One month survival with the undulation pump total artificial heart in a goat

被引:0
|
作者
Abe, Y [1 ]
Chinzei, T [1 ]
Isoyama, T [1 ]
Ono, T [1 ]
Mochizuki, S [1 ]
Saito, I [1 ]
Iwasaki, K [1 ]
Ishimaru, M [1 ]
Karita, T [1 ]
Kuono, A [1 ]
Baba, K [1 ]
Imachi, K [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Biomed Engn, Tokyo, Japan
关键词
undulation pump; total artificial heart;
D O I
10.1046/j.1525-1594.2001.06655-5.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The undulation pump is a small continuous flow displacement-type blood pump. The undulation pump total artificial heart (UPTAH) is a unique implantable total artificial heart using undulation pumps. An adult female goat weighing 45.8 kg was used for implantation. The natural heart was replaced with the UPTAH under extracorporal circulation. The cardiac output (CO) was maintained to 100 ml/kg/min by controlling the right pump manually. To prevent lung edema, the left pump was controlled automatically to maintain the left atrial pressure below 20 mm Hg. The CO was maintained for 2 weeks. Thereafter, the CO gradually decreased. The goat suddenly died because of a brain stroke on the 31st postoperative day. At autopsy, the cavity of the left atrial cuff was almost occupied by the big pannus-like thrombus, which was thought to be the cause of death. Improvement of the atrial cuff is necessary to obtain longer survival and is being modified. No thrombus was found inside the pumps. However, temperature rise in a left motor was a problem. Improvement of the efficiency in a motor is necessary. Although many problems still remained, 1 month survival could be obtained with this unique implantable TAH using continuous flow displacement-type blood pumps.
引用
收藏
页码:69 / 71
页数:3
相关论文
共 50 条
  • [1] Implantation of the undulation pump total artificial heart in the goat
    Abe, Y
    Chinzei, T
    Ono, T
    Mochizuki, S
    Saito, I
    Guba, P
    Karita, T
    Sun, YP
    Kouno, A
    Isoyama, T
    Baba, K
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 1999, 23 (10) : 932 - 938
  • [2] Development of the undulation pump total artificial heart
    Abe, Y
    Chinzei, T
    Isoyama, T
    Ono, T
    Mochizuki, S
    Mabuchi, K
    Baba, K
    Matsuura, H
    Sun, YP
    Kouno, A
    Atsumi, K
    Fujimasa, I
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 1997, 21 (07) : 665 - 669
  • [4] Third model of the undulation pump total artificial heart
    Abe, Y
    Chinzei, T
    Isoyama, T
    Ono, T
    Mochizuki, S
    Saito, I
    Iwasaki, K
    Ishimaru, M
    Baba, A
    Kouno, A
    Ozeki, T
    Tohyama, T
    Imachi, K
    [J]. ASAIO JOURNAL, 2003, 49 (01) : 123 - 127
  • [5] A step forward for the undulation pump total artificial heart
    Abe Y.
    Chinzei T.
    Isoyama T.
    Ono T.
    Mochizuki S.
    Saito I.
    Iwasaki K.
    Ishimaru M.
    Baba A.
    Kouno A.
    Ozeki T.
    Tohyama T.
    Baba K.
    Imachi K.
    [J]. Journal of Artificial Organs, 2000, 3 (2) : 70 - 74
  • [6] Progress in the control system of the undulation pump total artificial heart
    Saito, I
    Chinzei, T
    Abe, Y
    Ishimaru, M
    Mochizuki, S
    Ono, T
    Isoyama, T
    Iwasaki, K
    Kouno, A
    Baba, A
    Ozeki, T
    Takiura, K
    Tohyama, T
    Nakagawa, H
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 2003, 27 (01) : 27 - 33
  • [7] Ripple reduction control of the undulation pump total artificial heart
    Saito, I
    Chinzei, T
    Mochizuki, S
    Abe, Y
    Isoyama, T
    Iwasaki, K
    Suzuki, T
    Karita, T
    Ono, T
    Kouno, A
    Ishimaru, M
    Baba, A
    Ozeki, T
    Tohyama, T
    Kobayashi, S
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 2002, 26 (01) : 40 - 44
  • [8] Pathophysiologic study of goats with undulation pump total artificial heart: Those that survived for more than 1 month
    Baba, A
    Vasku, J
    Dobsak, P
    Saito, I
    Ishimaru, M
    Isoyama, T
    Takiura, K
    Ozeki, T
    Abe, Y
    Chinzei, T
    Imachi, K
    [J]. ASAIO JOURNAL, 2003, 49 (04) : 463 - 468
  • [9] Forty six days survival with the smallest implantable total artificial heart (THA), undulation pump TAH(UPTAH)
    Imachi, K.
    Abe, Y.
    Chinzei, T.
    Ono, T.
    Saito, I.
    Mochizuki, S.
    Ishimaru, M.
    Isoyama, T.
    Karita, T.
    Baba, A.
    Iwasaki, K.
    Kouno, A.
    Ozeki, T.
    Toyama, T.
    Baba, K.
    [J]. ASAIO Journal, 2000, 46 (02)
  • [10] Compact Ventricular Assist Device and Total Artificial Heart Using Undulation Pump
    Imachi, Kou
    Saito, Itsuro
    Takiura, Koki
    Chinzei, Tsuneo
    Isoyama, Takashi
    Yambe, Tomoyuki
    Shiraishi, Yasuhiro
    Miura, Hidekazu
    Matsuki, Hidetoshi
    Mitamura, Yoshinori
    Inoue, Yusuke
    Okamoto, Eiji
    Umezu, Mitsuo
    Nemoto, Isao
    Abe, Yusuke
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3146 - +