Atlantoaxial fusion using anterior transarticular screw fixation of C1–C2: technical innovation and biomechanical study

被引:0
|
作者
Milan K. Sen
Thomas Steffen
Lorne Beckman
Anthony Tsantrizos
Rudolph Reindl
Max Aebi
机构
[1] McGill University Health Centre,Division of Orthopaedic Surgery
[2] Royal Victoria Hospital,McGill Orthopaedic Research Laboratory
[3] 370 East 69th Street,undefined
[4] Apt. 6E,undefined
来源
European Spine Journal | 2005年 / 14卷
关键词
Atlas; Axis; Fracture; Spinal instability; Transarticular fixation;
D O I
暂无
中图分类号
学科分类号
摘要
This study is an attempt to describe a new technique for anterior transarticular screw fixation of the atlantoaxial joints, and to compare the stability of this construct to posterior transarticular screw fixation with and without laminar cerclage wiring. Nine human cadaveric specimens were included in this study. The C1–C2 motion segment was instrumented using either anterior transarticular screws (group 1), posterior transarticular screws alone (group 2), or posterior screws with interlaminar cerclage wires (group 3). Using an unconstrained mechanical testing machine, the specimens were tested in rotation, lateral bending, and flexion-extension using nondestructive loads of ±2 N m. The specimens were also tested in translation using nondestructive loads of ±100 N. All values for the three groups with regards to anterior-posterior displacement, rotation, and lateral bending were similar as determined using a Kruskal–Wallis rank sum test with a significance level of p<0.05. The only significant difference was registered in flexion-extension where the cerclage wire added some strength to the construct. Anterior transarticular screw fixation of the atlantoaxial spine has several advantages over posterior fixation techniques, and is as stable as posterior transarticular fixation in all clinically significant planes of motion. The addition of posterior interlaminar cerclage wiring further improves resistance to flexion-extension forces. Anterior transarticular screw fixation of the atlantoaxial joint is a useful technique for achieving C1–C2 stabilization.
引用
收藏
页码:512 / 518
页数:6
相关论文
共 50 条
  • [41] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis - Reply
    Dickman, CA
    Sonntag, VKH
    NEUROSURGERY, 1999, 44 (03) : 688 - 689
  • [42] Atlantoaxial arthrodesis using C1-C2 transarticular screw fixation in a case of Morquio syndrome
    Kulkarni, Arvind G.
    Shah, Siddharth M.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (05) : 470 - 472
  • [43] Posterior spinal fusion using a unilateral C1 posterior arch screw and a C2 laminar screw for atlantoaxial fracture dislocation
    Ono, Yuichi
    Miyakoshi, Naohisa
    Hongo, Michio
    Kasukawa, Yuji
    Ishikawa, Yoshinori
    Kudo, Daisuke
    Kimura, Ryota
    Iida, Jumpei
    Shimada, Yoichi
    SAGE OPEN MEDICAL CASE REPORTS, 2019, 7
  • [44] Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation
    Lee, Sun-Ho
    Kim, Eun Sang
    Sung, Joo-Kyung
    Park, Yeun-Mook
    Eoh, Whan
    JOURNAL OF CLINICAL NEUROSCIENCE, 2010, 17 (07) : 886 - 892
  • [45] Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture
    Wu, Ai-Min
    Jin, Hai-Ming
    Lin, Zhong-Ke
    Chi, Yong-Long
    Wang, Xiang-Yang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [46] Atlantoaxial Fusion Using C1 Sublaminar Cables and C2 Translaminar Screws
    Larsen, Alexandra M. Giantini
    Grannan, Benjamin L.
    Koffie, Robert M.
    Coumans, Jean-Valery
    OPERATIVE NEUROSURGERY, 2018, 14 (06) : 647 - 653
  • [47] Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture
    Ai-Min Wu
    Hai-Ming Jin
    Zhong-Ke Lin
    Yong-Long Chi
    Xiang-Yang Wang
    Journal of Orthopaedic Surgery and Research, 12
  • [48] Posterior C1–C2 screw and rod instrument for reduction and fixation of basilar invagination with atlantoaxial dislocation
    Sheng Li Guo
    Ding Biao Zhou
    Xin Guang Yu
    Yi Heng Yin
    Guang Yu Qiao
    European Spine Journal, 2014, 23 : 1666 - 1672
  • [49] Isocentric C-arm three-dimensional navigation versus conventional C-arm assisted C1–C2 transarticular screw fixation for atlantoaxial instability
    Yongliang Yang
    Fu Wang
    Shumei Han
    Yonghui Wang
    Jinlei Dong
    Lianxin Li
    Dongsheng Zhou
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 1083 - 1092
  • [50] Odontoid fractures in combination with C1 fractures in the elderly treated by combined anterior odontoid and transarticular C1/2 screw fixation
    Josten, Christoph
    Jarvers, Jan-Sven
    Glasmacher, Stefan
    Spiegl, Ulrich J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (11) : 1525 - 1531