Biomechanical Comparison of Onlay Distal Biceps Tendon Repair: All-Suture Anchors Versus Titanium Suture Anchors

被引:26
|
作者
Otto, Alexander [1 ,2 ,3 ]
Mehl, Julian [2 ]
Obopilwe, Elifho [1 ]
Cote, Mark [1 ]
Lacheta, Lucca [2 ]
Scheiderer, Bastian [2 ]
Imhoff, Andreas B. [2 ]
Mazzocca, Augustus D. [1 ]
Siebenlist, Sebastian [2 ]
机构
[1] Univ Connecticut, UConn Musculoskeletal Inst, Dept Orthopaed Surg, 263 Farmington Ave, Farmington, CT 06032 USA
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Orthopaed Sports Med, Munich, Germany
[3] Univ Hosp Augsburg, Dept Trauma Orthopaed Plast & Hand Surg, Augsburg, Germany
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2019年 / 47卷 / 10期
关键词
distal biceps brachii tendon; biomechanics of tendon; elbow; aging athlete; all-suture anchor; titanium suture anchor; INTRAMEDULLARY CORTICAL BUTTON; SURGICAL-TREATMENT; RUPTURES; ENDOBUTTON; FIXATION;
D O I
10.1177/0363546519860489
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A rupture of the distal biceps tendon is the most common tendon rupture of the elbow and has received increased attention in the past few years. Newly developed all-suture anchors have the potential to minimize surgical trauma and the risk of adverse events because of the use of flexible drills and smaller drill diameters. Purpose/Hypothesis: The purpose was to biomechanically compare all-suture anchors and titanium suture anchors for distal biceps tendon repair in cadaveric specimens. The hypothesis was that all-suture anchors would show no differences in load to failure or displacement under cyclic loading compared with titanium suture anchors. Study Design: Controlled laboratory study. Methods: Sixteen unpaired, fresh-frozen human cadaveric elbows were randomized to 2 groups, which underwent onlay distal biceps tendon repair with 2 anchors. Bone mineral density at the radial tuberosity was evaluated in each specimen. In the first group, distal biceps tendon repair was performed using all-suture anchors. In the second group, titanium suture anchors were applied. After cyclic loading for 3000 cycles, the repair constructs were loaded to failure. The peak load to failure as well as repair construct stiffness and mode of failure were determined. Results: The mean (+/- SD) peak load was 293.53 +/- 122.15 N for all-suture anchors and 280.02 +/- 69.34 N for titanium suture anchors (P = .834); mean stiffness was 19.78 +/- 2.95 N/mm and 19.30 +/- 4.98 N/mm, respectively (P = .834). The mode of failure was anchor pullout for all specimens during load to failure. At the proximal position, all-suture anchors showed a displacement of 1.53 +/- 0.80 mm, and titanium suture anchors showed a displacement of 0.81 +/- 0.50 mm (P = .021) under cyclic loading. At the distal position, a displacement of 1.86 +/- 1.04 mm for all-suture anchors and 1.53 +/- 1.15 mm for titanium suture anchors was measured (P = .345). A positive correlation between bone mineral density and load to failure was observed (r = 0.605; P = .013). Conclusion: All-suture anchors were biomechanically equivalent at time zero to titanium suture anchors for onlay distal biceps tendon repair. While the proximally placed all-suture anchors demonstrated greater displacement than titanium suture anchors, the comparable displacement at the distal position as well as the similar load and mechanism of failure make this difference unlikely to be clinically significant.
引用
收藏
页码:2478 / 2483
页数:6
相关论文
共 50 条
  • [21] Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model
    Goschka, Andrew M.
    Hafer, Jason S.
    Reynolds, Kirk A.
    Aberle, Nicholas S., II
    Baldini, Todd H.
    Hawkins, Monica J.
    McCarty, Eric C.
    CLINICAL BIOMECHANICS, 2015, 30 (08) : 808 - 813
  • [22] Anatomic Distal Biceps Tendon Repair With All-Suture Cortical Buttons
    Chalmers, Christen E.
    Mange, Tyler R.
    Wang, Dean
    ARTHROSCOPY TECHNIQUES, 2024, 13 (12):
  • [23] Arthroscopic Bankart repair with knotless all-suture anchors
    Tross, Anna-K.
    Nolte, Philip-C.
    Ruzbarsky, Joseph J.
    Elrick, Bryant P.
    Johannsen, Adam M.
    Millett, Peter J.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2021, 16 (01): : 51 - 53
  • [24] Biomechanical effects of position and angle of insertion for all-suture anchors in arthroscopic Bankart repair
    Lee, Jae-Hoo
    Itami, Yasuo
    Hedayati, Bobak
    Bitner, Benjamin
    McGarry, Michelle H.
    Lee, Thay Q.
    Shin, Sang-Jin
    CLINICAL BIOMECHANICS, 2018, 60 : 45 - 50
  • [25] A biomechanical comparison of EndoButton versus suture anchor repair of distal biceps tendon injuries
    Spang, Jeffrey T.
    Weinhold, Paul S.
    Karas, Spero G.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (04) : 509 - 514
  • [26] Editorial Commentary: Are All-Suture Anchors as Good as Conventional Anchors?
    Barber, F. Alan
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (05):
  • [27] Mechanical properties of all-suture anchors for rotator cuff repair
    Nagra, N. S.
    Zargar, N.
    Smith, R. D. J.
    Carr, A. J.
    BONE & JOINT RESEARCH, 2017, 6 (02): : 82 - 89
  • [28] Rotator Cuff Repair with Knotless All-Suture Medial Row Anchors and Biceps Autograft Augmentation
    Hassebrock, Jeffrey D.
    Mccarthy, Timothy P.
    Sylvia, Stephen M.
    Stokes, Daniel J.
    Shinsako, Kevin K.
    Frank, Rachel M.
    ARTHROSCOPY TECHNIQUES, 2023, 12 (08): : E1361 - E1367
  • [29] Editorial Commentary: All-Suture Anchors, Foam Blocks, and Biomechanical Testing
    Brand, Jefferson C.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (06): : 1122 - 1123
  • [30] Rotator cuff repairs with all-suture tape anchors: no difference in outcomes between with or without all-suture tape anchors
    Rhee, Sung-Min
    Youn, Seung-Min
    Kim, Cheol Hwan
    Chang, Geun-Wu
    Kim, Se Yeon
    Ham, Hyun Joo
    Rhee, Yong Girl
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (09) : 4060 - 4067