This study is an attempt to describe a new technique for anterior transarticular screw fixation of the atlantoaxial joints, and to compare the stability of this construct to posterior transarticular screw fixation with and without laminar cerclage wiring. Nine human cadaveric specimens were included in this study. The C1–C2 motion segment was instrumented using either anterior transarticular screws (group 1), posterior transarticular screws alone (group 2), or posterior screws with interlaminar cerclage wires (group 3). Using an unconstrained mechanical testing machine, the specimens were tested in rotation, lateral bending, and flexion-extension using nondestructive loads of ±2 N m. The specimens were also tested in translation using nondestructive loads of ±100 N. All values for the three groups with regards to anterior-posterior displacement, rotation, and lateral bending were similar as determined using a Kruskal–Wallis rank sum test with a significance level of p<0.05. The only significant difference was registered in flexion-extension where the cerclage wire added some strength to the construct. Anterior transarticular screw fixation of the atlantoaxial spine has several advantages over posterior fixation techniques, and is as stable as posterior transarticular fixation in all clinically significant planes of motion. The addition of posterior interlaminar cerclage wiring further improves resistance to flexion-extension forces. Anterior transarticular screw fixation of the atlantoaxial joint is a useful technique for achieving C1–C2 stabilization.
引用
收藏
页码:512 / 518
页数:6
相关论文
共 50 条
  • [31] Posterior C1 lateral mass and C2 pedicle screw internal fixation for atlantoaxial instability
    Xie, Yang
    Li, Zhonghai
    Tang, Hao
    Li, Ming
    Guan, Zhengmao
    JOURNAL OF CLINICAL NEUROSCIENCE, 2009, 16 (12) : 1592 - 1594
  • [32] Biomechanical evaluation of two alternative techniques to the Goel-Harms technique for atlantoaxial fixation: C1 lateral mass-C2 bicortical translaminar screw fixation and C1 lateral mass-C2/3 transarticular screw fixation
    Du, Yue-Qi
    Li, Teng
    Ma, Chao
    Qiao, Guang-Yu
    Yin, Yi-Heng
    Yu, Xin-Guang
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 32 (05) : 682 - 688
  • [33] C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury
    Guo, Qunfeng
    Liu, Jun
    Ni, Bin
    Lu, Xuhua
    Zhou, Fengjin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1207 - 1210
  • [34] C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury
    Qunfeng Guo
    Jun Liu
    Bin Ni
    Xuhua Lu
    Fengjin Zhou
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 1207 - 1210
  • [35] Atlantoaxial joint fusion using anterior transarticular screw fixation and bone grafting for atlantoaxial joint instability
    王文军
    China Medical Abstracts(Surgery), 2011, 20 (02) : 85 - 85
  • [36] Endovascular Treatment of a Vertebral Artery Pseudoaneurysm Following Posterior C1–C2 Transarticular Screw Fixation
    Jose C. Méndez
    Francisco González-Llanos
    CardioVascular and Interventional Radiology, 2005, 28 : 107 - 109
  • [37] C1-c2 transarticular screw fixation: Technical aspects
    Haid, RW
    NEUROSURGERY, 2001, 49 (01) : 71 - 74
  • [38] Biomechanical comparison of two new atlantoaxial fixation techniques with C1-2 transarticular screw-graft fixation
    Hartl, Roger
    Chamberlain, Robert H.
    Fifield, Mary S.
    Chou, Dean
    Sonntag, Volker K. H.
    Crawford, Neil R.
    JOURNAL OF NEUROSURGERY-SPINE, 2006, 5 (04) : 336 - 342
  • [39] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis - Comment
    McCormick, PC
    NEUROSURGERY, 1998, 43 (02) : 280 - 280
  • [40] Atlantoaxial arthrodesis using C1-C2 transarticular screw fixation in a case of Morquio syndrome
    Arvind G. Kulkarni
    Siddharth M. Shah