Particle size and charge distribution analysis of pharmaceutical aerosols generated by inhalers

被引:25
|
作者
Saini, D.
Biris, A. S. [1 ]
Srirama, P. K.
Mazumder, M. K.
机构
[1] Univ Arkansas, Grad Inst Technol, Little Rock, AR 72204 USA
[2] Univ Arkansas, Dept Appl Sci, Little Rock, AR 72204 USA
[3] St Louis Univ, Dept Mol Microbiol & Immunol, Hlth Sci Ctr, St Louis, MO 63103 USA
关键词
pharmaceutical aerosol; dry powder and metered-dose inhalers; particle size and charge distributions; particle size and charge analyzer;
D O I
10.1080/10837450601166536
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aerosol particles generated by inhalers for respiratory drug delivery acquire electrostatic charge during the dispersion process. The electrostatic charge distribution of the particles can affect the efficiency of drug delivery by influencing both the transport and deposition of inhaled particles in the human lung. To analyze the electrostatic charge acquired by the aerosol particles, two sets of metered-dose inhaler (MDI) and dry powder inhaler (DPI) devices were investigated. Both the particle size and charge distributions were measured simultaneously by using an electrical single-particle aerodynamic relaxation time (E-SPART) analyzer. The analyzer was calibrated with particles of known size, which were generated by a vibrating orifice aerosol generator (TSI Inc.) and charge using the Faraday cup method. The charge distributions of the pharmaceutical aerosols from both the DPI and MDI devices were bipolar in nature. Although the net charge-to-mass ratio was less than 0.2 mu C/g, the individual particles were charged with a relatively high charge: -2 to + 2 mu C/g. The count mean aerodynamic diameter of the aerosols generated from these devices was 3-5 mu m.
引用
下载
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [1] Particle charge distribution measurement for commonly generated laboratory aerosols
    Forsyth, B
    Liu, BYH
    Romay, FJ
    AEROSOL SCIENCE AND TECHNOLOGY, 1998, 28 (06) : 489 - 501
  • [2] Particle size distribution of aerosols generated inside vehicles.
    Cheng, YS
    Kenoyer, J
    Glissmeyer, J
    HEALTH PHYSICS, 2002, 82 (06): : S156 - S156
  • [3] Charge and size distribution of medical aerosols
    Kaller, Werner
    Horvath, Helmuth
    Journal of Aerosol Science, 1996, 27 (Suppl 1):
  • [5] Evaluation of different techniques for particle size distribution measurements on laser-generated aerosols
    Kuhn, HR
    Koch, J
    Hargenroder, R
    Niemax, K
    Kalberer, M
    Günther, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (09) : 894 - 900
  • [6] TOXICITY OF PARAQUAT AND DIQUAT AEROSOLS GENERATED BY A SIZE-SELECTIVE CYCLONE - EFFECT OF PARTICLE SIZE DISTRIBUTION
    GAGE, JC
    BRITISH JOURNAL OF INDUSTRIAL MEDICINE, 1968, 25 (04): : 304 - &
  • [7] Composition of aerosols in kitchen and their particle size distribution
    Andrejs, B
    Fauss, J
    Weigl, M
    PROCEEDINGS OF THE SECOND NSF INTERNATIONAL CONFERENCE ON INDOOR AIR HEALTH: TRENDS AND ADVANCES IN RISK ASSESSMENT AND MANAGEMENT, 2001, : 184 - 189
  • [8] PARTICLE-SIZE DISTRIBUTION OF ATMOSPHERIC AEROSOLS
    AHMED, AA
    JOURNAL OF AEROSOL SCIENCE, 1989, 20 (08) : 1115 - 1118
  • [9] OPTIMIZED INHALATION AEROSOLS .2. INERTIAL TESTING METHODS FOR PARTICLE-SIZE ANALYSIS OF PRESSURIZED INHALERS
    PHILLIPS, EM
    BYRON, PR
    FULTS, K
    HICKEY, AJ
    PHARMACEUTICAL RESEARCH, 1990, 7 (12) : 1228 - 1233
  • [10] SIZE AND ELECTROSTATIC CHARGE-DISTRIBUTION FOR ULTRAFINE AEROSOLS
    DAVISON, S
    LIU, CS
    BROUNS, D
    GENTRY, JW
    JOURNAL OF AEROSOL SCIENCE, 1983, 14 (03) : 271 - 276