Application of a pelvic phantom in brachytherapy dosimetry for high-dose-rate (HDR) 192Ir source based on Monte Carlo simulations

被引:0
|
作者
Woo Sang Ahn
Wonsik Choi
Seong Soo Shin
Jinhong Jung
机构
[1] Gangneung Asan Hospital,Department of Radiation Oncology
[2] Kyung Hee University Medical Center,Department of Radiation Oncology
来源
关键词
Brachytherapy; Dosimetry; Ir; MCNPX; Radial dose function; 87.53.Jw;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, we evaluate how the radial dose function is influenced by the source position as well as the phantom size and shape. A pelvic water phantom similar to the pelvic shape of a human body was designed by averaging dimensions obtained from computed tomography (CT) images of patients treated with brachytherapy for cervical cancer. Furthermore, for the study of the effects of source position on the dose distribution, the position of the source in the water phantom was determined by using the center of mass of the gross target volume (GTV) in the CT images. To obtain the dosimetric parameter of a high-dose-rate (HDR) 192Ir source, we performed Monte Carlo simulations by using the Monte Carlo n-particle extended code (MCNPX). The radial dose functions obtained using the pelvic water phantom were compared with those of spherical phantom with different sizes, including the Monte Carlo (MC) results of Williamson and Li. Differences between the radial dose functions from this study and the data in the literature increased with the radial distances. The largest differences appeared for spherical phantom with the smallest size. In contrast to the published MC results, the radial dose function of the pelvic water phantom significantly decreased with radial distance in the vertical direction because full scattering was not possible. When the source was located in posterior position 2 cm from the center in the pelvic water phantom, the differences between the radial dose functions rapidly decreased with the radial distance in the lower vertical direction. If the International Commission on Radiation Units and Measurements bladder and rectum points are considered, doses to these reference points could be underestimated by up to 1%–2% at a distance of 3 to 6 cm. Our simulation results provide a valid clinical reference data and can used to improve the accuracy of the doses delivered during brachytherapy applied to patients with cervical cancer.
引用
收藏
页码:557 / 564
页数:7
相关论文
共 50 条
  • [1] Application of a pelvic phantom in brachytherapy dosimetry for high-dose-rate (HDR) 192Ir source based on Monte Carlo simulations
    Ahn, Woo Sang
    Choi, Wonsik
    Shin, Seong Soo
    Jung, Jinhong
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (04) : 557 - 564
  • [2] Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Karaiskos, P
    Sandilos, P
    [J]. MEDICAL PHYSICS, 2000, 27 (11) : 2521 - 2527
  • [3] Erratum to: Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Akbar Sarabiasl
    Navid Ayoobian
    Hossein Poorbaygi
    Iraj Jabbari
    Mohammad Reza Javanshir
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 591 - 591
  • [4] Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Sakelliou, L
    Sandilos, P
    Antypas, C
    Vlachos, L
    Koutsouveli, E
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 1975 - 1984
  • [5] Monte Carlo dosimetry of a new 192Ir pulsed dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Pantelis, E
    Papagiannis, P
    Sakelliou, L
    Kouwenhoven, E
    Baltas, D
    [J]. MEDICAL PHYSICS, 2003, 30 (01) : 9 - 16
  • [6] Monte Carlo dosimetry of the Buchler high dose rate 192Ir source
    Ballester, F
    Pérez-Calatayud, J
    Puchades, V
    Lluch, JL
    Serrano-Andrés, MA
    Limami, Y
    Lliso, F
    Casal, E
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03): : N79 - N90
  • [7] Monte Carlo dosimetry of the VariSource high dose rate 192Ir source
    Wang, RQ
    Sloboda, RS
    [J]. MEDICAL PHYSICS, 1998, 25 (04) : 415 - 423
  • [8] High-Dose-Rate 192Ir Brachytherapy Dose Verification: A Phantom Study
    Nikoofar, Alireza
    Hoseinpour, Zohreh
    Mahdavi, Seied Rabi
    Hasanzadeh, Hadi
    Tavirani, Mostafa Rezaei
    [J]. IRANIAN JOURNAL OF CANCER PREVENTION, 2015, 8 (03)
  • [9] Monte Carlo angular dose distribution of the microselectron HDR 192Ir brachytherapy source
    Wallace, S.
    Wong, T.
    Fernando, W.
    [J]. Australasian Physical and Engineering Sciences in Medicine, 1999, 22 (01): : 1 - 7
  • [10] Monte Carlo and experimental high dose rate 192Ir brachytherapy dosimetry with microDiamond detectors
    Rossi, Giulio
    Gainey, Mark
    Thomann, Benedikt
    Kollefrath, Michael
    Wuerfel, Jan
    Allgaier, Bernd
    Baltas, Dimos
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (03): : 272 - 281