First experimental-based characterization of oxygen ion beam depth dose distributions at the Heidelberg Ion-Beam Therapy Center

被引:62
|
作者
Kurz, C.
Mairani, A.
Parodi, K.
机构
[1] Heidelberg Univ Clin, Heidelberg Ion Beam Therapy Ctr, Heidelberg, Germany
[2] Heidelberg Univ Clin, Dept Radiat Oncol, Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 15期
关键词
SCANNED PROTON; FLUKA; MODELS; WATER;
D O I
10.1088/0031-9155/57/15/5017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Over the last decades, the application of proton and heavy-ion beams to external beam radiotherapy has rapidly increased. Due to the favourable lateral and depth dose profile, the superposition of narrow ion pencil beams may enable a highly conformal dose delivery to the tumour, with better sparing of the surrounding healthy tissue in comparison to conventional radiation therapy with photons. To fully exploit the promised clinical advantages of ion beams, an accurate planning of the patient treatments is required. The clinical treatment planning system (TPS) at the Heidelberg Ion-Beam Therapy Center (HIT) is based on a fast performing analytical algorithm for dose calculation, relying, among others, on laterally integrated depth dose distributions (DDDs) simulated with the FLUKA Monte Carlo (MC) code. Important input parameters of these simulations need to be derived from a comparison of the simulated DDDs with measurements. In this work, the first measurements of O-16 ion DDDs at HIT are presented with a focus on the determined Bragg peak positions and the understanding of factors influencing the shape of the distributions. The measurements are compared to different simulation approaches aiming to reproduce the acquired data at best. A simplified geometrical model is first used to optimize important input parameters, not known a priori, in the simulations. This method is then compared to a more realistic, but also more time-consuming simulation approach better accounting for the experimental set-up and the measuring process. The results of this work contributed to a pre-clinical oxygen ion beam database, which is currently used by a research TPS for corresponding radio-biological cell experiments. A future extension to a clinical database used by the clinical TPS at HIT is foreseen. As a side effect, the performed investigations showed that the typical water equivalent calibration approach of experimental data acquired with water column systems leads to slight deviations between the experimentally determined and the real Bragg peak positions. For improved accuracy, the energy dependence of the stopping power, and herewith the water equivalent thickness, of the material downstream of the water tank should be considered in the analysis of measured data.
引用
收藏
页码:5017 / 5034
页数:18
相关论文
共 50 条
  • [21] OXYGEN ION-BEAM MODIFICATION OF GAAS
    DENG, XC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 209 (MAY): : 657 - 661
  • [23] Experimental methods in radioactive ion-beam target/ion source development and characterization
    Welton, RF
    Alton, GD
    Cui, B
    Murray, SN
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (08): : 2892 - 2897
  • [24] Current Status of 4D Offline PET-Based Treatment Verification at the Heidelberg Ion-Beam Therapy Center
    Kurz, Christopher
    Bauer, Julia
    Unholtz, Daniel
    Gianoli, Chiara
    Combs, Stephanie E.
    Debus, Juergen
    Richter, Daniel
    Kaderka, Robert
    Bert, Christoph
    Stuetzer, Kristin
    Baroni, Guido
    Parodi, Katia
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [25] Patient position verification in ion-beam therapy using ion-beam radiography and fiducial markers
    Huber, Lucas
    Telsemeyer, Julia
    Martisikova, Maria
    Jaekel, Oliver
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [26] ION-BEAM CHARACTERIZATION OF LASER MIRRORS
    BEERY, JG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 24-5 : 603 - 607
  • [27] Carbon Ion Radiation Therapy: One Decade of Research and Clinical Experience at Heidelberg Ion Beam Therapy Center
    Eichkorn, Tanja
    Koenig, Laila
    Held, Thomas
    Naumann, Patrick
    Harrabi, Semi
    Ellerbrock, Malte
    Herfarth, Klaus
    Haberer, Thomas
    Debus, Juergen
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : 597 - 609
  • [28] OXYGEN ION-BEAM ETCHING FOR PATTERN TRANSFER
    GOKAN, H
    ITOH, M
    ESHO, S
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1984, 2 (01): : 34 - 37
  • [29] Adjustment procedure for beam alignment in scanned ion-beam therapy
    Saraya, Y.
    Takeshita, E.
    Furukawa, T.
    Hara, Y.
    Mizushima, K.
    Saotome, N.
    Tansho, R.
    Shirai, T.
    Noda, K.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (06) : 948 - 952
  • [30] Adjustment procedure for beam alignment in scanned ion-beam therapy
    Y. Saraya
    E. Takeshita
    T. Furukawa
    Y. Hara
    K. Mizushima
    N. Saotome
    R. Tansho
    T. Shirai
    K. Noda
    Journal of the Korean Physical Society, 2016, 69 : 948 - 952