Contrast-detail characteristic evaluations of several display devices

被引:15
|
作者
Wang, JH [1 ]
Anderson, J [1 ]
Lane, T [1 ]
Stetson, C [1 ]
Moore, J [1 ]
机构
[1] Univ Texas, SW Med Ctr, Dept Radiol, Dallas, TX 75235 USA
关键词
D O I
10.1007/BF03167651
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The contrast-detail characteristic of a display system is a powerful tool for evaluating displayed image quality. It takes into account the physical properties of the display, the psychophysical aspects of the observer, and the viewing conditions. It is a more sensitive measurement of the displayed image quality than a simple Society of Motion Picture and Television (SMPTE) pattern. Yet, it is relatively simple to measure and requires no special equipment or analysis tools. In this presentation, the results of the evaluation of several cathode ray tube (CRT) monitors and a digital projector will be presented. Contrast-detail characteristics of these display devices were measured under various gamma and display settings. The results show excellent intraobserver and interobserver variance (<1 step on the grayscale). Extraneous light, such as room lighting, affects the contrast threshold more severely at low background levels more than at high background. Gamma settings on graphics adapters affect the shapes of the contrast-detail curve for all display types. Gamma settings of approximately 2.0 result in a better contrast threshold for both high and low background brightness. The results show complex differences in contrast-detail characteristics for different display types. The digital projector display not only has significantly worse performance than CRT monitors, but also is affected more by extraneous light. High-brightness monitors with optimal monitor and graphics adapter settings have better performance than color or low-brightness monitors. However, under some settings, the performance of high-brightness monitors is not always better at all object sizes and background levels. Copyright (C) 2000 by W.B. Saunders Company.
引用
收藏
页码:162 / 167
页数:6
相关论文
共 50 条
  • [41] INFLUENCE OF OBSERVER NOISE ON THE SHAPE OF CONTRAST-DETAIL CURVES FOR LIVER CT
    SELTZER, SE
    JUDY, PF
    SWENSSON, RG
    CHAN, K
    NAWFEL, RD
    RADIOLOGY, 1992, 185 : 331 - 331
  • [42] Contrast-detail analysis of three flat panel detectors for digital radiography
    Borasi, Giovanni
    Samei, Ehsan
    Bertolini, Marco
    Nitrosi, Andrea
    Tassoni, Davide
    MEDICAL PHYSICS, 2006, 33 (06) : 1707 - 1719
  • [43] Performance evaluation of a digital mammography unit using a contrast-detail phantom
    Elizalde-Cabrera, J.
    Brandan, M-E
    VII INTERNATIONAL CONGRESS OF ENGINEERING PHYSICS, 2015, 582
  • [44] An automatic evaluation system for contrast-detail phantom images in digital radiography
    Lin, Chuen-Horng
    Lin, Chih-Yang
    Cheng, Yu-Jung
    Chan, Yung-Kuan
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2012, 22 (04) : 214 - 225
  • [45] THE CONTRAST-DETAIL BEHAVIOR OF A PHOTOSTIMULABLE PHOSPHOR BASED COMPUTED RADIOGRAPHY SYSTEM
    MARSHALL, NW
    FAULKNER, K
    BUSCH, HP
    LEHMANN, KJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (12): : 2289 - 2303
  • [46] Contrast-detail evaluation of a full-field digital mammography system
    Darambara, DG
    Taibi, A
    Speller, RD
    Gambaccini, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 870 - 876
  • [47] Determination of contrast-detail curves of mammography systems by automated image analysis
    Karssemeijer, N
    Thijssen, MAO
    DIGITAL MAMMOGRAPHY '96, 1996, 1119 : 155 - 160
  • [48] Contrast-detail evaluation of a full-field digital mammography system
    Darambara, DG
    Taibi, A
    Speller, RD
    Gambaccini, M
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 217 - 221
  • [49] Modified Contrast-Detail Phantom for Determination of the CT Scanners Abilities for Low-Contrast Detection
    Geso, Moshi
    Alghamdi, Salem Saeed
    Tajaldeen, Abdulrahman
    Aljondi, Rowa
    Alghamdi, Hind
    Zailae, Ali
    Mattar, Essam H.
    Tamam, Nissren
    Aljehani, Abdullah
    Omer, Hiba
    Sulieman, Abdelmoneim
    APPLIED SCIENCES-BASEL, 2021, 11 (14):
  • [50] Comparison of contrast-detail characteristics of tomosynthetic reconstruction techniques for digital mammography
    Suryanarayanan, S
    Karellas, A
    Vedantham, S
    Glick, SJ
    D'Orsi, CJ
    Webber, RL
    RADIOLOGY, 1999, 213P : 368 - 369