Compact Ventricular Assist Device and Total Artificial Heart Using Undulation Pump

被引:0
|
作者
Imachi, Kou [1 ]
Saito, Itsuro [3 ]
Takiura, Koki [4 ]
Chinzei, Tsuneo [3 ]
Isoyama, Takashi [2 ]
Yambe, Tomoyuki [4 ]
Shiraishi, Yasuhiro [4 ]
Miura, Hidekazu [5 ]
Matsuki, Hidetoshi [5 ]
Mitamura, Yoshinori [6 ]
Inoue, Yusuke [6 ]
Okamoto, Eiji [7 ]
Umezu, Mitsuo [8 ]
Nemoto, Isao [8 ]
Abe, Yusuke [2 ]
机构
[1] Tohoku Univ, TUBERO, Sendai, Miyagi 980, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Biomed Engn, Tokyo, Japan
[3] Univ Tokyo, RCAST, Tokyo, Japan
[4] Tohoku Univ, IDAC, Sendai, Miyagi, Japan
[5] Tohoku Univ, Grad Sch Engn, Sendai, Miyagi, Japan
[6] Hokkaido Univ, Grad Sch Engn, Sapporo, Hokkaido, Japan
[7] Hokkaido Tokai Univ, Fac Engn, Sapporo, Hokkaido, Japan
[8] Nemoto Project Ind Co Ltd, Chiba, Japan
关键词
Artificial heart; total artificial heart; Mechanical circulatory assist; Undulation pump; TETS (Transcutaneous energy transmission sustem);
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fully implantable VAD and TAH are eager to be developed as destination therapy for the severe heart failure patients who do not be candidate of heart transplantation. We have been developing fully implantable VAD and TAH using undulation pump(UP) under multi-institutional cooperative project supported by the Program for Promotion of Fundamental Studies in Health Sciences of the Pharmaceuticals and Medical Device Agency(PMDA). The objective of this presentation is to introduce the present status of their development. UP is a kind of rotary blood pump in which the rotational motion of brushless DC motor is converted to undulation motion of a disc in the pump housing, that squeezes the blood from the inlet to the outlet, and has many advantages; very compact, can produce arbitrary blood flow pattern from pulasatile to continuous, doesn't require heart valve and compliance chamber. UPVAD is composed of UP, undulation shaft and blushless DC motor, which has 69 mm in diameter, 35 mm thick and 331 g of weight. UPTAH is composed of two independent Ups having own undulation shaft and blushless DC motor, which has 76 mm in diameter, 78 mm long and 530 g of weight. TETS has 93 % of DC-DC efficiency. Drive & control unit, lithium-polymer internal batteries and transcutaneous bi-directional information tansmission systemare incorporated into a case having 93x93x40 mm. VAD and TAH could be implanted into the chest cavity of goat weighing between 38 and 79 Kg. In VAD experiments, 4 goats survived for more than 4 weeks with total implantation and 4 months survivors was the longest with only UP implantation. In TAH experiments, 7 goats survived for more than one month. The longest survivors was 63 days. The results show the feasibility of the systems for the future clinical application
引用
收藏
页码:3146 / +
页数:2
相关论文
共 50 条
  • [1] Sucking control of the undulation pump ventricular assist device
    Saito, I
    Chinzei, T
    Abe, Y
    Isoyama, T
    Ono, T
    Kouno, A
    Mitsumune, N
    Sugino, A
    Shi, W
    Nakagawa, H
    Imachi, K
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2006, 29 (05): : 534 - 534
  • [2] Development of the undulation pump total artificial heart
    Abe, Y
    Chinzei, T
    Isoyama, T
    Ono, T
    Mochizuki, S
    Mabuchi, K
    Baba, K
    Matsuura, H
    Sun, YP
    Kouno, A
    Atsumi, K
    Fujimasa, I
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 1997, 21 (07) : 665 - 669
  • [3] Synchronization of the undulation pump ventricular assist device with natural heartbeat
    不详
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 911 - 911
  • [5] Third model of the undulation pump total artificial heart
    Abe, Y
    Chinzei, T
    Isoyama, T
    Ono, T
    Mochizuki, S
    Saito, I
    Iwasaki, K
    Ishimaru, M
    Baba, A
    Kouno, A
    Ozeki, T
    Tohyama, T
    Imachi, K
    [J]. ASAIO JOURNAL, 2003, 49 (01) : 123 - 127
  • [6] Implantation of the undulation pump total artificial heart in the goat
    Abe, Y
    Chinzei, T
    Ono, T
    Mochizuki, S
    Saito, I
    Guba, P
    Karita, T
    Sun, YP
    Kouno, A
    Isoyama, T
    Baba, K
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 1999, 23 (10) : 932 - 938
  • [7] A step forward for the undulation pump total artificial heart
    Abe Y.
    Chinzei T.
    Isoyama T.
    Ono T.
    Mochizuki S.
    Saito I.
    Iwasaki K.
    Ishimaru M.
    Baba A.
    Kouno A.
    Ozeki T.
    Tohyama T.
    Baba K.
    Imachi K.
    [J]. Journal of Artificial Organs, 2000, 3 (2) : 70 - 74
  • [8] Preliminary Study of Physiological Control for the Undulation Pump Ventricular Assist Device
    Saito, Itsuro
    Ishii, Kohei
    Isoyama, Takashi
    Ono, Toshiya
    Nakagawa, Hidemoto
    Shi, Wei
    Inoue, Yusuke
    Abe, Yusuke
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5218 - 5221
  • [9] Gastrointestinal Bleeding in Ventricular Assist Device and Total Artificial Heart Implantations
    Lachar, Jatinder
    Christopher, Sanah
    Flattery, Maureen
    Shah, Keyur
    Tang, Daniel G.
    Smallfield, Melissa C.
    Cooke, Richard H.
    Kasirajan, Vigneshwar
    Cheng, Jianfeng
    Smallfield, George
    [J]. GASTROENTEROLOGY, 2014, 146 (05) : S322 - S322
  • [10] Progress in the control system of the undulation pump total artificial heart
    Saito, I
    Chinzei, T
    Abe, Y
    Ishimaru, M
    Mochizuki, S
    Ono, T
    Isoyama, T
    Iwasaki, K
    Kouno, A
    Baba, A
    Ozeki, T
    Takiura, K
    Tohyama, T
    Nakagawa, H
    Imachi, K
    [J]. ARTIFICIAL ORGANS, 2003, 27 (01) : 27 - 33