Influence of pupil dilation on retinal nerve fibre layer measurements with spectral domain OCT

被引:18
|
作者
Massa, G. C. [1 ]
Vidotti, V. G. [1 ]
Cremasco, F. [1 ]
Lupinacci, A. P. C. [1 ]
Costa, V. P. [1 ]
机构
[1] Univ Estadual Campinas, Dept Ophthalmol, BR-01244001 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
OCT tomography; mydriasis; glaucoma; OPTICAL COHERENCE TOMOGRAPHY; THICKNESS MEASUREMENTS; ULTRAHIGH-RESOLUTION; MACULAR THICKNESS; STRATUS OCT; GLAUCOMA; REPRODUCIBILITY; CIRRUS; HEAD;
D O I
10.1038/eye.2010.72
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the influence of pupil dilation on retinal nerve fibre layer (RNFL) measurements with spectral domain optical coherence tomography (OCT). Patients and Methods In total, 29 healthy individuals and 26 glaucoma patients underwent RNFL measurements with the Cirrus HD-OCT Model 4000 (Carl Zeiss Meditec Inc.) before and 30-40 min after pupil dilation with one drop of tropicamide 1%. Average thickness, quadrant thickness, and clock-hour thickness measurements were compared with the paired Student's t-test. We also compared the quality scores of the images obtained pre- and post-pupil dilation. Results Mean ages in the glaucoma and control groups were 58.3 +/- 13.4 and 41.6 +/- 16.4 years respectively (P<0.001). Mean deviation values were -6.96+6.31 dB in the glaucoma group and -1.26+0.79 dB in the control group (P<0.001). Mean RNFL measurements obtained in the glaucoma group were significantly lower than those obtained in the control group (P<0.001). There were no statistically significant differences between mean quality scores obtained before and after dilation neither in the glaucoma group (7.73 +/- 0.92 vs 7.54 +/- 1.10, P=0.232) nor in the control group (8.14 +/- 0.88 vs 8.00 +/- 0.71, P-0.380). There was no statistically significant difference between mean RNFL measurements obtained pre- and post-pupil dilation neither among normal individuals (P>0.05), nor among glaucoma patients (P>0.05). Conclusion The results of this study indicate that RNFL measurements obtained with spectral domain OCT are not influenced by pupil size. Eye (2010) 24, 1498-1502; doi:10.1038/eye.2010.72; published online 28 May 2010
引用
收藏
页码:1498 / 1502
页数:5
相关论文
共 50 条
  • [21] Diagnostic Accuracy of Macular Inner Retinal and Peripapillary Retinal Nerve Fiber Layer Measurements by RTVue Spectral Domain OCT in Early Glaucoma
    Jonnadula, G.
    Senthil, S.
    Addepalli, U. K.
    Rao, H. L.
    Garudadri, C. S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [22] Retinal nerve fiber layer and optic disc measurements by spectral domain OCT: normative values and associations in young adults
    Tariq, Y. M.
    Li, H.
    Burlutsky, G.
    Mitchell, P.
    [J]. EYE, 2012, 26 (12) : 1563 - 1570
  • [23] Retinal nerve fiber layer and optic disc measurements by spectral domain OCT: normative values and associations in young adults
    Y M Tariq
    H Li
    G Burlutsky
    P Mitchell
    [J]. Eye, 2012, 26 : 1563 - 1570
  • [24] Effects of Changing Operators and Instruments on Time-Domain and Spectral-Domain OCT Measurements of Retinal Nerve Fiber Layer Thickness
    Mwanza, Jean-Claude
    Gendy, Mohamed G.
    Feuer, William J.
    Shi, Wei
    Budenz, Donald L.
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2011, 42 (04) : 328 - 337
  • [25] Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia
    Kim, Na Rae
    Lee, Eun Suk
    Seong, Gong Je
    Kang, Sung Yong
    Kim, Ji Hyun
    Hong, Samin
    Kim, Chan Yun
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (08) : 1115 - 1121
  • [26] Influence of Correction of Ocular Magnification on Spectral-Domain OCT Retinal Nerve Fiber Layer Measurement Variability and Performance
    Nowroozizadeh, Sara
    Cirineo, Nila
    Amini, Navid
    Knipping, Shane
    Chang, Ted
    Chou, Tom
    Caprioli, Joseph
    Nouri-Mahdavi, Kouros
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) : 3439 - 3446
  • [27] Comparison of a commercial spectral-domain OCT and swept-source OCT based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness
    Tan, Bingyao
    Chua, Jacqueline
    Harish, Thiyagrajan
    Lau, Amanda
    Gan, Alfred Tau Liang
    Tan, Yar Li
    Wong, Damon W. K.
    Chong, Rachel Shujuan
    Ang, Marcus
    Husain, Rahat
    Schmetterer, Leopold
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (07) : 974 - 979
  • [28] Evaluation of Retinal Nerve Fiber Layer Thickness Measurements for Glaucoma Detection: GDx ECC Versus Spectral-domain OCT
    Bertuzzi, Francesca
    Benatti, Eleonora
    Esempio, Giulia
    Rulli, Eliana
    Miglior, Stefano
    [J]. JOURNAL OF GLAUCOMA, 2014, 23 (04) : 232 - 239
  • [29] Comparison of Retinal Nerve Fiber Layer Measurement Between 2 Spectral Domain OCT Instruments
    Tan, Benjamin B.
    Natividad, Maricel
    Chua, Kia-Chong
    Yip, Leonard W.
    [J]. JOURNAL OF GLAUCOMA, 2012, 21 (04) : 266 - 273
  • [30] Correlation between macular and retinal nerve fibre layer Fourier-domain OCT measurements and visual field loss in chiasmal compression
    M L R Monteiro
    L V F Costa-Cunha
    L P Cunha
    R F S Malta
    [J]. Eye, 2010, 24 : 1382 - 1390