A homogeneous electrogenerated chemiluminescence (ECL) immunoassay for highly sensitive quantification of specific biomarkers based on immunomagnetic beads and homogeneous detection on a magnetic electrode was developed, for the first time. The magnetic electrode is made of a glassy carbon electrode and a series of ring permanent magnets. D-Dimer antigen was taken as a model analyte while biotinylated D-dimer antibody bound on the streptavidin-coated magnetic beads was utilized as a magnetic capture probe and ruthenium complex-labeled D-dimer antibody was employed as an ECL probe. After a fixed amount of magnetic capture probe and the ECL probe was introduced into analyte D-dimer solution, the “sandwich” immunoconjugates on the magnetic beads were formed in tested solution and then magnetically concentrated on the surface of the magnetic electrode. The homogeneous ECL immunoassay for quantification of specific biomarker was directly carried out in the presence of co-reactant tripropylamine. The low detection limit of 1 ng/mL in magnetic enrich time of 2 min and the good magnetic regeneration for the detection of D-dimer were achieved. The magnetic bead shield ECL emission was extensively discussed. This work demonstrates that the homogeneous (separation-free) ECL immunoassay using magnetic beads and magnetic electrode is a promising approach to quantify the biomarkers with high sensitivity and selectivity and in a short time. This approach can be easily extended to ECL and electrochemical biosensing for other biomarkers.
引用
收藏
页码:4203 / 4211
页数:8
相关论文
共 50 条
  • [1] Homogeneous electrogenerated chemiluminescence immunoassay for the detection of biomarkers by magnetic preconcentration on a magnetic electrode
    Wei, Yuxi
    Wang, Yue
    Wang, Jiawei
    Yang, Xiaolin
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (18) : 4203 - 4211
  • [2] Homogeneous electrogenerated chemiluminescence immunoassay for the determination of digoxin
    Qi, HL
    Zhang, CX
    ANALYTICA CHIMICA ACTA, 2004, 501 (01) : 31 - 35
  • [3] ELECTROGENERATED CHEMILUMINESCENCE .4. MAGNETIC FIELD EFFECTS ON ELECTROGENERATED CHEMILUMINESCENCE OF SOME ANTHRACENES
    FAULKNER, LR
    BARD, AJ
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1969, 91 (01) : 209 - &
  • [4] Homogeneous electrogenerated chemiluminescence immunoassay using a luminol-labeled digoxin hapten
    Zhang, CX
    Zhang, HH
    Feng, ML
    ANALYTICAL LETTERS, 2003, 36 (06) : 1103 - 1114
  • [5] Abnormal Magnetic Field Effects on Electrogenerated Chemiluminescence
    Haiping Pan
    Yan Shen
    Hongfeng Wang
    Lei He
    Bin Hu
    Scientific Reports, 5
  • [6] Abnormal Magnetic Field Effects on Electrogenerated Chemiluminescence
    Pan, Haiping
    Shen, Yan
    Wang, Hongfeng
    He, Lei
    Hu, Bin
    SCIENTIFIC REPORTS, 2015, 5
  • [7] Electrogenerated chemiluminescence biosensor array for the detection of multiple AMI biomarkers
    Yang, Xiaolin
    Zhao, Ying
    Sun, Lijuan
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 257 : 60 - 67
  • [8] Electrogenerated Chemiluminescence Bioanalytic System Based on Biocleavage of Probes and Homogeneous Detection
    Zhang, Jing
    Qi, Honglan
    Li, Zhejian
    Zhang, Ni
    Gao, Qiang
    Zhang, Chengxiao
    ANALYTICAL CHEMISTRY, 2015, 87 (13) : 6510 - 6515
  • [9] Sensitive detection of cardiac biomarkers using a magnetic microbead immunoassay
    Woolley, Christine F.
    Hayes, Mark A.
    ANALYTICAL METHODS, 2015, 7 (20) : 8632 - 8639
  • [10] An ultrasensitive electrogenerated chemiluminescence-based immunoassay for specific detection of Zika virus
    Dhiraj Acharya
    Pradip Bastola
    Linda Le
    Amber M. Paul
    Estefania Fernandez
    Michael S. Diamond
    Wujian Miao
    Fengwei Bai
    Scientific Reports, 6