Homogeneous electrogenerated chemiluminescence immunoassay for the detection of biomarkers by magnetic preconcentration on a magnetic electrode

被引:0
|
作者
Yuxi Wei
Yue Wang
Jiawei Wang
Xiaolin Yang
Honglan Qi
Qiang Gao
Chengxiao Zhang
机构
[1] Shaanxi Normal University,Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering
来源
关键词
Homogeneous immunoassays; Electrogenerated chemiluminescence; Magnetic electrode; Magnetic beads; D-Dimer;
D O I
暂无
中图分类号
学科分类号
摘要
A homogeneous electrogenerated chemiluminescence (ECL) immunoassay for highly sensitive quantification of specific biomarkers based on immunomagnetic beads and homogeneous detection on a magnetic electrode was developed, for the first time. The magnetic electrode is made of a glassy carbon electrode and a series of ring permanent magnets. D-Dimer antigen was taken as a model analyte while biotinylated D-dimer antibody bound on the streptavidin-coated magnetic beads was utilized as a magnetic capture probe and ruthenium complex-labeled D-dimer antibody was employed as an ECL probe. After a fixed amount of magnetic capture probe and the ECL probe was introduced into analyte D-dimer solution, the “sandwich” immunoconjugates on the magnetic beads were formed in tested solution and then magnetically concentrated on the surface of the magnetic electrode. The homogeneous ECL immunoassay for quantification of specific biomarker was directly carried out in the presence of co-reactant tripropylamine. The low detection limit of 1 ng/mL in magnetic enrich time of 2 min and the good magnetic regeneration for the detection of D-dimer were achieved. The magnetic bead shield ECL emission was extensively discussed. This work demonstrates that the homogeneous (separation-free) ECL immunoassay using magnetic beads and magnetic electrode is a promising approach to quantify the biomarkers with high sensitivity and selectivity and in a short time. This approach can be easily extended to ECL and electrochemical biosensing for other biomarkers.
引用
收藏
页码:4203 / 4211
页数:8
相关论文
共 50 条
  • [21] Microchip electrophoresis coupled with on-line magnetic separation and chemiluminescence detection for multiplexed immunoassay
    Huang, Yong
    Zhao, Shulin
    Shi, Ming
    Liu, Jinwen
    Liang, Hong
    ELECTROPHORESIS, 2012, 33 (07) : 1198 - 1204
  • [22] Influence of exposed magnetic nanoparticles and their application in chemiluminescence immunoassay
    Zhang, Zhi
    Guan, Yueping
    Xia, Tingting
    Du, Jiao
    Li, Tao
    Sun, Zongying
    Guo, Chen
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2017, 520 : 335 - 342
  • [23] An Origami Paper-Based Biosensor for Allergen Detection by Chemiluminescence Immunoassay on Magnetic Microbeads
    Lazzarini, Elisa
    Pace, Andrea
    Trozzi, Ilaria
    Zangheri, Martina
    Guardigli, Massimo
    Calabria, Donato
    Mirasoli, Mara
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [24] Development of a rapid and ultrasensitive magnetic chemiluminescence immunoassay for the detection of adiponectin and its clinical application
    Li, Jiexia
    Fan, Zhuqiao
    Chen, Hanqi
    Da Costa, Ernestina Maria
    Zhou, Xiaomian
    Yu, Nan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 241
  • [25] Nanobody-based magnetic chemiluminescence immunoassay for one-pot detection of ochratoxin A
    Zuo, Hu
    Wang, Xinyang
    Liu, Wentao
    Chen, Zongfen
    Liu, Ruonan
    Yang, Han
    Xia, Chunyan
    Xie, Jinli
    Sun, Tieqiang
    Ning, Baoan
    TALANTA, 2023, 258
  • [26] Ultrasensitive Eletrogenerated Chemiluminescence Immunoassay by Magnetic Nanobead Amplification
    Li, Mingyue
    Sun, Yuming
    Chen, Li
    Li, Lu
    Zou, Guizheng
    Zhang, Xiaoli
    Jin, Wenrui
    ELECTROANALYSIS, 2010, 22 (03) : 333 - 337
  • [27] Electrogenerated chemiluminescence of luminol at a boron-doped diamond electrode for the detection of hypochlorite
    Rahmawati, Isnaini
    Saepudin, Endang
    Fiorani, Andrea
    Einaga, Yasuaki
    Ivandini, Tribidasari A.
    ANALYST, 2022, 147 (12) : 2696 - 2702
  • [28] Detection of Ferrocenemethanol and Molecular Oxygen Based on Electrogenerated Chemiluminescence Quenching at a Bipolar Electrode
    Wang, Tanyu
    Fan, Sanjun
    Erdmann, Ruby
    Shannon, Curtis
    LANGMUIR, 2013, 29 (51) : 16040 - 16044
  • [29] Application of Magnetic Particles-Based Chemiluminescence Enzyme Immunoassay by Magnetic Bar Transfer in the Detection of Herpes Simplex Virus
    Yang, Ping
    An, Xiang Q.
    Xu, Hongpan
    Xia, Yanyan
    Liu, Chang
    Wang, Su
    Di, Kaili
    Li, Zhiyang
    Shen, Han
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2020, 12 (05) : 633 - 641
  • [30] Establishment of a homogeneous chemiluminescence immunoassay for cat dander sIgE antibody detection
    Sun, Yuanmin
    Na, Ren
    Zhu, Lina
    Yang, Xiaohui
    Tan, Xin
    Zheng, Lisheng
    Li, Huiqiang
    Yu, Yang
    JOURNAL OF ASTHMA, 2024, 61 (01) : 10 - 19