Particle size and charge distribution analysis of pharmaceutical aerosols generated by inhalers

被引:25
|
作者
Saini, D.
Biris, A. S. [1 ]
Srirama, P. K.
Mazumder, M. K.
机构
[1] Univ Arkansas, Grad Inst Technol, Little Rock, AR 72204 USA
[2] Univ Arkansas, Dept Appl Sci, Little Rock, AR 72204 USA
[3] St Louis Univ, Dept Mol Microbiol & Immunol, Hlth Sci Ctr, St Louis, MO 63103 USA
关键词
pharmaceutical aerosol; dry powder and metered-dose inhalers; particle size and charge distributions; particle size and charge analyzer;
D O I
10.1080/10837450601166536
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aerosol particles generated by inhalers for respiratory drug delivery acquire electrostatic charge during the dispersion process. The electrostatic charge distribution of the particles can affect the efficiency of drug delivery by influencing both the transport and deposition of inhaled particles in the human lung. To analyze the electrostatic charge acquired by the aerosol particles, two sets of metered-dose inhaler (MDI) and dry powder inhaler (DPI) devices were investigated. Both the particle size and charge distributions were measured simultaneously by using an electrical single-particle aerodynamic relaxation time (E-SPART) analyzer. The analyzer was calibrated with particles of known size, which were generated by a vibrating orifice aerosol generator (TSI Inc.) and charge using the Faraday cup method. The charge distributions of the pharmaceutical aerosols from both the DPI and MDI devices were bipolar in nature. Although the net charge-to-mass ratio was less than 0.2 mu C/g, the individual particles were charged with a relatively high charge: -2 to + 2 mu C/g. The count mean aerodynamic diameter of the aerosols generated from these devices was 3-5 mu m.
引用
下载
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [41] Factors Influencing Aerodynamic Particle Size Distribution of Suspension Pressurized Metered Dose Inhalers
    Poonam Sheth
    Stephen W. Stein
    Paul B. Myrdal
    AAPS PharmSciTech, 2015, 16 : 192 - 201
  • [42] Factors Influencing Aerodynamic Particle Size Distribution of Suspension Pressurized Metered Dose Inhalers
    Sheth, Poonam
    Stein, Stephen W.
    Myrdal, Paul B.
    AAPS PHARMSCITECH, 2015, 16 (01): : 192 - 201
  • [43] Effect of particle size distribution on the triboelectric charge of toners
    Takezawa, S
    Fukuda, M
    Watanuki, T
    Sawatari, N
    IS&T'S NIP13: INTERNATIONAL CONFERENCE ON DIGITAL PRINTING TECHNOLOGIES, PROCEEDINGS, 1997, : 128 - 132
  • [44] PARTICLE SIZE DISTRIBUTION OF TRACE METALS IN AEROSOLS FROM NORTHWEST INDIANA
    NIFONG, GD
    WINCHEST.JW
    BOETTNER, EA
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1970, 51 (10) : 1010 - &
  • [45] Tuning Aerosol Particle Size Distribution of Metered Dose Inhalers Using Cosolvents and Surfactants
    Saleem, Imran Y.
    Smyth, Hugh D. C.
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [46] Effect of particle size distribution on the laminar flame speed of iron aerosols
    Ravi, Aravind
    de Goey, Philip
    van Oijen, Jeroen
    COMBUSTION AND FLAME, 2023, 257
  • [47] Particle size distribution of aerosols and associated heavy metals in kitchen environments
    Sandeep Gupta
    Arun Srivastava
    V. K. Jain
    Environmental Monitoring and Assessment, 2008, 142 : 141 - 148
  • [48] Analysis of particle size distribution by particle tracking
    Finder, C
    Wohlgemuth, M
    Mayer, C
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2004, 21 (05) : 372 - 378
  • [49] Study of Particle Size and Trace Metal Distribution in Atmospheric Aerosols of Islamabad
    Shah, Munir Hussain
    Shaheen, Nazia
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2009, 31 (03): : 427 - 433
  • [50] Comparative particle size distribution of aerosols sampled inside and outside a respirator
    Hery, M
    Villa, M
    Hecht, G
    Hubert, G
    Wrobel, R
    Francois, D
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 1997, 57 (11): : 451 - 456