Monte Carlo dosimetry of the VariSource high dose rate 192Ir source

被引:34
|
作者
Wang, RQ [1 ]
Sloboda, RS [1 ]
机构
[1] Cross Canc Inst, Dept Med Phys, Edmonton, AB T6G 1Z2, Canada
关键词
brachytherapy dosimetry; high dose rate; Ir-192; source; Monte Carlo calculations;
D O I
10.1118/1.598216
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of the work is to calculate basic dosimetry data for a VariSource high dose rate Ir-192 source in water. These basic dosimetry data, expressed in the dose calculation formalism endorsed by the Interstitial Collaborative Working Group and AAPM Task group 43, include the dose rate constant, the radial dose function, and the anisotropy function. A modified version of the EGS4 Monte Carlo code was used to calculate (1) the transverse-axis dose distribution at radial distances from 0.1 to 14 cm, (2) the two-dimensional dose distribution for axial and radial distances from 0.1 cm to 10 cm, and (3) the air-kerma strength, for the VariSource high dose rate Ir-192 source. From these Monte Carlo results the basic dosimetry data were derived. The calculated dose rate constant for the high dose rate source is 1.044+/-0.2% cGy h(-1) per unit air-kerma strength. The anisotropy function exhibits 40%-60% deviations from isotropy at positions on the long axis. The radial dose function for the source is nearly identical to that for a microSelectron high dose rate Ir-192 source, except at radial distances smaller than 0.5 cm where values for VariSource are 1.7%-2.8% smaller. These basic dosimetry data were compared with corresponding results from other authors for high and low dose rate Ir-192 sources, as well as with Meisberger's fitting formula. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)01404-7].
引用
收藏
页码:415 / 423
页数:9
相关论文
共 50 条
  • [1] Monte Carlo dosimetry of the Buchler high dose rate 192Ir source
    Ballester, F
    Pérez-Calatayud, J
    Puchades, V
    Lluch, JL
    Serrano-Andrés, MA
    Limami, Y
    Lliso, F
    Casal, E
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03): : N79 - N90
  • [2] A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Sandilos, P
    Dardoufas, K
    Vlachos, L
    [J]. MEDICAL PHYSICS, 1999, 26 (08) : 1498 - 1502
  • [3] Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Sarabiasl, Akbar
    Ayoobian, Navid
    Jabbari, Iraj
    Poorbaygi, Hossein
    Javanshir, Mohammad Reza
    [J]. Australasian Physical and Engineering Sciences in Medicine, 2016, 39 (02): : 413 - 422
  • [4] Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Karaiskos, P
    Sandilos, P
    [J]. MEDICAL PHYSICS, 2000, 27 (11) : 2521 - 2527
  • [5] Erratum to: Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Akbar Sarabiasl
    Navid Ayoobian
    Hossein Poorbaygi
    Iraj Jabbari
    Mohammad Reza Javanshir
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 591 - 591
  • [6] Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Sakelliou, L
    Sandilos, P
    Antypas, C
    Vlachos, L
    Koutsouveli, E
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 1975 - 1984
  • [7] Monte Carlo dosimetry of a new 192Ir pulsed dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Pantelis, E
    Papagiannis, P
    Sakelliou, L
    Kouwenhoven, E
    Baltas, D
    [J]. MEDICAL PHYSICS, 2003, 30 (01) : 9 - 16
  • [8] Monte Carlo and experimental high dose rate 192Ir brachytherapy dosimetry with microDiamond detectors
    Rossi, Giulio
    Gainey, Mark
    Thomann, Benedikt
    Kollefrath, Michael
    Wuerfel, Jan
    Allgaier, Bernd
    Baltas, Dimos
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (03): : 272 - 281
  • [9] Experimental and Monte Carlo endovascular dosimetry of a 192Ir source
    Piermattei, A
    Fidanzio, A
    Azario, L
    Russo, A
    Perrone, F
    Toni, MP
    Capote, R
    [J]. PHYSICA MEDICA, 2003, 19 (02) : 111 - 118
  • [10] Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source (vol 39, pg 413, 2016)
    Sarabiasl, Akbar
    Ayoobian, Navid
    Poorbaygi, Hossein
    Jabbari, Iraj
    Javanshir, Mohammad Reza
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (02) : 591 - 591