Bite Force Evaluation of Conventional Plating System Versus Locking Plating System for Mandibular Fracture

被引:9
|
作者
Giri K.Y. [1 ]
Sahu P. [1 ]
Rastogi S. [1 ]
Dandriyal R. [1 ]
Mall S. [1 ]
Singh A.P. [1 ]
Indra B N.P. [1 ]
Pratap Singh H. [1 ]
机构
[1] Department of Oral and Maxillofacial Surgery, Institute of Dental Sciences, Bareilly, U.P.
关键词
Bite force; Bite meter; Locking plates; Non-locking plates;
D O I
10.1007/s12663-015-0764-7
中图分类号
学科分类号
摘要
Aims and Objectives: To compare and evaluate the variation in recorded bite forces in patients with mandibular fractures undergoing open reduction and rigid internal fixation using standard 2.0 versus 2.0 mm locking miniplates. Materials and Methods: A prospective randomized study was conducted for the treatment of mandibular fractures. Twenty adult patients with 31 mandibular fractures requiring an open reduction and internal fixation were included in the study. The sample was divided into two groups depending upon whether the patients received 2.0 mm non-locking (standard) or 2.0 mm locking miniplates for rigid fixation respectively. Bite force was evaluated at 1st, 3rd and 6th week after the open reduction and rigid fixation using miniplates. Results: A statistically significant difference was not found in the clinical parameters such as pain, swelling, infection, paresthesia, hardware failure, and mobility between the fracture segments. The results showed that amongst locking vs non-locking miniplates, the former showed a greater bite force enhancement when compared to baseline values(post-trauma).A comparison between 2nd day post-operative vs 6th week post-operative values showed a significant increase in bite force in Group 1 (non-locking) (p < 0.05) whereas the values Were highly significant (p < 0.001) in Group 2 (locking Plate). Conclusion: The findings were suggestive that the efficacy of locking miniplates plate in mandibular fracture was superior in terms of bearing the masticatory loads during osteosynthesis of the fracture. However, the clinical results were almost similar to those seen with non-locking miniplate osteosynthesis. © 2015, The Association of Oral and Maxillofacial Surgeons of India.
引用
收藏
页码:972 / 978
页数:6
相关论文
共 50 条
  • [31] Parallel Plating of Simulated Distal Humerus Fractures Demonstrates Increased Stiffness Relative to Orthogonal Plating With a Distal Humerus Locking Plate System
    Taylor, Phillip A.
    Owen, John R.
    Benfield, Charles P.
    Wayne, Jennifer S.
    Boardman, N. Douglas, III
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (04) : E118 - E122
  • [32] Biomechanical testing of a novel, minimally invasive rib fracture plating system
    Sales, J. Rafe
    Ellis, Thomas J.
    Gillard, Joel
    Liu, Qi
    Chen, Joyce C.
    Ham, Bruce
    Mayberry, John C.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (05): : 1270 - 1274
  • [33] Biomechanical Evaluation of Clavicle Fracture Plating Techniques: Does a Locking Plate Provide Improved Stability? Erratum
    Celestre, P.
    Roberston, C.
    Mahar, A.
    Oka, R.
    Meunier, M.
    Schwartz, A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (04) : E95 - E95
  • [34] Volar Locking Plating of Extra-articular Distal Radius Fracture: A Retrospective Clinical Study Comparing Locking Screws versus Smooth Locking Pegs
    Tordjman, Daniel
    Younis, Mohammad
    Factor, Shai
    Eisenberg, Gilad
    Atlan, Franck
    McBeth, Jessica
    Pritsch, Tamir
    Rosenblatt, Yishai
    JOURNAL OF WRIST SURGERY, 2024, 13 (02) : 151 - 157
  • [35] Prospective Evaluation of Median Nerve Dysfunctions in Patients with a Distal Radius Fracture Treated with Volar Locking Plating
    Isobe, Fumihiro
    Yamazaki, Hiroshi
    Hayashi, Masanori
    Uchiyama, Shigeharu
    Miyaoka, Shunsuke
    Kato, Hiroyuki
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2019, 24 (04): : 392 - 399
  • [36] Plating technology ... System solution for bright nickel plating: Practical experience with a new adsorber system
    Gisske, Konrad
    Schrodter, Gerd
    Blittersdorf, Ralph
    MO Metalloberflache Beschichten von Metall und Kunststoff, 1999, 53 (07): : 23 - 25
  • [37] Double-locking precontoured plating system for malunited fractures of the distal end of humerus
    Tarallo L.
    Mugnai R.
    Rocchi M.
    Rovesta C.
    Catani F.
    MUSCULOSKELETAL SURGERY, 2016, 100 (Suppl 1) : 105 - 110
  • [38] Biomechanical evaluation of the percutaneous compression plating system for hip fractures
    Gotfried, Y
    Cohen, B
    Rotem, A
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (09) : 644 - 650
  • [39] Biomechanical Evaluation of a New MatrixMandible Plating System on Cadaver Mandibles
    Gateno, Jaime
    Cookston, Christopher
    Hsu, Sam Sheng-Pin
    Stal, Drew N.
    Durrani, Salim K.
    Gold, Jonathan
    Ismaily, Sabir
    Alexander, Jerry W.
    Noble, Philip C.
    Xia, James J.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (11) : 1900 - 1914
  • [40] Evaluation of the Effect of Phototherapy in Patients with Mandibular Fracture on Mandibular Dynamics, Pain, Edema, and Bite Force: A Pilot Study
    Lauriti, Leandro
    de Cerqueira Luz, Joao Gualberto
    Agnelli Mesquita-Ferrari, Raquel
    Santos Fernandes, Kristianne Porta
    Deana, Alessandro Melo
    Ratto Tempestini Horliana, Anna Carolina
    Costa-Santos, Larissa
    Brugnera Junior, Aldo
    Bussadori, Sandra Kalil
    PHOTOMEDICINE AND LASER SURGERY, 2018, 36 (01) : 24 - 30