Initial phantom studies for an office-based low-field MR system for prostate biopsy

被引:4
|
作者
Chiragzada, Selin [1 ]
Hellman, Eva [1 ]
Michael, Duncan [1 ]
Narayanan, Ram [1 ]
Nacev, Aleksandar [1 ]
Kumar, Dinesh [1 ]
机构
[1] Promaxo Inc, Oakland, CA 94607 USA
关键词
Targeted prostate biopsy; Low-field MRI; Office-based MRI; Navigation accuracy; Prostate cancer; MR-guided biopsy; ULTRASOUND; BRACHYTHERAPY; ACCURACY; GUIDANCE; FUSION; TIME;
D O I
10.1007/s11548-021-02364-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Prostate cancer is the second most prevalent cancer in US men, with about 192,000 new cases and 33,000 deaths predicted for 2020. With only a 31% 5-year survival rate for patients with an initial diagnosis of stage-four prostate cancer, the necessity for early screening and diagnosis is clear. In this paper, we present navigation accuracy results for Promaxo's MR system intended to be used in a physician's office for image-guided transperineal prostate biopsy. Methods The office-based low-field MR system was used to acquire images of prostate phantoms with needles inserted through a transperineal template. Coordinates of the estimated sample core locations in the office-based MR system were compared to ground truth needle coordinates identified in a 1.5T external reference scan. The error was measured as the distance between the planned target and the ground truth core center and as the shortest perpendicular distance between the planned target and the ground truth trajectory of the whole core. Results The average error between the planned target and the ground truth core center was 2.57 +/- 1.02 mm, [1.93-3.21] 95% CI. The average error between the planned target to the actual core segment was 2.05 +/- 1.24 mm, [1.53-2.56] 95% CI. Conclusion The average navigation errors were below the clinically significant threshold of 5 mm. The initial phantom results demonstrate the feasibility of the office-based system for prostate biopsy.
引用
收藏
页码:741 / 748
页数:8
相关论文
共 50 条
  • [1] Initial phantom studies for an office-based low-field MR system for prostate biopsy
    Selin Chiragzada
    Eva Hellman
    Duncan Michael
    Ram Narayanan
    Aleksandar Nacev
    Dinesh Kumar
    International Journal of Computer Assisted Radiology and Surgery, 2021, 16 : 741 - 748
  • [2] Office-Based, Single-Sided, Low-Field MRI-Guided Prostate Biopsy
    Satya, Poorvi
    Adams, John, Jr.
    Venkataraman, Srirama S.
    Kumar, Dinesh
    Narayanan, Ram
    Nacev, Aleksandar
    Macaluso, Joseph N., Jr.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (05)
  • [3] Advantageous Detection of Significant Prostate Cancer Using a Low-Field, Office-Based MRI System
    Chiragzada, Selin
    Satya, Poorvi
    Macaluso Jr, Joseph N.
    Venkataraman, Srirama S.
    Adams Jr, John
    Nacev, Aleksandar N.
    Kumar, Dinesh
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (12)
  • [4] MR-guided biopsy of musculoskeletal lesions in a low-field system
    Koenig, CW
    Duda, SH
    Truebenbach, J
    Schott, UG
    Maurer, F
    Claussen, CD
    Pereira, PL
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (05) : 761 - 768
  • [5] VALUE OF TARGETED BIOPSY IN DETECTING PROSTATE CANCER USING AN OFFICE-BASED MR-US FUSION DEVICE
    Sonn, Geoffrey A.
    Natarajan, Shyam
    Margolis, Daniel
    Macairan, Malu
    Lieu, Patricia
    Huang, Jiaoti
    Dorey, Frederick J.
    Marks, Leonard S.
    JOURNAL OF UROLOGY, 2012, 187 (04): : E829 - E829
  • [6] ARTEMIS: AN OFFICE-BASED DEVICE FOR MRI FUSION AND TARGETED PROSTATE BIOPSY
    Marks, Leonard
    Natarajan, Shyam
    Margolis, Daniel
    Huang, Jiaoti
    Kumar, Dinesh
    Narayanan, Ramkrishnan
    Bentley, Rob
    Valley, Grass
    Macairan, Maria Luz
    Lieu, Patricia
    JOURNAL OF UROLOGY, 2011, 185 (04): : E928 - E929
  • [7] Office-based low-field extremity magnetic resonance imaging: Is the glass half empty or half full?
    Yocum, DE
    Conaghan, PG
    Olech, E
    Peterfy, CG
    ARTHRITIS AND RHEUMATISM, 2006, 54 (04): : 1048 - 1050
  • [8] Demystifying prostate saturation biopsy: Making the case for office-based prostate cancer diagnosis
    Kefer, J. C.
    Jones, J. S.
    JOURNAL OF ENDOUROLOGY, 2006, 20 : A340 - A340
  • [9] Validation of An Automatic ACR Phantom Quality Assurance Tool for the Low-Field MR Guided Radiotherapy System
    Gao, Y.
    Lotey, R.
    Hu, P.
    Yang, Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E670 - E670
  • [10] AN IN-VITRO STUDY AT LOW-FIELD FOR MR GUIDANCE OF A BIOPSY NEEDLE
    ARBOGASTRAVIER, S
    GANGI, A
    CHOQUET, P
    BRUNOT, B
    CONSTANTINESCO, A
    MAGNETIC RESONANCE IMAGING, 1995, 13 (02) : 321 - 324