Embossed radiography utilizing energy subtraction

被引:6
|
作者
Osawa A. [1 ]
Watanabe M. [1 ]
Sato E. [2 ]
Matsukiyo H. [1 ]
Enomoto T. [1 ]
Nagao J. [1 ]
Abderyim P. [3 ]
Aizawa K. [4 ]
Tanaka E. [5 ]
Mori H. [6 ]
Kawai T. [7 ]
Ehara S. [8 ]
Sato S. [9 ]
Ogawa A. [10 ]
Onagawa J. [11 ]
机构
[1] 3rd Department of Surgery, Toho University, School of Medicine, Meguro-ku, Tokyo 153-8515
[2] Department of Physics, Iwate Medical University, Yahaba 028-3694
[3] Department of Computer and Information Sciences, Faculty of Engineering, Iwate University, Morioka 020-8551
[4] Tokyo Medical University, Shinjyuku-ku, Tokyo 160-8402
[5] Department of Nutritional Science, Faculty of Applied Bio-science, Tokyo University of Agriculture, Setagaya-ku, Tokyo 156-8502
[6] Department of Cardiac Physiology, National Cardiovascular Center Research Institute, Suita, Osaka 565-8565
[7] Electron Tube Division #2, Hamamatsu Photonics K.K, Iwata, Shizuoka 438-0193
[8] Department of Radiology, School of Medicine, Iwate Medical University, Morioka 020-8505
[9] Department of Microbiology, School of Medicine, Iwate Medical University, Morioka 020-8505
[10] Department of Neurosurgery, School of Medicine, Iwate Medical University, Morioka 020-8505
[11] Department of Electronics, Faculty of Engineering, Tohoku Gakuin University, Tagajo, Miyagi 985-8537
基金
日本科学技术振兴机构;
关键词
Contrast resolution; Digital subtraction; Embossed radiography; Energy subtraction; Polychromatic X-rays;
D O I
10.1007/s12194-008-0048-8
中图分类号
学科分类号
摘要
Currently, it is difficult to carry out refraction-contrast radiography by using a conventional X-ray generator. Thus, we developed an embossed radiography system utilizing dual-energy subtraction for decreasing the absorption contrast in unnecessary regions, and the contrast resolution of a target region was increased by use of image-shifting subtraction and a linear-contrast system in a flat panel detector (FPD). The X-ray generator had a 100-μm-focus tube. Energy subtraction was performed at tube voltages of 45 and 65 kV, a tube current of 0.50 mA, and an X-ray exposure time of 5.0 s. A 1.0-mm-thick aluminum filter was used for absorbing low-photon-energy bremsstrahlung X-rays. Embossed radiography was achieved with cohesion imaging by use of the FPD with pixel sizes of 48 × 48 μm, and the shifting dimension of an object in the horizontal direction ranged from 100 to 200 μm. At a shifting distance of 100 μm, the spatial resolutions in the horizontal and vertical directions measured with a lead test chart were both 83 μm. In embossed radiography of non-living animals, we obtained high-contrast embossed images of fine bones, gadolinium oxide particles in the kidney, and coronary arteries approximately 100 μm in diameter. © 2008 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:77 / 86
页数:9
相关论文
共 50 条
  • [41] Assessment of Coronary Artery Calcium Using Dual-Energy Subtraction Digital Radiography
    Mafi, John N.
    Fei, Baowei
    Roble, Sharon
    Dota, Anthony
    Katrapati, Prashanth
    Bezerra, Hiram G.
    Wang, Hesheng
    Wang, Wei
    Ciancibello, Leslie
    Costa, Marco
    Simon, Daniel I.
    Orringer, Carl E.
    Gilkeson, Robert C.
    JOURNAL OF DIGITAL IMAGING, 2012, 25 (01) : 129 - 136
  • [42] Development of Artificial Intelligence-Based Dual-Energy Subtraction for Chest Radiography
    Yamazaki, Asumi
    Koshida, Akane
    Tanaka, Toshimitsu
    Seki, Masashi
    Ishida, Takayuki
    APPLIED SCIENCES-BASEL, 2023, 13 (12):
  • [43] Role of digital tomosynthesis and dual energy subtraction digital radiography in detecting pulmonary nodules
    Kumar, Sarvana G.
    Garg, Mandeep Kumar
    Khandelwal, Niranjan
    Gupta, Pankaj
    Gupta, Dheeraj
    Aggarwal, Ashutosh Nath
    Bansal, Subash Chand
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (07) : 1383 - 1391
  • [44] The clinical utility of a one-shot energy subtraction method for thoracic spine radiography
    Sasagawa, Takeshi
    Kunogi, Junichi
    Masuyama, Shigeru
    Ogihara, Satoshi
    Takeuchi, Yosuke
    Takeshita, Yujiro
    Fukushima, Masayoshi
    Kamiya, Naokazu
    Murakami, Hideki
    Tsuchiya, Hiroyuki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2012, 17 (04) : 346 - 351
  • [45] THE DETECTION OF INVITRO PRODUCED PERIODONTAL BONE-LESIONS BY CONVENTIONAL RADIOGRAPHY AND PHOTOGRAPHIC SUBTRACTION RADIOGRAPHY USING OBSERVERS AND QUANTITATIVE DIGITAL SUBTRACTION RADIOGRAPHY
    JANSSEN, PTM
    HELDERMAN, WHV
    VANAKEN, J
    JOURNAL OF CLINICAL PERIODONTOLOGY, 1989, 16 (06) : 335 - 341
  • [46] An in vitro evaluation of a subtraction radiography system.
    Rawlinson, A
    Ellwood, RP
    Davies, RM
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1067 - 1067
  • [47] DIGITAL K-EDGE SUBTRACTION RADIOGRAPHY
    KRUGER, RA
    MISTRETTA, CA
    CRUMMY, AB
    SACKETT, JF
    GOODSITT, MM
    RIEDERER, SJ
    HOUK, TL
    SHAW, CG
    FLEMING, D
    RADIOLOGY, 1977, 125 (01) : 243 - 245
  • [48] DIAGNOSIS OF BONE-LESIONS BY SUBTRACTION RADIOGRAPHY
    RETHMAN, M
    RUTTIMAN, U
    ONEAL, R
    WEBBER, R
    DAVIS, A
    GREENSTEIN, G
    WOODYARD, S
    JOURNAL OF PERIODONTOLOGY, 1985, 56 (06) : 324 - 329
  • [49] DIGITAL SUBTRACTION RADIOGRAPHY OF THE RESPIRATORY-TRACT
    PERLMUTTERCREMER, N
    PEDIATRIC RADIOLOGY, 1984, 14 (04) : 255 - 255
  • [50] The performance of projective standardization for digital subtraction radiography
    Mol, A
    Dunn, SM
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2003, 96 (03): : 373 - 382