CT evaluation prior to transapical aortic valve replacement: semi-automatic versus manual image segmentation

被引:0
|
作者
Borek Foldyna
Camelia Jungert
Christian Luecke
Konstantin von Aspern
Sonja Boehmer-Lasthaus
Eva Maria Rueth
Matthias Grothoff
Stefan Nitzsche
Matthias Gutberlet
Friedrich Wilhelm Mohr
Lukas Lehmkuhl
机构
[1] University of Leipzig – Heart Center,Department of Interventional and Diagnostic Radiology
[2] University of Leipzig – Heart Center,Department of Cardiac Surgery
[3] Siemens Healthcare – Imaging & Therapy,undefined
关键词
Transapical valve replacement; Aortic valve; Computed tomography; Data segmentation; Data evaluation; Experienced versus inexperienced users; Efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
To compare the performance of semi-automatic versus manual segmentation for ECG-triggered cardiovascular computed tomography (CT) examinations prior to transcatheter aortic valve replacement (TAVR), with focus on the speed and precision of experienced versus inexperienced observers. The preoperative ECG-triggered CT data of 30 consecutive patients who were scheduled for TAVR were included. All datasets were separately evaluated by two radiologists with 1 and 5 years of experience (novice and expert, respectively) in cardiovascular CT using an evaluation software program with or without a semi-automatic TAVR workflow. The time expended for data loading and all segmentation steps required for the implantation planning were assessed. Inter-software as well as inter-observer reliability analysis was performed. The CT datasets were successfully evaluated, with mean duration between 520.4 ± 117.6 s and 693.2 ± 159.5 s. The three most time-consuming steps were the 3D volume rendering, the measurement of aorta diameter and the sizing of the aortic annulus. Using semi-automatic segmentation, a novice could evaluate CT data approximately 12.3 % faster than with manual segmentation, and an expert could evaluate CT data approximately 10.3 % faster [mean differences of 85.4 ± 83.8 s (p < 0.001) and 59.8 ± 101 s (p < 0.001), respectively]. The inter-software reliability for a novice was slightly lower than for an expert; however, the reliability for a novice and expert was excellent (ICC 0.92, 95 % CI 0.75–0.97/ICC 0.96, 95 % CI 0.91–0.98). Automatic aortic annulus detection failed in two patients (6.7 %). The study revealed excellent inter-software and inter-observer reliability, with a mean ICC of 0.95. TAVR evaluation can be accomplished significantly faster with semi-automatic rather than with manual segmentation, with comparable exactness, showing a benefit for experienced and inexperienced observers.
引用
收藏
页码:1233 / 1242
页数:9
相关论文
共 50 条
  • [31] Production and maintenance performance analysis: manual versus semi-automatic LHDs
    Gustafson, Anna
    Schunnesson, Hakan
    Galar, Diego
    Kumar, Uday
    JOURNAL OF QUALITY IN MAINTENANCE ENGINEERING, 2013, 19 (01) : 74 - +
  • [32] Redo Surgical Aortic Valve Replacement After Prior Transcatheter Versus Surgical Aortic Valve Replacement
    Hawkins, Robert B.
    Deeb, G. Michael
    Sukul, Devraj
    Patel, Himanshu J.
    Gualano, Sarah K.
    Chetcuti, Stanley J.
    Grossman, P. Michael
    Ailawadi, Gorav
    Fukuhara, Shinichi
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (08) : 942 - 953
  • [33] Comparison of Manual Vs. Semi-Automatic CBCT Image Analysis
    Claps, L.
    Alaei, P.
    MEDICAL PHYSICS, 2019, 46 (06) : E556 - E556
  • [34] Myocardial Injury After Transaortic Versus Transapical Transcatheter Aortic Valve Replacement
    Ribeiro, Henrique B.
    Dahou, Abdellaziz
    Urena, Marina
    Carrasco, Jose Luis
    Mohammadi, Siamak
    Doyle, Daniel
    Le Ven, Florent
    Allende, Ricardo
    Amat-Santos, Ignacio
    Paradis, Jean-Michel
    DeLarochelliere, Robert
    Puri, Rishi
    Altisent, Omar Abdul-Jawad
    del Trigo, Maria
    Campelo-Parada, Francisco
    Pibarot, Philippe
    Dumont, Eric
    Rodes-Cabau, Josep
    ANNALS OF THORACIC SURGERY, 2015, 99 (06): : 2001 - 2009
  • [35] Myocardial Injury Following Transaortic Versus Transapical Transcatheter Aortic Valve Replacement
    Ribeiro, Henrique B.
    Dahou, Abdellaziz
    Urena, Marina
    Mohammadi, Siamak
    Doyle, Daniel
    Allende, Ricardo
    Amat-Santos, Ignacio J.
    Paradis, Jean-Michel
    DeLarochelliere, Robert
    Puri, Rishi
    Altisent, Omar Abdul-Jawad
    Del Trigo, Maria
    Campelo-Parada, Francisco
    Pibarot, Philippe
    Dumont, Eric
    Rodes-Cabau, Josep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B264 - B264
  • [36] Semi-automatic segmentation of speech: Manual segmentation strategy. Problem space analysis.
    Szymanski, M
    Grocholewski, S
    Computer Recognition Systems, Proceedings, 2005, : 747 - 755
  • [37] Semi-automated versus Manual Aortic Annulus Analysis for Planning of Transcatheter Aortic Valve Replacement (TAVR/TAVI)
    Lou, Junyang
    Obuchowski, Nancy A.
    Krishnaswamy, Amar
    Popovic, Zoran
    Flamm, Scott D.
    Bolen, Michael
    Desai, Milind
    Kapadia, Samir R.
    Svensson, Lars G.
    Tuzcu, E. M.
    Schoenhagen, Paul
    CIRCULATION, 2013, 128 (22)
  • [38] A Semi-Automatic Cardiac Substructure Segmentation Platform for Radiotherapy Planning CT
    Zhang, E.
    Li, J.
    Timmerman, R.
    Alluri, P.
    Chen, M.
    Lu, W.
    Gu, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E511 - E511
  • [39] Texture-driven parametric snakes for semi-automatic image segmentation
    Badoual, Anais
    Unser, Michael
    Depeursinge, Adrien
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2019, 188
  • [40] Adaptive mesh image segmentation for semi-automatic video object extraction
    Hu, Rong
    Chen, Jian
    Shu Ju Cai Ji Yu Chu Li/Journal of Data Acquisition and Processing, 2001, 16 (04): : 469 - 472