Bite Force Evaluation of Conventional Plating System Versus Locking Plating System for Mandibular Fracture

被引:9
|
作者
Giri K.Y. [1 ]
Sahu P. [1 ]
Rastogi S. [1 ]
Dandriyal R. [1 ]
Mall S. [1 ]
Singh A.P. [1 ]
Indra B N.P. [1 ]
Pratap Singh H. [1 ]
机构
[1] Department of Oral and Maxillofacial Surgery, Institute of Dental Sciences, Bareilly, U.P.
关键词
Bite force; Bite meter; Locking plates; Non-locking plates;
D O I
10.1007/s12663-015-0764-7
中图分类号
学科分类号
摘要
Aims and Objectives: To compare and evaluate the variation in recorded bite forces in patients with mandibular fractures undergoing open reduction and rigid internal fixation using standard 2.0 versus 2.0 mm locking miniplates. Materials and Methods: A prospective randomized study was conducted for the treatment of mandibular fractures. Twenty adult patients with 31 mandibular fractures requiring an open reduction and internal fixation were included in the study. The sample was divided into two groups depending upon whether the patients received 2.0 mm non-locking (standard) or 2.0 mm locking miniplates for rigid fixation respectively. Bite force was evaluated at 1st, 3rd and 6th week after the open reduction and rigid fixation using miniplates. Results: A statistically significant difference was not found in the clinical parameters such as pain, swelling, infection, paresthesia, hardware failure, and mobility between the fracture segments. The results showed that amongst locking vs non-locking miniplates, the former showed a greater bite force enhancement when compared to baseline values(post-trauma).A comparison between 2nd day post-operative vs 6th week post-operative values showed a significant increase in bite force in Group 1 (non-locking) (p < 0.05) whereas the values Were highly significant (p < 0.001) in Group 2 (locking Plate). Conclusion: The findings were suggestive that the efficacy of locking miniplates plate in mandibular fracture was superior in terms of bearing the masticatory loads during osteosynthesis of the fracture. However, the clinical results were almost similar to those seen with non-locking miniplate osteosynthesis. © 2015, The Association of Oral and Maxillofacial Surgeons of India.
引用
收藏
页码:972 / 978
页数:6
相关论文
共 50 条
  • [21] PROSPECTIVE STUDY OF MANAGEMENT OF FRACTURE SHAFT OF HUMERUS WITH LOCKING COMPRESSION PLATING
    Wahed, Mohammed Abdul
    Prasad, P. N.
    Reddy, Nishith
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (34): : 1950 - 1953
  • [22] Supracutaneous plating using a locking plate for the treatment of a tibial fracture in a cat
    Nicetto, Tommaso
    Longo, Federico
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2017, 58 (06): : 585 - 590
  • [23] Volar locking compression plating versus dorsal plating for fractures of the distal radius. A prospective, randomized study
    Zettl, R. P.
    Clauberg, E.
    Nast-Kolb, D.
    Ruchholtz, S.
    Kuehne, C. A.
    UNFALLCHIRURG, 2009, 112 (08): : 712 - +
  • [24] Comparison of Bite Force with Locking Plates versus Non-Locking Plates in the Treatment of Mandibular Fractures: A Meta-Analysis
    Ramos Gloria, Jose Cristiano
    Fernandes, Ighor Andrade
    da Silveira, Esmeralda Maria
    de Souza, Glaciele Maria
    Rocha, Ricardo Lopes
    Galvao, Endi Lanza
    Moreira Falci, Saulo Gabriel
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2018, 22 (02) : 181 - 189
  • [25] Assessment of Bite Force in Patients Treated with 2.0-mm Traditional Miniplates versus 2.0-mm Locking Plates for Mandibular Fracture
    Rastogi, Sanjay
    Reddy, Mahendra Parvath
    Swarup, Azeez Gaurav
    Swarup, Divya
    Choudhury, Rupshikha
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2016, 9 (01) : 62 - 68
  • [26] Evaluation of condylar neck fracture plating techniques
    Choi, BH
    Kim, KN
    Kim, HJ
    Kim, MK
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1999, 27 (02) : 109 - 112
  • [27] AUTOMATED CHROMIUM PLATING SYSTEM
    不详
    MACHINERY AND PRODUCTION ENGINEERING, 1970, 116 (2987): : 232 - &
  • [28] SAVE ON PLATING WASTE SYSTEM
    GALLO, BR
    CULLOTA, JM
    WATER & WASTES ENGINEERING, 1972, 9 (01): : A18 - &
  • [29] SPUTTER ION PLATING SYSTEM
    WYMAN, V
    ENGINEERING DIGEST, 1985, 31 (03): : 24 - 24
  • [30] Biomechanical testing of a novel, minimally invasive rib fracture plating system
    Ellis, T
    Gillard, J
    Sales, JR
    Liu, Q
    Chen, J
    Ham, B
    Mayberry, J
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2005, 201 (03) : S50 - S50