.-L. Hansmann
A. Wetter
C. Herzog
Thomas J. Vogl
机构
[1] J. W. Goethe-University Frankfurt,Institute for Diagnostic and Interventional Radiology
[2] Siemens AG,Department of Pathology
[3] Medical Solutions,undefined
[4] MR Applications Development,undefined
[5] J. W. Goethe-University Frankfurt,undefined
来源
European Radiology | 2006年 / 16卷
关键词
Biopsies; Magnetic resonance (MR); Guidance; Interventional procedures;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a newly designed cordless coil in an open low-field magnetic resonance (MR) system. Eleven patients were biopsied using a low-field system (0.2 T, Magnetom Concerto, Siemens) by using the new cordless coil (Siemens). The biopsies were performed in different organ systems [liver (n=7), abdomen (n=1), shoulder (n=1), pelvis (n=1) and hip (n=1)]. The procedures were guided using T1-weighted FLASH (fast low-angle shot) sequences. The lesions were biopsied using the coaxial technique through a 15-gauge puncture needle with a 16-gauge biopsy handy. Coil handling, image quality and complications were evaluated. Imaging quality and visualization of the lesions were optimal up to a penetration depth of 9 cm. In all cases the biopsy procedures were successfully performed with MR guidance without any complications. Pathological findings revealed seven cases of malignant tissue and four cases of non-malignant tissue. The use of the cordless coil allows improved patient access during the biopsy and an improved handling of the coil system. MR-guided biopsy using the novel cordless coil system can be performed safely and precisely with easy handling of the coil. This coil concept, however, is restricted to special indications.
引用
收藏
页码:2044 / 2050
页数:6
相关论文
共 49 条
  • [31] Inverse design of an organ-oriented RF coil for open, vertical-field, MR-guided, focused ultrasound surgery
    Xin, Xuegang
    Han, Jijun
    Feng, Yanqiu
    Feng, Qianjin
    Chen, Wufan
    MAGNETIC RESONANCE IMAGING, 2012, 30 (10) : 1519 - 1526
  • [32] MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking
    Roberto Blanco Sequeiros
    Heli Reinikainen
    Andreas M. Blanco Sequeiros
    Teuvo Vaara
    Risto Ojala
    Eija Pääkkö
    Osmo Tervonen
    European Radiology, 2007, 17
  • [33] MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking
    Sequeiros, Roberto Blanco
    Reinikainen, Heli
    Sequeiros, Andreas M. Blanco
    Vaara, Teuvo
    Ojala, Risto
    Paakko, Eija
    Tervonen, Osmo
    EUROPEAN RADIOLOGY, 2007, 17 (03) : 813 - 819
  • [34] MR-guided tranvaginal and percutaneous cryosurgery of uterine fibroid using horizontal magnetic open-type MR system: Initial experiences
    Dohi, MT
    Mogami, T
    Harada, J
    Fukuda, K
    Yasuda, M
    Kobayashi, S
    RADIOLOGY, 2002, 225 : 128 - 128
  • [35] Initial phantom studies for an office-based low-field MR system for prostate biopsy
    Chiragzada, Selin
    Hellman, Eva
    Michael, Duncan
    Narayanan, Ram
    Nacev, Aleksandar
    Kumar, Dinesh
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2021, 16 (05) : 741 - 748
  • [36] Low-field MR arthrography of the shoulder: early results using an open 0.2 T MR system.
    Low, R
    Kreitner, KF
    Runkel, M
    Zollner, J
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (04): : 316 - 322
  • [37] Initial phantom studies for an office-based low-field MR system for prostate biopsy
    Selin Chiragzada
    Eva Hellman
    Duncan Michael
    Ram Narayanan
    Aleksandar Nacev
    Dinesh Kumar
    International Journal of Computer Assisted Radiology and Surgery, 2021, 16 : 741 - 748
  • [38] MR imaging-guided biopsies in the head and neck region: A comparative evaluation of low field open and high field closed MR systems
    Borges, A
    Villablanca, JP
    Lufkin, RB
    RADIOLOGY, 1997, 205 : 1643 - 1643
  • [39] Validation of An Automatic ACR Phantom Quality Assurance Tool for the Low-Field MR Guided Radiotherapy System
    Gao, Y.
    Lotey, R.
    Hu, P.
    Yang, Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E670 - E670
  • [40] Setting up MR compatibility of a commercial stereo-localization system for low-field open MR interventional procedures
    Romain Viard
    Maximilien Vermandel
    Jean Rousseau
    International Journal of Computer Assisted Radiology and Surgery, 2009, 4 : 65 - 69