A catalytic spectrophotometric method for determination of nanomolar manganese in seawater using reverse flow injection analysis and a long path length liquid waveguide capillary cell

被引:13
|
作者
Feng, Sichao [1 ]
Yuan, Dongxing [1 ]
Huang, Yongming [1 ]
Lin, Kunning [1 ]
Zhu, Yong [2 ]
Ma, Jian [1 ]
机构
[1] Xiamen Univ, State Key Lab Marine Environm Sci, Coll Environm & Ecol, Xiamen 361102, Peoples R China
[2] State Ocean Adm, Inst Oceanog 2, Hangzhou 310032, Zhejiang, Peoples R China
关键词
Nanomolar manganese; Seawater; Catalytic spectrophotometric detection; Reverse flow injection analysis; Liquid waveguide capillary cell; TRACE DISSOLVED MANGANESE; SOLID-PHASE EXTRACTION; COASTAL WATERS; ONLINE PRECONCENTRATION; REDOX SPECIATION; ATLANTIC-OCEAN; IRON; ESTUARINE; SITU; SEA;
D O I
10.1016/j.talanta.2017.09.073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and precise method for determination of nanomolar manganese in seawater was developed, using reverse flow injection analysis, a long path length liquid waveguide capillary cell, and spectrophotometric detection. The reaction was based on manganese catalyzed oxidation of leucomalachite green with sodium periodate. Various experimental parameters were investigated and optimized. Foreign trace metal ions of iron, copper, zinc, nickel and aluminum did not cause obvious interference with manganese detection. Low manganese seawater was prepared and used as the blank and standards' matrix, to eliminate the seawater matrix effect. The method detection limit was 0.20 nmol L-1, and the quantification range was 0.50-10.00 nmol L-1, which should be sensitive enough and suitable for open ocean seawater analysis. The seawater certified reference material NASS-6 was used to test the accuracy, and good agreement was obtained. The proposed method was applied to analyze seawater samples collected at the SEATS station in the South China Sea. The vertical profile of the total dissolvable manganese is reported and discussed.
引用
收藏
页码:577 / 582
页数:6
相关论文
共 50 条
  • [1] Reverse flow injection analysis of nanomolar soluble reactive phosphorus in seawater with a long path length liquid waveguide capillary cell and spectrophotometric detection
    Ma, Jian
    Yuan, Dongxing
    Zhang, Min
    Liang, Ying
    TALANTA, 2009, 78 (01) : 315 - 320
  • [2] Simultaneous determination of nanomolar nitrite and nitrate in seawater using reverse flow injection analysis coupled with a long path length liquid waveguide capillary cell
    Feng, Sichao
    Zhang, Min
    Huang, Yongming
    Yuan, Dongxing
    Zhu, Yong
    TALANTA, 2013, 117 : 456 - 462
  • [3] A shipboard method for catalytic kinetic spectrophotometric determination of trace Cu(II) concentrations in seawater using reverse flow injection analysis coupled with a long path length liquid waveguide capillary cell
    Wang, Ting
    Huang, Yongming
    Zhu, Yong
    Xu, Jin
    Li, Dewang
    Wang, Bin
    Guo, Weidong
    Yuan, Dongxing
    MICROCHEMICAL JOURNAL, 2022, 179
  • [4] Development and application of a shipboard method for spectrophotometric determination of nanomolar dissolved sulfide in estuarine surface waters using reverse flow injection analysis coupled with a long path length liquid waveguide capillary cell
    Wang, Ting
    Huang, Yongming
    Xu, Jin
    Guo, Weidong
    Yuan, Dongxing
    MICROCHEMICAL JOURNAL, 2021, 168
  • [5] Determination of nanomolar concentrations of phosphate in natural waters using flow injection with a long path length liquid waveguide capillary cell and solid-state spectrophotometric detection
    Gimbert, Laura J.
    Haygarth, Philip M.
    Worsfold, Paul J.
    TALANTA, 2007, 71 (04) : 1624 - 1628
  • [6] Rapid speciation of trace iron in rainwater by reverse flow injection analysis coupled to a long path length liquid waveguide capillary cell and spectrophotometric detection
    Huang, Yongming
    Yuan, Dongxing
    Ma, Jian
    Zhang, Min
    Chen, Guohe
    MICROCHIMICA ACTA, 2009, 166 (3-4) : 221 - 228
  • [7] Rapid speciation of trace iron in rainwater by reverse flow injection analysis coupled to a long path length liquid waveguide capillary cell and spectrophotometric detection
    Yongming Huang
    Dongxing Yuan
    Jian Ma
    Min Zhang
    Guohe Chen
    Microchimica Acta, 2009, 166 : 221 - 228
  • [8] Spectrophotometric flow injection determination of dissolved titanium in seawater exploiting in-line nitrilotriacetic acid resin preconcentration and a long path length liquid waveguide capillary cell
    Feng, Sichao
    Wu, Jingfeng
    Yuan, Dongxing
    Huang, Yongming
    Lin, Kunning
    Chen, Yaojin
    ANALYTICA CHIMICA ACTA, 2019, 1053 : 54 - 61
  • [9] Enhanced Sensitivity in Flow Injection Analysis Using a Long Pathlength Liquid Waveguide Capillary Flow Cell for Spectrophotometric Detection
    Jia-Zhong Zhang
    Analytical Sciences, 2006, 22 : 57 - 60
  • [10] Enhanced sensitivity in flow injection analysis using a long pathlength liquid waveguide capillary flow cell for spectrophotometric detection
    Zhang, JZ
    ANALYTICAL SCIENCES, 2006, 22 (01) : 57 - 60