First experimental-based characterization of oxygen ion beam depth dose distributions at the Heidelberg Ion-Beam Therapy Center

被引:62
|
作者
Kurz, C.
Mairani, A.
Parodi, K.
机构
[1] Heidelberg Univ Clin, Heidelberg Ion Beam Therapy Ctr, Heidelberg, Germany
[2] Heidelberg Univ Clin, Dept Radiat Oncol, Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 15期
关键词
SCANNED PROTON; FLUKA; MODELS; WATER;
D O I
10.1088/0031-9155/57/15/5017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Over the last decades, the application of proton and heavy-ion beams to external beam radiotherapy has rapidly increased. Due to the favourable lateral and depth dose profile, the superposition of narrow ion pencil beams may enable a highly conformal dose delivery to the tumour, with better sparing of the surrounding healthy tissue in comparison to conventional radiation therapy with photons. To fully exploit the promised clinical advantages of ion beams, an accurate planning of the patient treatments is required. The clinical treatment planning system (TPS) at the Heidelberg Ion-Beam Therapy Center (HIT) is based on a fast performing analytical algorithm for dose calculation, relying, among others, on laterally integrated depth dose distributions (DDDs) simulated with the FLUKA Monte Carlo (MC) code. Important input parameters of these simulations need to be derived from a comparison of the simulated DDDs with measurements. In this work, the first measurements of O-16 ion DDDs at HIT are presented with a focus on the determined Bragg peak positions and the understanding of factors influencing the shape of the distributions. The measurements are compared to different simulation approaches aiming to reproduce the acquired data at best. A simplified geometrical model is first used to optimize important input parameters, not known a priori, in the simulations. This method is then compared to a more realistic, but also more time-consuming simulation approach better accounting for the experimental set-up and the measuring process. The results of this work contributed to a pre-clinical oxygen ion beam database, which is currently used by a research TPS for corresponding radio-biological cell experiments. A future extension to a clinical database used by the clinical TPS at HIT is foreseen. As a side effect, the performed investigations showed that the typical water equivalent calibration approach of experimental data acquired with water column systems leads to slight deviations between the experimentally determined and the real Bragg peak positions. For improved accuracy, the energy dependence of the stopping power, and herewith the water equivalent thickness, of the material downstream of the water tank should be considered in the analysis of measured data.
引用
收藏
页码:5017 / 5034
页数:18
相关论文
共 50 条
  • [1] STATUS OF THE HEIDELBERG ION-BEAM THERAPY CENTRE
    Ellerbrock, M.
    Jakel, O.
    Heeg, P.
    Ackermann, B.
    Winter, M.
    Parodi, K.
    Brons, S.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S440 - S441
  • [2] DEPTH-DOSE CHARACTERISTIC OF OXYGEN ION-BEAM AT BEVATRON
    MACCABEE, HD
    LYMAN, JT
    WELCH, G
    TOBIAS, CA
    CHATTERJ.A
    HOWARD, J
    CURTIS, SB
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 694 - &
  • [3] Progress in ion source injector development at the ion beam therapy center (Heidelberg Ion Beam Therapy Center)
    Winkelmann, T.
    Cee, R.
    Haberer, T.
    Naas, B.
    Peters, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02):
  • [4] EXPERIMENTAL CHARACTERIZATION, MODELING AND IN-VIVO IMAGING TO FOSTER HIGH PRECISION ION BEAM THERAPY AT THE HEIDELBERG ION BEAM THERAPY CENTER
    Parodi, K.
    Bauer, J.
    Frey, K.
    Kurz, C.
    Mairani, A.
    Rinaldi, I.
    Schwaab, J.
    Sommerer, F.
    Unholtz, D.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S34 - S35
  • [5] Carbon ion therapy applied in raster scanning technique for hepatocellular carcinoma - first results from the Heidelberg Ion-Beam Therapy Center
    Habermehl, D.
    Herfarth, K. K.
    Ganten, T.
    Ganten, M.
    Brecht, I
    Haertig, M.
    Welzel, T.
    Ecker, S.
    Jaeckel, O.
    Haberer, T.
    Parodi, K.
    Schirmacher, P.
    Buechler, M. W.
    Debus, J.
    Combs, S. E.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 99 - 99
  • [6] Hadron minibeam radiation therapy: feasibility study at the Heidelberg Ion-Beam Therapy Center (HIT)
    Martinez-Rovira, I.
    Brons, S.
    Prezado, Y.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S70 - S71
  • [7] STRATEGIES FOR CARBON ION TREATMENT PLANNING AT THE HEIDELBERG ION-BEAM THERAPY CENTRE
    Ecker, S.
    Ackermann, B.
    Brons, S.
    Ellerbrock, M.
    Heeg, P.
    Henkner, K.
    Nairz, O.
    Winter, M.
    Jaekel, O.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S541 - S541
  • [8] The intensity feedback system at Heidelberg Ion-Beam Therapy Centre
    Schoemers, Christian
    Feldmeier, Eike
    Naumann, Jakob
    Panse, Ralf
    Peters, Andreas
    Haberer, Thomas
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 795 : 92 - 99
  • [9] Medical physics research at the Heidelberg ion beam therapy center
    Jaekel, O.
    Ellerbrock, M.
    Heeg, P.
    Ackermann, B.
    Winter, M.
    Brons, S.
    Parodi, K.
    Haberer, T.
    Karger, C. P.
    Bert, C.
    Kraemer, M.
    Debus, J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 : 21 - 22
  • [10] Optimization of the spill quality for the hadron therapy at the Heidelberg Ion-Beam Therapy Centre
    Cortés García, E.C.
    Feldmeier, E.
    Galonska, M.
    Schömers, C.
    Hun, M.
    Brons, S.
    Cee, R.
    Scheloske, S.
    Peters, A.
    Haberer, Th.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022, 1040