Embossed radiography utilizing energy subtraction

被引:6
|
作者
Osawa A. [1 ]
Watanabe M. [1 ]
Sato E. [2 ]
Matsukiyo H. [1 ]
Enomoto T. [1 ]
Nagao J. [1 ]
Abderyim P. [3 ]
Aizawa K. [4 ]
Tanaka E. [5 ]
Mori H. [6 ]
Kawai T. [7 ]
Ehara S. [8 ]
Sato S. [9 ]
Ogawa A. [10 ]
Onagawa J. [11 ]
机构
[1] 3rd Department of Surgery, Toho University, School of Medicine, Meguro-ku, Tokyo 153-8515
[2] Department of Physics, Iwate Medical University, Yahaba 028-3694
[3] Department of Computer and Information Sciences, Faculty of Engineering, Iwate University, Morioka 020-8551
[4] Tokyo Medical University, Shinjyuku-ku, Tokyo 160-8402
[5] Department of Nutritional Science, Faculty of Applied Bio-science, Tokyo University of Agriculture, Setagaya-ku, Tokyo 156-8502
[6] Department of Cardiac Physiology, National Cardiovascular Center Research Institute, Suita, Osaka 565-8565
[7] Electron Tube Division #2, Hamamatsu Photonics K.K, Iwata, Shizuoka 438-0193
[8] Department of Radiology, School of Medicine, Iwate Medical University, Morioka 020-8505
[9] Department of Microbiology, School of Medicine, Iwate Medical University, Morioka 020-8505
[10] Department of Neurosurgery, School of Medicine, Iwate Medical University, Morioka 020-8505
[11] Department of Electronics, Faculty of Engineering, Tohoku Gakuin University, Tagajo, Miyagi 985-8537
基金
日本科学技术振兴机构;
关键词
Contrast resolution; Digital subtraction; Embossed radiography; Energy subtraction; Polychromatic X-rays;
D O I
10.1007/s12194-008-0048-8
中图分类号
学科分类号
摘要
Currently, it is difficult to carry out refraction-contrast radiography by using a conventional X-ray generator. Thus, we developed an embossed radiography system utilizing dual-energy subtraction for decreasing the absorption contrast in unnecessary regions, and the contrast resolution of a target region was increased by use of image-shifting subtraction and a linear-contrast system in a flat panel detector (FPD). The X-ray generator had a 100-μm-focus tube. Energy subtraction was performed at tube voltages of 45 and 65 kV, a tube current of 0.50 mA, and an X-ray exposure time of 5.0 s. A 1.0-mm-thick aluminum filter was used for absorbing low-photon-energy bremsstrahlung X-rays. Embossed radiography was achieved with cohesion imaging by use of the FPD with pixel sizes of 48 × 48 μm, and the shifting dimension of an object in the horizontal direction ranged from 100 to 200 μm. At a shifting distance of 100 μm, the spatial resolutions in the horizontal and vertical directions measured with a lead test chart were both 83 μm. In embossed radiography of non-living animals, we obtained high-contrast embossed images of fine bones, gadolinium oxide particles in the kidney, and coronary arteries approximately 100 μm in diameter. © 2008 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:77 / 86
页数:9
相关论文
共 50 条
  • [31] A DIGITAL SUBTRACTION TECHNIQUE FOR DENTAL RADIOGRAPHY
    GRONDAHL, HG
    GRONDAHL, K
    WEBBER, RL
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1983, 55 (01): : 96 - 102
  • [32] CALIBRATION ERRORS IN DIGITAL SUBTRACTION RADIOGRAPHY
    WEBBER, RL
    RUTTIMANN, UE
    HEAVEN, TJ
    JOURNAL OF PERIODONTAL RESEARCH, 1990, 25 (05) : 268 - 275
  • [33] A grid computing approach to subtraction radiography
    Manana, Gabriel
    Romero, Eduardo
    Gonzalez, Fabio
    2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 3325 - +
  • [34] Screening for Coronary Artery Calcification Using Dual Energy Subtraction Radiography: A Pilot Study
    Novak, R.
    Gilkeson, R.
    Novak, N.
    DuPont, E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [35] Improved detection of small lung cancers with dual-energy subtraction chest radiography
    Li, Feng
    Engelmann, Roger
    Doi, Kunio
    MacMahon, Heber
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) : 886 - 891
  • [36] Dual energy subtraction digital radiography - Technical considerations, clinical applications, and imaging pitfalls
    Gilkeson, Robert C.
    Sachs, Peter B.
    JOURNAL OF THORACIC IMAGING, 2006, 21 (04) : 303 - 313
  • [37] Single exposure dual energy subtraction computed radiography of the chest for the assessment of nodule detection
    Hartman, TE
    Aughenbaugh, GL
    Harms, GF
    Sykes, AG
    Weaver, AL
    Hodge, D
    RADIOLOGY, 1998, 209P : 410 - 410
  • [38] An image reconstruction method based on machine learning for dual-energy subtraction radiography
    Kitamura, Yoshiro
    Yamada, Masahiko
    Ito, Wataru
    MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914
  • [39] Dual-energy subtraction chest radiography: What to look for beyond calcified nodules
    Kuhlman, Janet E.
    Collins, Jannette
    Brooks, Gregory N.
    Yandow, Donald R.
    Broderick, Lynn S.
    RADIOGRAPHICS, 2006, 26 (01) : 79 - U149
  • [40] Assessment of Coronary Artery Calcium Using Dual-Energy Subtraction Digital Radiography
    John N. Mafi
    Baowei Fei
    Sharon Roble
    Anthony Dota
    Prashanth Katrapati
    Hiram G. Bezerra
    Hesheng Wang
    Wei Wang
    Leslie Ciancibello
    Marco Costa
    Daniel I. Simon
    Carl E. Orringer
    Robert C. Gilkeson
    Journal of Digital Imaging, 2012, 25 : 129 - 136