Contrast-detail evaluation of a full-field digital mammography system

被引:0
|
作者
Darambara, DG [1 ]
Taibi, A [1 ]
Speller, RD [1 ]
Gambaccini, M [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6JA, England
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have been investigating the potential of large-area flat-panel a-Si:H imaging devices for full-field digital mammography. The performance of a clinical mammographic system specially developed to provide geometric direct magnification equipped with an a-Si:H digital detector in conjunction with a series of Gd2O2S:Tb phosphor screens was evaluated in terms of image quality and entrance surface dose by using the contrast-detail CDMAM phantom over a range of exposure levels. We also compared the contrast-detail detectability properties of the a-Si:H-based digital imaging system with those of a conventional screen-film combination. The results from this study reveal the superiority of this prototype a-Si:H-based digital imaging system both in terms of contrast-detail resolution and significant entrance surface dose reduction in comparison with the conventional screen-film combination. These advantages are of particular significance in the breast imaging. Therefore, the combination of a-Si:H digital array with the direct magnification mammography system has the potential to fulfil the image quality requirements for full-field digital mammogarphy and to offer significant improvements in the efficient early detection of breast cancer.
引用
收藏
页码:217 / 221
页数:3
相关论文
共 50 条
  • [1] Contrast-detail evaluation of a full-field digital mammography system
    Darambara, DG
    Taibi, A
    Speller, RD
    Gambaccini, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 870 - 876
  • [2] Contrast-detail comparison of a full-field digital mammography system and a screen-film system
    Rosol, MS
    Niklason, LT
    Venkatakrishnan, V
    Silvenoinnen, H
    Kopans, DB
    Hamberg, LM
    [J]. RADIOLOGY, 1999, 213P : 151 - 151
  • [3] Modification of the CDMAM contrast-detail phantom for image quality evaluation of full-field digital mammography systems
    Bijkerk, KR
    Thijssen, MAO
    Arnoldussen, TJM
    [J]. IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 633 - 640
  • [4] Evaluation of Automatic Exposure Control Performance in Full-Field Digital Mammography Systems using Contrast-Detail Analysis
    Castellanos, Ivan M. Suarez
    Kaczmarek, Richard
    Brunner, Claudia C.
    Heras, Hugo De las
    Liu, Haimo
    Chakrabarti, Kish
    [J]. MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [5] Contrast detail detectability of a full field digital mammography system
    Jung, WC
    Liu, H
    Fajardo, LL
    [J]. BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS, 1999, 3595 : 186 - 192
  • [6] DQE evaluation of a full-field digital mammography system
    Roehrig, H
    Gandhi, K
    Fan, JH
    Poolla, A
    Mimura, S
    [J]. PENETRATING RADIATION SYSTEMS AND APPLICATIONS VI, 2004, 5541 : 141 - 152
  • [7] Performance evaluation of a digital mammography unit using a contrast-detail phantom
    Elizalde-Cabrera, J.
    Brandan, M-E
    [J]. VII INTERNATIONAL CONGRESS OF ENGINEERING PHYSICS, 2015, 582
  • [8] A contrast-detail comparison of computed mammotomography and digital mammography
    McKinley, Randolph L.
    Tornai, Martin P.
    Floyd, Carey E.
    Samei, Ehsan
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [9] Contrast-detail-resolution of full-field digital mammography in comparison to conventional film-screen mammography
    Bick, U
    Diekmann, F
    Grebe, S
    Marth, F
    Juran, R
    Friedrich, M
    [J]. IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 627 - 632
  • [10] Performance evaluation of contrast-detail in full field digital mammography systems using ideal (Hotelling) observer vs. conventional automated analysis of CDMAM images for quality control of contrast-detail characteristics
    Delakis, Ioannis
    Wise, Robert
    Morris, Lauren
    Kulama, Eugenia
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 741 - 746