Stress distribution in the supraspinatus tendon after tendon repair - Suture anchors versus transosseous suture fixation

被引:52
|
作者
Sano, Hirotaka
Yamashita, Takeshi
Wakabayashi, Ikuko
Itoi, Eiji
机构
[1] Tohoku Univ, Sch Med, Dept Orthopaed Surg, Sendai, Miyagi 980, Japan
[2] Tohoku Univ, Grad Sch Engn, Dept Mat Proc, Sendai, Miyagi 980, Japan
[3] Akitaken Taiheirouikuen Hosp Disabled Children, Dept Orthopaed Surg, Akita, Japan
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2007年 / 35卷 / 04期
关键词
finite element method; stress concentration; rotator cuff repair; rerupture; single-row fixation; double-row fixation; transosseous suture fixation;
D O I
10.1177/0363546506296310
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The stress concentration at the site of supraspinatus tendon repair, either by suture anchor fixation or by transosseous suture fixation, has not been fully clarified. Hypothesis: Suture anchor fixation showed higher stress concentrations in the tendon than did transosseous suture fixation. Study Design: Controlled laboratory study. Methods: Three finite element models were developed based on a previously published model of normal supraspinatus tendon (0 degrees abduction). Single-row fixation, double-row fixation, and transosseous suture fixation were simulated. A tensile force was applied to the proximal end of the supraspinatus tendon to simulate its contraction force. Results: In the single-row model, the stress appeared from the site of the anchor and extended into the proximal tendon. The highest stress concentration was observed on the bursal surface of the tendon. The double-row model showed a similar pattern to the single-row model except that the stress concentration was observed only around the medial anchor. In the transosseous model, the stress appeared from the attachment site to a bony trough, which extended proximally into the tendon substance. No significant stress concentration was observed inside the tendon. Conclusion: Both single-row and double-row fixations showed higher stress concentration inside the tendon than did transosseous suture fixation. Clinical Relevance: A high stress concentration might be a cause of the rerupture often observed after arthroscopic cuff repair using suture anchors.
引用
收藏
页码:542 / 546
页数:5
相关论文
共 50 条
  • [1] Outcomes following quadriceps tendon repair using transosseous tunnels versus suture anchors: A systematic review
    Mehta, Anuj, V
    Wilson, Christopher
    King, Tonya S.
    Gallo, Robert A.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (03): : 339 - 344
  • [2] Biomechanical Comparison of Transosseous Versus Suture Anchor Repair of the Subscapularis Tendon
    Wheeler, Daniel J.
    Garabekyan, Tigran
    Lugo, Roberto
    Buckley, Jenni M.
    Jones, Christopher
    Lotz, Marielena
    Lotz, Jeffery C.
    Ma, C. Benjamin
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (04): : 444 - 450
  • [3] Biomechanical Analysis of Patellar Tendon Repair With Knotless Suture Anchor Tape Versus Transosseous Suture
    Massey, Patrick A.
    Myers, Mitchell
    McClary, Kaylan
    Brown, Jimmy
    Barton, R. Shane
    Solitro, Giovanni F.
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (10)
  • [4] Pectoralis major tendon repair: a biomechanical study of suture button versus transosseous suture techniques
    Thomas, William
    Gheduzzi, Sabina
    Packham, Iain
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (09) : 2617 - 2623
  • [5] Pectoralis major tendon repair: a biomechanical study of suture button versus transosseous suture techniques
    William Thomas
    Sabina Gheduzzi
    Iain Packham
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 2617 - 2623
  • [6] Repair of patellar tendon rupture with suture anchors
    Capiola, David
    Re, Louis
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (08): : 906.e1 - 906.e4
  • [7] The Use of Suture Anchors to Repair the Ruptured Quadriceps Tendon
    Bushnell, Brandon D.
    Whitener, George B.
    Rubright, James H.
    Creighton, R. Alexander
    Logel, Kevin J.
    Wood, Mark L.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (06) : 407 - 413
  • [8] Biomechanical Comparison of Onlay Distal Biceps Tendon Repair: All-Suture Anchors Versus Titanium Suture Anchors
    Otto, Alexander
    Mehl, Julian
    Obopilwe, Elifho
    Cote, Mark
    Lacheta, Lucca
    Scheiderer, Bastian
    Imhoff, Andreas B.
    Mazzocca, Augustus D.
    Siebenlist, Sebastian
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (10): : 2478 - 2483
  • [9] Repair of quadriceps tendon ruptures using suture anchors
    Richards, DP
    Barber, FA
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (05): : 556 - 559
  • [10] The use of suture anchors to repair the ruptured quadriceps tendon
    Bushnell, Brandon D.
    Whitener, George B.
    Rubright, James H.
    Creighton, R. Alexander
    Logel, Kevin J.
    Wood, Mark L.
    [J]. CURRENT ORTHOPAEDIC PRACTICE, 2008, 19 (03): : 314 - 320