Flow injection analysis of trace chromium (VI) in drinking water with a liquid waveguide capillary cell and spectrophotometric detection

被引:0
|
作者
Jian Ma
Dongxing Yuan
Robert H. Byrne
机构
[1] Xiamen University,State Key Laboratory of Marine Environmental Science, College of Environment and Ecology
[2] University of South Florida,College of Marine Science
来源
关键词
Liquid waveguide capillary cell; Flow injection analysis; Nanomolar detection limit; Chromium (VI); Drinking water; Spectrophotometry;
D O I
暂无
中图分类号
学科分类号
摘要
Hexavalent chromium (Cr(VI)) is an acknowledged hazardous material in drinking waters. As such, effective monitoring and assessment of the risks posed by Cr(VI) are important analytical objectives for both human health and environmental science. However, because of the lack of highly sensitive, rapid, and simple procedures, a relatively limited number of studies have been carried out in this field. Here we report a simple and sensitive analytical procedure of flow injection analysis (FIA) for sub-nanomolar Cr(VI) in drinking water samples with a liquid core waveguide capillary cell (LWCC). The procedure is based on a highly selective reaction between 1, 5-diphenylcarbazide and Cr(VI) under acidic conditions. The optimized experimental parameters included reagent concentrations, injection volume, length of mixing coil, and flow rate. Measurements at 540 nm, and a 650-nm reference wavelength, produced a 0.12-nM detection limit. Relative standard deviations for 1, 2, and 10 nM samples were 5.6, 3.6, and 0.72 % (n = 9), and the analysis time was <2 min sample−1. The effects of salinity and interfering ions, especially Fe(III), were evaluated. Using the FIA-LWCC method, different sources of bottled waters and tap waters were examined. The Cr(VI) concentrations of the bottled waters ranged from the detection limit to ∼20 nM, and tap waters collected from the same community supply had Cr(VI) concentration around 14 nM.
引用
收藏
页码:367 / 373
页数:6
相关论文
共 50 条
  • [21] Determination of trace chromium (VI) ion in chrome tanning agents by flow injection analysis
    Zhang, XS
    Jiang, XP
    Liu, MH
    Den, Y
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2000, 84 (06): : 255 - 257
  • [22] Determination of trace chromium (VI) ion in chrome tanning agents by flow injection analysis
    Zhang, Xinshen
    Jiang, Xiaoping
    Liu, Minghua
    Den, Yun
    Journal of the Society of Leather Technologies and Chemists, 2000, 84 (06): : 255 - 257
  • [23] A shipboard method for catalytic kinetic spectrophotometric determination of trace Cu(II) concentrations in seawater using reverse flow injection analysis coupled with a long path length liquid waveguide capillary cell
    Wang, Ting
    Huang, Yongming
    Zhu, Yong
    Xu, Jin
    Li, Dewang
    Wang, Bin
    Guo, Weidong
    Yuan, Dongxing
    MICROCHEMICAL JOURNAL, 2022, 179
  • [24] Spectrophotometric determination of zinc and copper in a multi-syringe flow injection analysis system using a liquid waveguide capillary cell: Application to natural waters
    Pascoa, Ricardo N. M. J.
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    TALANTA, 2011, 84 (05) : 1267 - 1272
  • [25] A catalytic spectrophotometric method for determination of nanomolar manganese in seawater using reverse flow injection analysis and a long path length liquid waveguide capillary cell
    Feng, Sichao
    Yuan, Dongxing
    Huang, Yongming
    Lin, Kunning
    Zhu, Yong
    Ma, Jian
    TALANTA, 2018, 178 : 577 - 582
  • [26] FLOW-INJECTION ANALYSIS FOR TRACE ALUMINUM WITH ONLINE PRECONCENTRATION AND SPECTROPHOTOMETRIC DETECTION
    KOBAYASHI, J
    BABA, M
    MIYAZAKI, M
    ANALYTICAL SCIENCES, 1994, 10 (02) : 287 - 291
  • [27] Titanium determination by multisyringe flow injection analysis system and a liquid waveguide capillary cell in solid and liquid environmental samples
    Sanchez-Quiles, David
    Tovar-Sanchez, Antonio
    Horstkotte, Burkhard
    MARINE POLLUTION BULLETIN, 2013, 76 (1-2) : 89 - 94
  • [28] Spectrophotometric flow system using vanadomolybdophosphate detection chemistry and a liquid waveguide capillary cell for the determination of phosphate with improved sensitivity in surface and ground water samples
    Neves, M. Sofia A. C.
    Souto, M. Renata S.
    Toth, Ildiko V.
    Victal, Sergio M. A.
    Drumond, M. Claudia
    Rangel, Antonio O. S. S.
    TALANTA, 2008, 77 (02) : 527 - 532
  • [29] Reversed Flow Injection Analysis of Nitrate in Drinking Water with UV-induced Reduction to Nitrite and Spectrophotometric Detection
    Zhang Min
    Yuan Dong-Xing
    Feng Si-Chao
    Huang Yong-Ming
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (06) : 943 - 944
  • [30] A modified method for on-line determination of trace ammonium in seawater with a long-path liquid waveguide capillary cell and spectrophotometric detection
    Zhu, Yong
    Yuan, Dongxing
    Huang, Yongming
    Ma, Jian
    Feng, Sichao
    Lin, Kunning
    MARINE CHEMISTRY, 2014, 162 : 114 - 121