A Markov Random Field Orientation Prior for Electronic Cleansing in CT Colonography

被引:0
|
作者
Krishnan, Karthik [1 ]
Desai, Nasir [2 ]
机构
[1] Samsung, Bangalore, Karnataka, India
[2] Samsung Elect, Suwon, South Korea
关键词
SEGMENTATION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tagging of the bowel content with an oral contrast facilitates CT Colonography with limited bowel preparation. Electronic colon cleansing (ECC) reconstructs the colon lumen, devoid of feces from a CT scan acquired with fecal fluid tagging. A popular method to estimate the stool composition in an image (with the purpose of removing it) is the well-established Expectation Maximization (EM) method. The tagged fluid residue appears as a contrast enhanced region with a largely horizontal interface with air above it. One of the issues is the partial volume (PV) effect that creates voxels with attenuations similar to that of the colon wall at the boundary of air and tagged fluid. We present here, a novel orientation prior formulated as a Markov Random Field that is included as part of the EM tissue segmentation framework to mitigate this PV effect at the air and tagged fluid layer. We show quantitative results on a simple synthetic dataset and qualitative results on patient data that highlight improvements due to the inclusion of the orientation prior.
引用
收藏
页码:2018 / 2021
页数:4
相关论文
共 50 条
  • [41] Fully Automated Electronic Cleansing Using CycleGAN in Computed Tomography Colonography
    Isobe, Yoshitaka
    Teramoto, Atsushi
    Morita, Fujio
    Saito, Kuniaki
    Fujita, Hiroshi
    APPLIED SCIENCES-BASEL, 2022, 12 (21):
  • [42] Technical innovation. Digital subtraction bower cleansing in CT colonography
    Zalis, ME
    Hahn, PF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (03) : 646 - 648
  • [43] Application of Synthetic Sinogram Based Low-Dose CT Simulation and Fold-Preserving Electronic Cleansing Technique for CT Colonography
    Kim, Chang-Won
    Kim, Jong-Hyo
    Lee, Hyunna
    Lee, Jeongjin
    Kim, Se-Hyung
    Yang, Zepa
    Shin, Yeong-Gil
    ABDOMINAL IMAGING: COMPUTATION AND CLINICAL APPLICATIONS, 2013, 8198 : 89 - 98
  • [44] Bowel preparation for CT colonography: Comparison of two different cleansing protocols
    Juchems, Markus S.
    Hoffmann, Martin H. K.
    Schmidt, Stefan A.
    Apostel, Anna
    Brambs, Hans-Juergen
    Aschoff, Andrik J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) : 460 - 464
  • [45] Optimizing bowel contrast for digital subtraction bowel cleansing in CT colonography
    Zalis, ME
    Perumpillichira, J
    Rodrigues, VJ
    Hahn, PF
    Varghese, JC
    RADIOLOGY, 2001, 221 : 578 - 578
  • [46] Sparse Recovery in Magnetic Resonance Imaging With a Markov Random Field Prior
    Panic, Marko
    Aelterman, Jan
    Crnojevic, Vladimir
    Pizurica, Aleksandra
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (10) : 2104 - 2115
  • [47] Glaucoma progression detection using nonlocal Markov random field prior
    Belghith, Akram
    Bowd, Christopher
    Medeiros, Felipe A.
    Balasubramanian, Madhusudhanan
    Weinreb, Robert N.
    Zangwill, Linda M.
    JOURNAL OF MEDICAL IMAGING, 2014, 1 (03)
  • [48] Image Dehazing by Incorporating Markov Random Field with Dark Channel Prior
    XU Hao
    TAN Yibo
    WANG Wenzong
    WANG Guoyu
    Journal of Ocean University of China, 2020, 19 (03) : 551 - 560
  • [49] Image Dehazing by Incorporating Markov Random Field with Dark Channel Prior
    Hao Xu
    Yibo Tan
    Wenzong Wang
    Guoyu Wang
    Journal of Ocean University of China, 2020, 19 : 551 - 560
  • [50] Comparison of Colon Cleansing Quality Between Oral Sodium Phosphate Tablets and Oral Sodium Phosphate Solution Prior to CT Colonography
    Skopic, Amer
    Scott, Tina
    Riddle, Mark S.
    Jensen, Donald W.
    Barlow, Duncan S.
    Cash, Brooks D.
    GASTROENTEROLOGY, 2010, 138 (05) : S517 - S517