Biomechanical Comparison of Onlay Distal Biceps Tendon Repair: All-Suture Anchors Versus Titanium Suture Anchors

被引:25
|
作者
Otto, Alexander [1 ,2 ,3 ]
Mehl, Julian [2 ]
Obopilwe, Elifho [1 ]
Cote, Mark [1 ]
Lacheta, Lucca [2 ]
Scheiderer, Bastian [2 ]
Imhoff, Andreas B. [2 ]
Mazzocca, Augustus D. [1 ]
Siebenlist, Sebastian [2 ]
机构
[1] Univ Connecticut, UConn Musculoskeletal Inst, Dept Orthopaed Surg, 263 Farmington Ave, Farmington, CT 06032 USA
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Orthopaed Sports Med, Munich, Germany
[3] Univ Hosp Augsburg, Dept Trauma Orthopaed Plast & Hand Surg, Augsburg, Germany
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2019年 / 47卷 / 10期
关键词
distal biceps brachii tendon; biomechanics of tendon; elbow; aging athlete; all-suture anchor; titanium suture anchor; INTRAMEDULLARY CORTICAL BUTTON; SURGICAL-TREATMENT; RUPTURES; ENDOBUTTON; FIXATION;
D O I
10.1177/0363546519860489
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A rupture of the distal biceps tendon is the most common tendon rupture of the elbow and has received increased attention in the past few years. Newly developed all-suture anchors have the potential to minimize surgical trauma and the risk of adverse events because of the use of flexible drills and smaller drill diameters. Purpose/Hypothesis: The purpose was to biomechanically compare all-suture anchors and titanium suture anchors for distal biceps tendon repair in cadaveric specimens. The hypothesis was that all-suture anchors would show no differences in load to failure or displacement under cyclic loading compared with titanium suture anchors. Study Design: Controlled laboratory study. Methods: Sixteen unpaired, fresh-frozen human cadaveric elbows were randomized to 2 groups, which underwent onlay distal biceps tendon repair with 2 anchors. Bone mineral density at the radial tuberosity was evaluated in each specimen. In the first group, distal biceps tendon repair was performed using all-suture anchors. In the second group, titanium suture anchors were applied. After cyclic loading for 3000 cycles, the repair constructs were loaded to failure. The peak load to failure as well as repair construct stiffness and mode of failure were determined. Results: The mean (+/- SD) peak load was 293.53 +/- 122.15 N for all-suture anchors and 280.02 +/- 69.34 N for titanium suture anchors (P = .834); mean stiffness was 19.78 +/- 2.95 N/mm and 19.30 +/- 4.98 N/mm, respectively (P = .834). The mode of failure was anchor pullout for all specimens during load to failure. At the proximal position, all-suture anchors showed a displacement of 1.53 +/- 0.80 mm, and titanium suture anchors showed a displacement of 0.81 +/- 0.50 mm (P = .021) under cyclic loading. At the distal position, a displacement of 1.86 +/- 1.04 mm for all-suture anchors and 1.53 +/- 1.15 mm for titanium suture anchors was measured (P = .345). A positive correlation between bone mineral density and load to failure was observed (r = 0.605; P = .013). Conclusion: All-suture anchors were biomechanically equivalent at time zero to titanium suture anchors for onlay distal biceps tendon repair. While the proximally placed all-suture anchors demonstrated greater displacement than titanium suture anchors, the comparable displacement at the distal position as well as the similar load and mechanism of failure make this difference unlikely to be clinically significant.
引用
收藏
页码:2478 / 2483
页数:6
相关论文
共 50 条
  • [1] All-suture anchors for distal biceps tendon repair: a preliminary outcome study
    Sebastian Lappen
    Stephanie Geyer
    Pavel Kadantsev
    Maximilian Hinz
    Benjamin Kleim
    Hannes Degenhardt
    Andreas B. Imhoff
    Sebastian Siebenlist
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3271 - 3278
  • [2] All-suture anchors for distal biceps tendon repair: a preliminary outcome study
    Lappen, Sebastian
    Geyer, Stephanie
    Kadantsev, Pavel
    Hinz, Maximilian
    Kleim, Benjamin
    Degenhardt, Hannes
    Imhoff, Andreas B.
    Siebenlist, Sebastian
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3271 - 3278
  • [3] Mini-Open Distal Biceps Tendon Repair Using All-Suture Anchors
    Cross, Austin G.
    Jildeh, Toufic R.
    Guo, Eric W.
    Hessburg, Luke T.
    Okoroha, Kelechi R.
    [J]. ARTHROSCOPY TECHNIQUES, 2020, 9 (10): : E1597 - E1600
  • [4] Retrospective Study of the Distal Biceps Tendon Repair Using "All-suture" Soft Anchors
    Metikalc, Sreenivasulu
    Saleh, Zena
    Bader, Dov A.
    Sebastianelli, Wayne J.
    Sherbondy, Paul S.
    [J]. TECHNIQUES IN ORTHOPAEDICS, 2022, 37 (03) : 142 - 148
  • [5] Intramedullary Unicortical Button and All-Suture Anchors Provide Similar Maximum Strength for Onlay Distal Biceps Tendon Repair
    Colantonio, Donald F.
    Le, Anthony H.
    Keeling, Laura E.
    Slaven, Sean E.
    Vippa, Tarun K.
    Helgeson, Melvin D.
    Chang, Edward S.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2022, 38 (02): : 287 - 294
  • [6] Tensionable Distal Biceps Tendon Repair With Intramedullary Knotless All-Suture Anchors and FiberLoop w/FiberTag Suture
    Hsu, Jim C.
    [J]. ARTHROSCOPY TECHNIQUES, 2022, 11 (12): : E2177 - E2183
  • [7] Double intramedullary cortical button versus suture anchors for distal biceps tendon repair: a biomechanical comparison
    Sebastian Siebenlist
    Arne Buchholz
    Julian Zapf
    Gunther H. Sandmann
    Karl F. Braun
    Frank Martetschläger
    Alexander Hapfelmeier
    Tobias M. Kraus
    Andreas Lenich
    Peter Biberthaler
    Florian Elser
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 926 - 933
  • [8] Double intramedullary cortical button versus suture anchors for distal biceps tendon repair: a biomechanical comparison
    Siebenlist, Sebastian
    Buchholz, Arne
    Zapf, Julian
    Sandmann, Gunther H.
    Braun, Karl F.
    Martetschlaeger, Frank
    Hapfelmeier, Alexander
    Kraus, Tobias M.
    Lenich, Andreas
    Biberthaler, Peter
    Elser, Florian
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (03) : 926 - 933
  • [9] Repair of distal biceps tendon rupture with suture anchors
    Scott A. Lynch
    David M. Beard
    P. A. F. H. Renström
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 1999, 7 : 125 - 131
  • [10] Repair of distal biceps tendon rupture with suture anchors
    Lynch, SA
    Beard, DM
    Renström, PAFH
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (02) : 125 - 131