Experimental study of the depth dose distributions produced by an electron beam

被引:0
|
作者
A. V. Belousov
A. A. Kurakin
A. P. Chernyaev
机构
[1] Moscow State University,Faculty of Physics
[2] Moscow State University,Skobeltsyn Research Institute of Nuclear Physics
关键词
87.50.Gi;
D O I
暂无
中图分类号
学科分类号
摘要
Changes in the amplitude and position of the maximum of the depth dose distribution produced by the electron beams with energies of 25 and 50 MeV in the presence of a transverse magnetic field with an induction of 05–1.2 T are confirmed experimentally. A model for the analytical calculation of the depth dose distribution is proposed. The model is based on the theory of electron-photon showers. A good agreement is observed between the experimental distribution and the distribution calculated with the use of the proposed model.
引用
收藏
页码:559 / 562
页数:3
相关论文
共 50 条
  • [21] Changes to dose at surface and shifts of dose distributions at depth through dry and wet wound dressings for photon and electron beam radiotherapy
    Ciara Mac Nally
    Simon Woodings
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 245 - 250
  • [22] Dose distributions and percentage depth dose measurements for a total skin electron therapy
    Licona, I.
    Figueroa-Medina, E.
    Gamboa-deBuen, I.
    RADIATION MEASUREMENTS, 2017, 106 : 365 - 372
  • [23] The effects of collimation designs on the depth dose distributions of electron beams
    Goksel, Evren Ozan
    Okutan, Murat
    Cakir, Aydin
    Bilge, Hatice
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2008, 23 (04): : 182 - 188
  • [24] MONTE-CARLO CALCULATION OF ELECTRON DEPTH DOSE DISTRIBUTIONS
    SCHRIBER, SO
    FUNK, LW
    MOWCHENKO, JT
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 573 - 573
  • [25] Monte Carlo study of electron dose distributions produced by the elekta precise linear accelerator
    Nedaie, Hassan Ali
    Mosleh-Shirazi, M. A.
    Shariary, M.
    Gharaati, H.
    Allahverdi, M.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2006, 11 (06) : 287 - 292
  • [26] ELECTRON DOSE DISTRIBUTIONS IN EXPERIMENTAL PHANTOMS - A COMPARISON WITH 2D PENCIL BEAM CALCULATIONS
    CYGLER, J
    BATTISTA, JJ
    SCRIMGER, JW
    MAH, E
    ANTOLAK, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09): : 1073 - 1086
  • [27] Electron beam depth dose distributions in 3D-printed samples with different material filling factor
    Stuchebro, S., V
    Bulavskaya, A.
    Cherepennikov, Y.
    Gavrikov, B.
    Miloichikova, I.
    Turgunova, N.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S799 - S800
  • [28] First experimental-based characterization of oxygen ion beam depth dose distributions at the Heidelberg Ion-Beam Therapy Center
    Kurz, C.
    Mairani, A.
    Parodi, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (15): : 5017 - 5034
  • [29] Simulation and experimental verification of dose distributions of electron beams
    Semnicka, J.
    Kluson, J.
    RADIOPROTECTION, 2012, 47 (01) : 79 - 91
  • [30] PENCIL-BEAM REDEFINITION ALGORITHM FOR ELECTRON DOSE DISTRIBUTIONS
    SHIU, AS
    HOGSTROM, KR
    MEDICAL PHYSICS, 1991, 18 (01) : 7 - 18