Comparison of the effect on bone healing process of different implants used in minimally invasive plate osteosynthesis: limited contact dynamic compression plate versus locking compression plate

被引:0
|
作者
Zichao Xue
Haitao Xu
Haoliang Ding
Hui Qin
Zhiquan An
机构
[1] Shanghai Jiao Tong University Affiliated Sixth People’s Hospital,Department of Orthopedic Surgery
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Minimally invasive plate osteosynthesis (MIPO) has been widely accepted because of its satisfactory clinical outcomes. However, the implant construct that works best for MIPO remains controversial. Different plate designs result in different influence mechanisms to blood flow. In this study, we created ulnar fractures in 42 beagle dogs and fixed the fractures using MIPO. The dogs were randomly divided into two groups and were fixed with a limited contact dynamic compression plate (LC-DCP) or a locking compression plate (LCP). Our study showed that with MIPO, there was no significant difference between the LCP and the LC-DCP in terms of fracture fixation, bone formation, or mineralization. Combined with the previous literature, we inferred that the healing process is affected by the quality of fracture reduction more than plate selection.
引用
收藏
相关论文
共 50 条
  • [41] Comparison of the Effects of Two Screw Insertion Patterns on Bone Fragment Translocation in a 3.5 mm Dynamic Compression Plate and a 3.5 mm Limited-Contact Dynamic Compression Plate
    Csiszer, Amie B.
    Daly, Curt M.
    Dyce, Jonathan
    Litsky, Alan S.
    Olmstead, Marvin L.
    VETERINARY SURGERY, 2012, 41 (02) : 300 - 306
  • [42] An in vitro biomechanical comparison of a limited-contact dynamic compression plate fixation with a dynamic compression plate fixation of osteotomized equine third metacarpal bones
    Sod, GA
    Hubert, JD
    Martin, GS
    Gill, MS
    VETERINARY SURGERY, 2005, 34 (06) : 579 - 586
  • [43] Effectiveness of non-uniform thickness on a locking compression plate used as a biodegradable bone implant plate
    Singh, Gourav
    Pandey, Ajay
    Chandra, Girish
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2022, 37 (03) : 429 - 446
  • [44] CLINICAL-EXPERIENCE WITH TITANIUM IMPLANTS, ESPECIALLY WITH THE LIMITED CONTACT DYNAMIC COMPRESSION PLATE SYSTEM
    MATTER, P
    BURCH, HB
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1990, 109 (06) : 311 - 313
  • [45] Distal Tibial Fracture Fixation with Locking Compression Plate (LCP) Using the Minimally Invasive Percutaneous Osteosynthesis (MIPO) Technique
    Abid Mushtaq
    Rizwan Shahid
    Muhammad Asif
    Mohammad Maqsood
    European Journal of Trauma and Emergency Surgery, 2009, 35 : 159 - 164
  • [46] In Vitro Biomechanical Comparison of a 4.5mm Narrow Locking Compression Plate Construct Versus a 4.5mm Limited Contact Dynamic Compression Plate Construct for Arthrodesis of the Equine Proximal Interphalangeal Joint
    Ahern, Benjamin J.
    Showalter, Brent L.
    Elliott, Dawn M.
    Richardson, Dean W.
    Getman, Liberty M.
    VETERINARY SURGERY, 2013, 42 (03) : 335 - 339
  • [47] Distal Tibial Fracture Fixation with Locking Compression Plate (LCP) Using the Minimally Invasive Percutaneous Osteosynthesis (MIPO) Technique
    Mushtaq, Abid
    Shahid, Rizwan
    Asif, Muhammad
    Maqsood, Mohammad
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2009, 35 (02) : 159 - 164
  • [48] In vitro biomechanical evaluation and comparison of a new prototype locking plate and a limited-contact self compression plate for equine fracture repair
    Quinteros, D. D.
    Garcia-Lopez, J. M.
    Abuja, G. A.
    Tarkanian, M.
    Maranda, L. S.
    Bubeck, K.
    Kowaleski, M. P.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2012, 25 (04) : 273 - 280
  • [49] Biomechanical considerations in plate osteosynthesis: the effect of plate-to-bone compression with and without angular screw stability
    Stoffel, K.
    Lorenz, K. U.
    Kuster, M. S.
    SWISS MEDICAL WEEKLY, 2009, 139 (23-24) : 28S - 28S
  • [50] Biomechanical Considerations in Plate Osteosynthesis: The Effect of Plate-to-Bone Compression With and Without Angular Screw Stability
    Stoffel, Karl
    Lorenz, Kai-Uwe
    Kuster, Markus S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (06) : 362 - 368