Calcium phosphate cement augmentation after volar locking plating of distal radius fracture significantly increases stability

被引:11
|
作者
Kainz H. [1 ]
Dall'Ara E. [2 ]
Antoni A. [1 ]
Redl H. [1 ]
Zysset P. [2 ]
Weninger P. [1 ]
机构
[1] Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Donaueschingenstraße 13
[2] Institute of Lightweight Design and Structural Biomechanics, Vienna University of Technology, Vienna
关键词
Biomaterial; Biomechanics; Distal radius fracture; Fracture fixation; Volar plating;
D O I
10.1007/s00590-013-1285-z
中图分类号
学科分类号
摘要
Purpose: Distal radius fractures represent the most common fractures in adults. Volar locking plating to correct unstable fractures has become increasingly popular. Although reasonable primary reduction is possible in most cases, maintenance of reduction until the fracture is healed is often problematic in osteoporotic bone. To our knowledge, no biomechanical studies have compared the effect of enhancement with biomaterial on two different volar fixed-angle plates. Methods: Human fresh-frozen cadaver pairs of radii were used to simulate an AO/OTA 23-A3 fracture. In a total of four groups (n = 7 for each group), two volar fixed-angle plates (Aptus 2.5 mm locking fracture plate, Medartis, Switzerland and VA-LCP two-column distal radius plate 2.4, volar, Synthes, Switzerland) with or without an additional injection of a biomaterial (Hydroset Injectable HA Bone Substitute, Stryker, Switzerland) into the dorsal comminution zone were used to fix the distal metaphyseal fragment. Each specimen was tested load-controlled under cyclic loading with a servo-hydraulic material testing machine. Displacement, stiffness, dissipated work and failure mode were recorded. Results: Improved mechanical properties (decreased displacement, increased stiffness, decreased dissipated work) were found in both plates if the biomaterial was additionally injected. Improvement of mechanical parameters after biomaterial injection was more evident in the Synthes plate compared to the Aptus plate. Pushing out of the screws was noticed as a failure mode only in samples lacking supplementary biomaterial. Conclusions: Injection of a biomaterial into the dorsal comminution zone increases stability after volar locking plating of distal radius fractures in vitro. © 2013 Springer-Verlag.
引用
收藏
页码:869 / 875
页数:6
相关论文
共 50 条
  • [1] Isokinetic evaluation of pronation after volar plating of a distal radius fracture
    Huh, Jung Kyu
    Lim, Jae-Young
    Song, Cheol Ho
    Baek, Goo Hyun
    Lee, Young Ho
    Gong, Hyun Sik
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (02): : 200 - 204
  • [2] Pearls and Pitfalls of the Volar Locking Plating for Distal Radius Fractures
    Im, Jin-Hyung
    Lee, Joo-Yup
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (02): : 125 - 132
  • [3] Results of volar locking plating for unstable distal radius fractures
    Sugun, Tahir Sadik
    Gurbuz, Yusuf
    Ozaksar, Kemal
    Toros, Tulgar
    Kayalar, Murat
    Bal, Emin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2012, 46 (01) : 22 - 25
  • [4] VOLAR PLATING OF DISTAL RADIUS FRACTURE: A RETROSPECTIVE ANALYSIS
    Moirangthem, Victor
    Kumar, Bharat R. J.
    Vijayanand, R. R.
    Reddy, Narayana M.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (52): : 9094 - 9102
  • [5] Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report
    Shinohara, Takaaki
    Hirata, Hitoshi
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2017, 79 (04): : 551 - 557
  • [6] A systematic review of volar locking plate removal after distal radius fracture
    Yamamoto, Michiro
    Fujihara, Yuki
    Fujihara, Nasa
    Hirata, Hitoshi
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (12): : 2650 - 2656
  • [7] Breakage of a volar locking plate after delayed union of a distal radius fracture
    De Baere, Tom
    Lecouvet, Frederic
    Barbier, Olivier
    ACTA ORTHOPAEDICA BELGICA, 2007, 73 (06): : 785 - 790
  • [8] Impact of surgeon volume on the risk of complications following volar locking plating of unstable distal radius fracture
    Liang, Zhiquan
    Zhang, Wenhao
    Deng, Yingjie
    Guo, Hao
    Li, Leijiang
    Xiang, Wenyuan
    Fang, Rui
    MEDICINE, 2024, 103 (48)
  • [9] Prospective Evaluation of Median Nerve Dysfunctions in Patients with a Distal Radius Fracture Treated with Volar Locking Plating
    Isobe, Fumihiro
    Yamazaki, Hiroshi
    Hayashi, Masanori
    Uchiyama, Shigeharu
    Miyaoka, Shunsuke
    Kato, Hiroyuki
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2019, 24 (04): : 392 - 399
  • [10] Complications After Volar Plating of Distal Radius Fractures