A step forward for the undulation pump total artificial heart

被引:0
|
作者
Abe Y. [1 ]
Chinzei T. [2 ]
Isoyama T. [2 ]
Ono T. [1 ]
Mochizuki S. [1 ]
Saito I. [2 ]
Iwasaki K. [3 ]
Ishimaru M. [1 ]
Baba A. [1 ]
Kouno A. [1 ]
Ozeki T. [2 ]
Tohyama T. [2 ]
Baba K. [1 ]
Imachi K. [1 ]
机构
[1] Department of Biomedical Engineering, Graduate School of Medicine, University of Tokyo, Bunkyo-ku, Tokyo 113-0033
[2] Research Center for Advanced Science, and Technology, University of Tokyo, Tokyo
[3] Department of Mechanical Engineering, Waseda University, Tokyo
关键词
Animal experiment; Artificial heart; Implantable total artificial heart; Undulation pump;
D O I
10.1007/BF02479968
中图分类号
学科分类号
摘要
In the University of Tokyo, various types of total artificial heart (TAH) have been studied. Based on the experiences of TAH research, the development of the undulation pump total artificial heart (UPTAH) started in 1994. The undulation pump is a small-size, continuous-flow, displacement-type blood pump, and the UPTAH is a unique implantable total artificial heart that uses the undulation pump. To date, three models of UPTAH have been developed. The first model, UPTAH1, was developed to investigate the possibility of reducing the size of the device so it could be implanted in small adults, such as Japanese patients, in 1994. The second model, UPTAH2, which was the prototype of the animal experimental model, was developed in 1996 to investigate the possibility of survival with the UPTAH. The third model, UPTAH3, which is the present model, was developed in 1998 to enable long-term survival in animal experiments and to investigate the pathophysiology of the UPTAH. From July 1996 to October 1999, 22 implantations of UPTAH2 or UPTAH3 were performed in goats. In spite of the limitation of their small chest cavity, the UPTAH could be implanted into the chest of all goats. Using UPTAH3, survival of 31 days could be obtained. The research and development of UPTAH are ongoing.
引用
收藏
页码:70 / 74
页数:4
相关论文
共 50 条
  • [1] Development of the undulation pump total artificial heart
    Abe, Y
    Chinzei, T
    Isoyama, T
    Ono, T
    Mochizuki, S
    Mabuchi, K
    Baba, K
    Matsuura, H
    Sun, YP
    Kouno, A
    Atsumi, K
    Fujimasa, I
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 1997, 21 (07) : 665 - 669
  • [3] Third model of the undulation pump total artificial heart
    Abe, Y
    Chinzei, T
    Isoyama, T
    Ono, T
    Mochizuki, S
    Saito, I
    Iwasaki, K
    Ishimaru, M
    Baba, A
    Kouno, A
    Ozeki, T
    Tohyama, T
    Imachi, K
    [J]. ASAIO JOURNAL, 2003, 49 (01) : 123 - 127
  • [4] Implantation of the undulation pump total artificial heart in the goat
    Abe, Y
    Chinzei, T
    Ono, T
    Mochizuki, S
    Saito, I
    Guba, P
    Karita, T
    Sun, YP
    Kouno, A
    Isoyama, T
    Baba, K
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 1999, 23 (10) : 932 - 938
  • [5] Progress in the control system of the undulation pump total artificial heart
    Saito, I
    Chinzei, T
    Abe, Y
    Ishimaru, M
    Mochizuki, S
    Ono, T
    Isoyama, T
    Iwasaki, K
    Kouno, A
    Baba, A
    Ozeki, T
    Takiura, K
    Tohyama, T
    Nakagawa, H
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 2003, 27 (01) : 27 - 33
  • [6] Ripple reduction control of the undulation pump total artificial heart
    Saito, I
    Chinzei, T
    Mochizuki, S
    Abe, Y
    Isoyama, T
    Iwasaki, K
    Suzuki, T
    Karita, T
    Ono, T
    Kouno, A
    Ishimaru, M
    Baba, A
    Ozeki, T
    Tohyama, T
    Kobayashi, S
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 2002, 26 (01) : 40 - 44
  • [7] One month survival with the undulation pump total artificial heart in a goat
    Abe, Y
    Chinzei, T
    Isoyama, T
    Ono, T
    Mochizuki, S
    Saito, I
    Iwasaki, K
    Ishimaru, M
    Karita, T
    Kuono, A
    Baba, K
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 2001, 25 (01) : 69 - 71
  • [8] Compact Ventricular Assist Device and Total Artificial Heart Using Undulation Pump
    Imachi, Kou
    Saito, Itsuro
    Takiura, Koki
    Chinzei, Tsuneo
    Isoyama, Takashi
    Yambe, Tomoyuki
    Shiraishi, Yasuhiro
    Miura, Hidekazu
    Matsuki, Hidetoshi
    Mitamura, Yoshinori
    Inoue, Yusuke
    Okamoto, Eiji
    Umezu, Mitsuo
    Nemoto, Isao
    Abe, Yusuke
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3146 - +
  • [9] Results of Animal Experiments With the Fourth Model of the Undulation Pump Total Artificial Heart
    Abe, Yusuke
    Isoyama, Takashi
    Saito, Itsuro
    Shi, Wei
    Inoue, Yusuke
    Ishii, Kohei
    Nakagawa, Hidemoto
    Ono, Toshiya
    Ono, Minoru
    Imachi, Kou
    [J]. ARTIFICIAL ORGANS, 2011, 35 (08) : 781 - 790
  • [10] 1/R control method applied to Undulation Pump Total Artificial Heart(UPTAH)
    Ishimaru, M.
    Chinzei, T.
    Abe, Y.
    Ono, T.
    Saitoh, I.
    Mochiduki, S.
    Isoyama, T.
    Iwasaki, K.
    Kohno, A.
    Karita, T.
    Baba, A.
    Baba, K.
    Imachi, K.
    [J]. ASAIO Journal, 2000, 46 (02)